Additional Information Part Number Fluke 1736/EUS Current Inputs Number of inputs 4, mode selected automatically for attached sensor Input voltage Clamp input: 500 mVrms/50 mVrms; CF 2.8 Rogowski coil input 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range Range 40 mA to 4 A/0.4 A to 40 A with...

Additional Information

Part Number
Fluke 1736/EUS

Current Inputs

Number of inputs
4, mode selected automatically for attached sensor
Input voltage
Clamp input: 500 mVrms/50 mVrms; CF 2.8
Rogowski coil input
150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
Range
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
Bandwidth (-3 dB)
42.5 Hz - 3.5 kHz
Scaling
1:1 and variable

Wireless Connection

Number of inputs
2
Supported modules
Fluke Connect¨ 3000 series
Acquisition
1 reading/s

Data Acquisition

Resolution
16-bit synchronous sampling
Sampling frequency
10.24 kHz at 50/60 Hz, synchronized to mains frequency
Input signal frequency
50/60 Hz (42.5 to 69 Hz)
Circuit types
1-?, 1-? IT, Split phase, 3-? delta, 3-? wye, 3-? wye IT, 3-? wye balanced, 3-? Aron/Blondel (2-element delta), 3-? delta open leg, Currents only (load studies)
Data storage
Internal flash memory (not user replaceable)
Memory size
Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events?

Auxiliary Inputs

Number of inputs
2
Input range
0 to ±10 V dc, 1reading/s
Scale factor
Format: mx + b (gain and offset) user configurable
Displayed units
User configurable (7 characters, for example,¡C, psi, or m/s)

Standards Compliance

Harmonics
IEEE 519 (short time harmonics)
Power quality
IEC 61000-4-30 Class S, IEC62586-1 (PQI-S device)
Power
IEEE 1459
Power quality compliance
EN50160 (for measured parameters)

Voltage Inputs

Number of inputs
4 (3 phases and neutral)
Maximum input voltage
1000 Vrms, CF 1.7
Input impedance
10 M?
Bandwidth (-3 dB)
42.5 Hz - 3.5 kHz
Scaling
1:1 and variable
Measurement category
1000 V CAT III/600 V CAT IV

Basic Interval

Measured parameters
Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
Averaging interval
User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Averaging time min/max values
Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms

Interfaces

USB-A
File transfer via USB flash drive, firmware updatesMax. current: 120 mA
WiFi
File transfer and remote control via direct connection or WiFi infrastructure
Bluetooth
Read auxiliary measurement data from Fluke Connect¨ 3000 series modules (requires 1738 or 1736 upgrade option)
USB-mini
Data download device to PC

Environmental Specifications

Operating temperature
-10¡C to +50¡C (14¡F to 122¡F)
Storage temperature
-20¡C to +60¡C (-4¡F to 140¡F), with battery: -20¡C to +50¡C (-4¡F to 122¡F)
Operating humidity
40¡C to 50¡C (104¡F to 122¡F) max. 45% RH
Operating altitude
2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage altitude
12,000m
Enclosure
IP50 in accordance with EN60529
Vibration
MIL-T-28800E, Type 3, Class III, Style B
Safety
IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V
Electromagnetic compatibility
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Temperature coefficient
0.1 x accuracy specification/¡C

Power Supply

Voltage range
100 V to 240 V using standard power cord (IEC 60320 C7)
Power consumption
Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
Efficiency
³ 68.2% (in accordance with energy efficiency regulations)
Maximum no-load consumption
< 0.3 W only when powered using IEC 60320 input
Mains power frequency
50/60 Hz ±15%
Battery
Li-ion 3.7 V, 9.25 Wh, customer-replaceable
On-battery runtime
Four hours in standard operating mode, up to 5.5 hours in power saving mode
Charging time
< 6 hours

Power Quality Measurements

Measured parameter
Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD
Averaging interval
10 min
Individual harmonics
2nd to 50th harmonic
Total harmonic distortion
Calculated on 50 harmonics
Events
Voltage: dips, swells, interruptions, current: inrush current
Triggered recordings
Waveform of voltage and current (1738)

Demand Interval (Energy Meter Mode)

Measured parameters
Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
Interval
User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off

General Specifications

Color LCD display
4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
Warranty
One-year
Dimensions
Instrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in)
Weight
115 g
Tamper protection
Kensington lock slot
Measuring range
1 to 150 A ac/10 to 1500 A ac
Nondestructive current
100 kA (50/60 Hz)
Intrinsic error at reference condition*
±0.7% of reading
Accuracy 173x + iFlex
±(1% of reading + 0.02% of range)
Temperature coefficient over operating temperature range
0.05% of reading/¡C 0.09% of reading/¡F
Working voltage
1000 V CAT III, 600 V CAT IV
Probe cable length
305 mm (12 in)
Probe cable diameter
7.5 mm (0.3 in)
Minimum bending radius
38 mm (1.5 in)
Output cable length
2 m (6.6 ft)
Probe cable material
TPR
Coupling material
POM + ABS/PC
Output cable
TPR/PVC
Operating temperature
-20¡C to +70¡C (-4¡F to 158¡F) temperature of conductor under test shall not exceed 80¡C (176¡F)
Temperature, non-operating
-40¡C to +80¡C (-40¡F to 176¡F)
Relative humidity, operating
15% to 85% non-condensing
IP rating
IEC 60529:IP50

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products