Additional Information Part Number 1050284 UPC 4055626666501 ETIM Group Code : EG000021 Group Description : Earthing, lightning and surge protection Class Description : Surge protection device for power supply systems Class Code : EC000941 Version : 7 Additional descriptions Note Only usable in IT Systems between L-PE, if the exposed-conductive-parts (bodies) of the equipment of the low-voltage installation is connected...

Additional Information

Part Number
1050284
UPC
4055626666501
ETIM
Group Code : EG000021
Group Description : Earthing, lightning and surge protection
Class Description : Surge protection device for power supply systems
Class Code : EC000941
Version : 7

Additional descriptions

Note
Only usable in IT Systems between L-PE, if the exposed-conductive-parts (bodies) of the equipment of the low-voltage installation is connected to the earthing arrangement of the transformer substation (interconnected earthing arrangement of the HV-transformer substation with the bodies of the LV-installation. RE = RA accordance to IEC 60364-4-442 / VDE 0100-442 Fig. 44D / Example a).

Dimensions

Height
98.7 mm
Width
53.4 mm
Depth
65.7 mm (incl. DIN rail 7.5 mm)
Horizontal pitch
3 Div.

Connection data

Connection method
Screw connection
Screw thread
M5
Tightening torque
3 Nm (1.5 mm² - 16 mm²)
Tightening torque
4.5 Nm (25 mm² - 35 mm²)
Stripping length
16 mm
Conductor cross section flexible
1.5 mm² - 25 mm²
Conductor cross section solid
1.5 mm² - 35 mm²
Conductor cross section AWG
15 - 2
Connection method
Fork-type cable lug
Conductor cross section flexible
1.5 mm² - 16 mm²

Indicator/remote signaling

Switching function
PDT contact
Operating voltage
5 V AC - 250 V AC
Operating voltage
30 V DC
Operating current
5 mA AC - 1.5 A AC
Operating current
1 A DC
Connection method
Plug-in/screw connection via COMBICON
Screw thread
M2
Tightening torque
0.25 Nm
Stripping length
7 mm
Conductor cross section flexible
0.14 mm² - 1.5 mm²
Conductor cross section solid
0.14 mm² - 1.5 mm²
Conductor cross section AWG
28 - 16

Ambient conditions

Degree of protection
IP20 (only when all terminal points are used)
Ambient temperature (operation)
-40°C - 80°C
Ambient temperature (storage/transport)
-40°C - 80°C
Altitude
‰¤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)
5 % - 95 %
Shock (operation)
25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)
5g (10 - 500 Hz / 2.5 h / X, Y, Z)

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1

Protective circuit

Nominal voltage UN
240/415 V AC (TN-C)
Nominal voltage UN
230 V AC (IT)
Nominal frequency fN
50 Hz (60 Hz)
Maximum continuous voltage UC
350 V AC
Rated load current IL
80 A
Residual current IPE
‰¤ 5 µA
Standby power consumption PC
‰¤ 6 mVA
Nominal discharge current In (8/20) µs
10 kA
Maximum discharge current Imax (8/20) µs
20 kA
Impulse discharge current (10/350) µs, charge
1.25 As
Impulse discharge current (10/350) µs, specific energy
1.56 kJ/©
Impulse discharge current (10/350) µs, peak value limp
2.5 kA
Short-circuit current rating ISCCR
25 kA
Voltage protection level Up
‰¤ 1.5 kV
Residual voltage Ures
‰¤ 1.35 kV (at In)
Residual voltage Ures
‰¤ 1.35 kV (at 10 kA)
Residual voltage Ures
‰¤ 1.2 kV (at 5 kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs
‰¤ 1.5 kV
TOV behavior at UT (L-PEN)
415 V AC (5 s / withstand mode)
TOV behavior at UT (L-PEN)
440 V AC (120 min / withstand mode)
Response time tA
‰¤ 100 ns
Max. backup fuse with V-type through wiring
80 A (gG)
Max. backup fuse with branch wiring
125 A (gG)

Standards and Regulations

Standards/regulations
IEC 61643-11 2011
Standards/regulations
EN 61643-11 2012

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products