Additional Information
- Part Number
- 2736039
- UPC
- 4017918899653
- Country of Origin
- DE
- ETIM
- Group Code : EG000024
- Group Description : PLC's
- Class Description : Fieldbus, decentr. periphery - digital I/O module
- Class Code : EC001599
- Version : 7
Note
- Utilization restriction
- EMC: class A product, see manufacturer's declaration in the download area
Dimensions
- Width
- 60 mm
- Height
- 178 mm
- Depth
- 49.3 mm
- Drill hole spacing
- 168 mm
Fieldline potentials
- Voltage supply UL
- 24 V DC
- Power supply at UL
- 4 A
- Current consumption from UL
- typ. 80 mA
- Current consumption from UL
- max. 100 mA
- Voltage supply US
- 24 V DC
- Power supply at US
- max. 4 A
- Current consumption from US
- typ. 3.5 mA
- Current consumption from US
- max. 700 mA
- Voltage supply UA11
- 24 V DC
- Power supply at UA11
- max. 4 A
- Current consumption at UA11
- typ. 12 mA (plus actuator current)
- Current consumption at UA11
- max. 4 A
- Voltage supply UA12
- 24 V DC
- Power supply at UA12
- max. 4 A
- Current consumption at UA12
- typ. 12 mA (plus actuator current)
- Current consumption at UA12
- max. 4 A
- Voltage supply UA21
- 24 V DC
- Power supply at UA21
- max. 4 A
- Current consumption at UA21
- typ. 12 mA (plus actuator current)
- Current consumption at UA21
- max. 4 A
- Voltage supply UA22
- 24 V DC
- Power supply at UA22
- max. 4 A
- Current consumption at UA22
- typ. 12 mA (plus actuator current)
- Current consumption at UA22
- max. 4 A
Ambient conditions
- Ambient temperature (operation)
- -25°C - 60°C
- Ambient temperature (storage/transport)
- -25°C - 85°C
- Permissible humidity (storage/transport)
- 95 %
- Air pressure (operation)
- 80 kPa - 106 kPa (up to 2000 m above sea level)
- Air pressure (storage/transport)
- 70 kPa - 106 kPa (up to 3000 m above sea level)
- Degree of protection
- IP65/IP67
Environmental Product Compliance
- REACh SVHC
- Lead 7439-92-1
- China RoHS
- Environmentally Friendly Use Period = 50 years
- China RoHS
- For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'
Electrical isolation
- Test section
- 24 V supply (bus logics) / FE 500 V AC 50 Hz 1 s
- Test section
- 24 V supply (bus logics) / 24 V supply (US) 500 V AC 50 Hz 1 s
- Test section
- 24 V supply (bus logics) / Digital outputs (actuator supply) 500 V AC 50 Hz 1 s
- Test section
- 24 V supply (bus logics) / Incoming remote bus 500 V AC 50 Hz 1 s
- Test section
- 24 V supply (bus logics) / Outgoing remote bus 500 V AC 50 Hz 1 s
- Test section
- 24 V supply (US) / FE 500 V AC 50 Hz 1 s
- Test section
- Digital outputs (actuator supply) / FE 500 V AC 50 Hz 1 s
- Test section
- Digital outputs (actuator supply) / 24 V supply (US) 500 V AC 50 Hz 1 s
- Test section
- Digital outputs (actuator supply) / Incoming remote bus 500 V AC 50 Hz 1 s
- Test section
- Incoming remote bus / FE 500 V AC 50 Hz 1 s
- Test section
- Incoming remote bus / Outgoing remote bus 500 V AC 50 Hz 1 s
- Test section
- Outgoing remote bus / FE 500 V AC 50 Hz 1 s
- Test section
- Outgoing remote bus / 24 V supply (US) 500 V AC 50 Hz 1 s
- Test section
- Outgoing remote bus / Digital outputs (actuator supply) 500 V AC 50 Hz 1 s
Digital outputs
- Output name
- Digital outputs
- Connection method
- M12 connector
- Connection technology
- 2, 3-wire
- Number of outputs
- 8
- Protective circuit
- Short-circuit protection
- Output voltage
- 24 V DC
- Maximum output current per channel
- 2 A
Interfaces
- Designation
- INTERBUS
- Designation
- Remote bus
- Connection method
- 2 M12 connectors, B-coded
- Designation connection point
- Copper cable
- Transmission speed
- 500 kbps
- Number of positions
- 5
Standards and Regulations
- Mechanical tests
- Shock in acc. with EN 60068-2-27/IEC 60068-2-27 Load 30g, half sine wave, positive and negative per direction
- Mechanical tests
- Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g in each space direction
- Connection in acc. with standard
- CUL
- Protection class
- III (IEC 61140, EN 61140, VDE 0140-1)
Power supply for module electronics
- Connection method
- M12 connector, (A-coded)
- Designation
- UL
- Supply voltage
- 24 V DC
- Supply voltage range
- 18 V DC - 30 V DC (including ripple)