Additional Information Part Number FLUKE-123B/NA/S UPC 095969814973 Power (125B only) Configurations 1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only) Power factor (PF) Ratio between watts and VA range - 0.00 to 1.00 Watt RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes) || Full scale reading:...

Additional Information

Part Number
FLUKE-123B/NA/S
UPC
095969814973

Power (125B only)

Configurations
1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)
Power factor (PF)
Ratio between watts and VA range - 0.00 to 1.00
Watt
RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes) || Full scale reading: 999 counts
VA
Vrms x Arms || Full scale reading: 999 counts
VA reactive (var)
?((VA)2-W2) || Full scale reading: 999 counts

Power Quality (125B only)

Readings
Watt, VA, var, PF, DPF, Hz
Watt, VA, var ranges (auto)
250 W to 250 MW, 625 MW, 1.56 GW
Watt, VA, var ranges (auto) When selected: total (% r)
±(2% + 6 counts)
Watt, VA, var ranges (auto) When selected: fundamental (% f)
±(4% + 4 counts)
DPF
0.00 to 1.00
PF
0.00 to 1.00, ±0.04
Frequency range
10.0 Hz to 15.0 kHz40.0 Hz to 70.0 Hz
Number of Harmonics
DC to 51
Readings / Cursor readings (fundamental 40 Hz to 70 Hz)
Vrms / Arms /Watt: Each harmonic from fundamental maybe selected for individual readings

Vertical

Frequency response - dc coupled Without probes and test leads (with BB120)
123B: dc to 20 MHz (-3 dB)124B and 125B: dc to 40 MHz (-3 dB)
Frequency response - dc coupled
With STL120-IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB) || With VP41 10:1 Probe: 123B: dc to 20MHz (-3 dB)124B and 125B: dc to 40 MHz (-3 dB)
Frequency response - ac coupled (lf roll off) Without probes and test leads
<10 Hz (-3 dB)
Frequency response - ac coupled (lf roll off)
With STL120-IV 1:1 shielded test leads: <10 Hz (-3 dB) || With VP41 10:1 Probe: <10 Hz (-3 dB)
Rise time, excluding probes, test leads
123B <17.5 ns124B and 125B <8.75 ns
Input impedance Without probes and test leads
1 M?//20 pF
Input impedance With BB120
1 M?//24 pF
Input impedance
With STL120-IV 1:1 shielded test leads: 1 M?//230 pF || With VP41 10:1 Probe: 5 M?//15.5 pF
Sensitivity
5 mV to 200 V/div
Analog bandwidth limiter
10 kHz
Display modes
A, -A, B, -B
Max. input voltage A and B
Direct, with test leads, or with VP41 Probe: 600 Vrms Cat IV, 750 Vrms maximum voltage.
Max. input voltage A and B With BB120
600 Vrms
Max. floating voltage, from any terminal to ground
600 Vrms Cat IV, 750 Vrms up to 400Hz

Ohm (?)

Ranges 123B and 124B
500 ? , 5 k?, 50 k?, 500 k?, 5 M?, 30 M?
Ranges 125B
50 ?, 500 ? , 5 k?, 50 k?, 500 k?, 5 M?, 30 M?
Accuracy
±(0.6% + 5 counts) 50 ? ±(2% + 20 counts)
Full scale reading
50 ? to 5 M? - 5000 counts, 30 M? - 3000 counts
Measurement current
0.5 mA to 50 nA, decreases with increasing ranges
Open circuit voltage
<4 V

Crest factor (CREST)

Range
1 to 10
Full scale reading
90 Counts

Waveform record

Maximum sample rate
400 K sample/s
Size Internal memory
400 M samples Recorded Time
Span internal memory
15 minutes at 500 ?s/div11 hours at 20 ms/div
Record Size SD card
1.5 G samples
Recorded Time Span SD card
11 hours at 500 ?s/div14 days at 20 ms/div
Maximum number of events
64

Decibel (dB)

0 dBV
1 V
0 dBm (600 ? /50 ?)
1 mW referenced to 600 ? or 50 ?
DB on
V dc, V ac, or Vac+dc
Full scale reading
1000 counts

Pulse width (PULSE)

Frequency range
15 Hz (1 Hz) to 30 MHz in continuous autoset
Full scale reading
1000 counts

DC voltage (VDC)

Ranges
500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy
±(0.5% +5 counts)
Common mode rejection (CMRR)
>100 dB @ dc, >60 dB @ 50, 60, or 400 Hz
Full scale reading
5000 counts

Phase

Modes
A to B, B to A
Range
0 to 359 degrees
Resolution
1 degree

Advanced scope functions

Display modes Normal
Captures up to 25 ns glitches and displays analog-like persistence waveform
Display modes Smooth
Suppresses noise from a waveform
Display modes Glitch off
Does not capture glitches between samples
Display modes Envelope
Records and displays the minimum and maximum of waveforms over time
Auto set (Connect-and-View™)
Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.

Continuity (Cont)

Beep
<(30 ? ±5 ?) in 50 ? range
Measurement current
0.5 mA
Detection of shorts of
?1 ms

True-rms voltages (V ac and V ac+dc)

Ranges
500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy for 5% to 100% of range (DC coupled)
DC to 60 Hz (V ac+dc): ±(1% +10 counts) || 1 Hz to 60 Hz (V ac): ±(1% +10 counts)
Accuracy for 5% to 100% of range (AC or dc coupled)
60 Hz to 20 kHz: ±(2.5% +15 counts)
DC rejection (only VAC)
>50 dB
Common mode rejection (CMRR)
>100 dB @ dc || >60 dB @ 50, 60, or 400 Hz
Full scale reading
5000 counts, reading is independent of any signal crest factor.

Diode

Measurement voltage
@0.5 mA: >2.8 V
Measurement voltage @open circuit
<4 V
Measurement current
0.5 mA
Polarity
+ on input A, - on COM

Capacitance (CAP)

Ranges
50 nF, 500 nF, 5 ?F, 50 ?F, 500 ?F
Full scale reading
5000 counts
Measurement current
500 nA to 0.5 mA, increases with increasing ranges

Peak

Modes
Max peak, Min peak, or pk-to-pk
Ranges
500 mV, 5 V, 50 V, 500 V, 2200 V
Accuracy
Accuracy Max peak or Min peak: 5% of full scale
Accuracy Accuracy Peak-to-Peak
10% of full scale
Full scale reading
500 counts

Frequency (Hz)

Ranges
123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz || 124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz
Frequency range
15 Hz (1 Hz) to 50 MHz in continuous autoset
Accuracy @1 Hz to 1 MHz
±(0.5% +2 counts)
Full scale reading
10,000 counts

Amperes (AMP)

With current clamp Ranges
Same as V dc, V ac, V ac+dc, or PEAK
With current clamp Scale factors
0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA
With current clamp Accuracy
Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)
Range
200 °C/div (200 °F/div)
Scale factor
1 mV/°C and 1 mV/°F
Accuracy
As V dc (add temp. probe uncertainty)

Meter readings

Measurement Speed
Maximum 2 measurement/s
Record Size (min, max, average)
2 M readings for 1 channel
Recorded Time Span
2 weeks
Maximum number of events
1024

BusHealth tester (Fluke 125B only)

Type Subtype
Protocol
AS-i
NEN-EN50295
CAN
ISO-11898
Interbus S RS-422
EIA-422
Modbus RS-232
RS-232/EIA-232
Modbus RS-485
RS-485/EIA-485
Foundation Fieldbus H1
61158 type 1, 31.25 kBit
Profibus DP
EIA-485
Profibus PA
61158 type 1

Horizontal

Scope modes
Normal, Single, Roll
Ranges (normal)
Equivalent sampling: 123B: 20 ns to 500 ns/div, || Equivalent sampling: 124B and 125B: 10 ns to 500 ns/div || Real time sampling: 1 ?s to 5 s/div || Single (real time): 1 ?s to 5 s/div
Ranges (normal) Roll (real time)
1s to 60 s/div
Sampling rate (for both channels simultaneously)
Equivalent sampling (repetitive signals): Up to 4 GS/s || Real time sampling 1 ?s to 60 s/div: 40 MS/s

Environmental

Environmental
MIL-PRF-28800F, Class 2
Temperature Battery Operation
0 to 40 °C (32 to 104 °F)
Temperature Power Adapter Operation
0 to 50 °C (32 to 122 °F)
Temperature Storage
-20 to 60 °C (-4 to 140 °F)
Humidity (Operating)
@ 0 to 10 °C (32 to 50 °F): Non-condensing || @ 10 to 30 °C (50 to 86 °F): 95% || @ 30 to 40 °C (86 to 104 °F): 75% || @ 40 to 50 °C (104 to 122 °F): 45%
Storage
@ -20 to 60 °C (-4 to 140 °F): Non-condensing
Altitude
Operating at 3 km (10,000 feet): CAT III 600 V || Operating at 2 km (6,600 feet): CAT IV 600 V
Altitude Storage
12 km (40,000 feet)
EMC electromagnetic compatibility International
IEC 61326-1: Industrial, CISPR 11:  Group 1, Class A
EMC electromagnetic compatibility Korea (KCC)
Class A Equipment (Industrial Broadcasting & Communication Equipment)
EMC electromagnetic compatibility USA (FCC)
47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Wireless radio with adapter Frequency range
2412 MHz to 2462 MHz
Wireless radio with adapter Output power
<100 mW
Enclosure protection
IP51, ref: EN/IEC60529
Safety General
IEC 61010-1: Pollution Degree 2
Safety Measurement
IEC 61010-2-033: CAT IV 600 V/CAT III 750 V
Max. input voltage input A and B
Direct on input or with leads: 600 Vrms CAT IV for derating || Max. floating voltage from any terminal to ground: 600 Vrms Cat IV, 750 Vrms up to 400 Hz
Max. input voltage input A and B With Banana-to-BNC Adapter BB120
600 Vrms for derating

Cursor Readout (124B and 125B)

Sources
A, B
Single vertical line
Average, min and max readout || Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD) || Min, max and time from start of readout (in RECORDER mode; instrument in HOLD) || Harmonics values in POWER QUALITY mode.
Dual vertical lines
Peak-peak, time distance and reciprocal time distance readout || Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)
Dual horizontal lines
High, low and peak-peak readout
Rise or fall time
Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only possible in single channel mode)
Accuracy
As oscilloscope accuracy

RPM

Max reading
50.00 kRPM
Accuracy
±(0.5% +2 counts)

Advanced meter functions

Zero Set
Set actual value to reference
AutoHold (on A)
Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.
Fixed decimal point
Activated by using attenuation keys

Duty cycle (PULSE)

Range
2% to 98%
Frequency range
15 Hz (1 Hz) to 30 MHz in continuous autoset

Trigger

Screen update
Free run, on trigger
Source
A, B
Sensitivity A and B
@ DC to 5 MHz: 0.5 divisions or 5 mV || @ 40 MHz: 123B: 4 divisions || @ 40 MHz: 124B and 125B: 1.5 divisions || @ 60 MHz: 123B: N/A || @ 60 MHz: 124B and 125B: 4 divisions
Slope
Positive, negative

Vpwm

Purpose
To measure on pulse width modulated signals, like motor drive inverter outputs
Principle
Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
Accuracy
As Vrms for sinewave signals

Miscellaneous

Display Type
5.7-inch color active matrix TFT
Display Resolution
640 x 480 pixels
Waveform Display
Vertical: 10 div of 40 pixels

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products