FLUKE 9143-C-156-Dropship Automation

FLUKE 9143-C-156

SKU: DA-184308
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number 9143-C-156 UPC 095969419925 Base Unit Specifications Hysteresis 0.03 Stability ±0.02°C at 33°C ±0.02°C at 200°C±0.03°C at 350°C Computer interface RS-232 and 9930 Interface-it control software included Operating conditions 0°C to 50°C, 0% to 90% RH (non-condensing) Resolution 0.01° Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes) ±0.015°C Full Range Immersion (well)...

Additional Information

Part Number
9143-C-156
UPC
095969419925

Base Unit Specifications

Hysteresis
0.03
Stability
±0.02°C at 33°C ±0.02°C at 200°C±0.03°C at 350°C
Computer interface
RS-232 and 9930 Interface-it control software included
Operating conditions
0°C to 50°C, 0% to 90% RH (non-condensing)
Resolution
0.01°
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes)
±0.015°C Full Range
Immersion (well) depth
150 mm (5.9 in)
Power requirements
100 V to 115 V (±10%), 50/60 Hz, 1400 W 230 V (±10%), 50/60 Hz, 1800 W
Size (H x W x D)
290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
Weight
7.3 kg (16 lb)
Insert OD
25.3 mm (1.00 in)
Heating time
5 min: 33°C to 350°C
Cooling time
32 min: 350°C to 33°C 14 min: 350°C to 100°C
Environmental conditions (for all specifications except temperature range)
13°C to 33°C
Radial uniformity
±0.01°C at 33°C ±0.015°C at 200°C±0.02°C at 350°C
Display
LCD,°C or°F user-selectable
Axial uniformity at 40 mm (1.6 in)
±0.04°C at 33°C ±0.1°C at 200°C±0.2°C at 350°C
Display accuracy
±0.2°C Full Range
Temperature range at 23°C
33°C to 350°C (91°F to 662°F)

P specifications

Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires.
Internal cold junction compensation accuracy
±0.35°C (ambient of 13°C to 33°C)
TC connection
Small connectors
RTD connection
4 terminal input
Reference characterizations
ITS-90, CVD, IEC-751, Resistance
RTD resistance accuracy¡
0 ohms to 25 ohms: ±0.002 ohms 25 ohms to 400 ohms: ±80 ppm of reading
RTD measurement capability
4-wire RTD (2-,3-wire RTD w\ Jumpers only)
Built-in TC thermometer readout accuracy
Type J: ±0.7°C at 660°C Type K: ±0.8°C at 660°C Type T: ±0.8°C at 400°C Type E: ±0.7°C at 660°C Type R: ±1.4°C at 660°C Type S: ±1.5°C at 660°C Type M: ±1.4°C at 660°C Type L: ±0.7°C at 660°C Type U: ±0.75°C at 600°C Type N: ±0.9°C at 660°C Type C: ±1.1°C at 660°C
MA connection
2 terminal input
RTD characterizations
PT-100 (385),(JIS),(3926), NI-120, Resistance
RTD resistance range
0 ohms to 400 ohms
MA range
Cal 4-22 mA, Spec 4-24 mA
TC millivolt range
“10 mV to 75 mV
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
±0.005% of range per°C
Reference measurement capability
4-wire
Built-in reference thermometer readout accuracy (4-Wire reference probe)1
±0.010°C at -25°C ±0.015°C at 0°C ±0.020°C at 50°C ±0.025°C at 150°C ±0.030°C at 200°C ±0.040°C at 350°C ±0.050°C at 420°C ±0.070°C at 660°C
Reference resistance accuracy2
0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading
Built-in RTD thermometer readout accuracy
NI-120: ±0.015°C at 0°C PT-100 (385): ±0.02°C at 0°C PT-100 (3926): ±0.02°C at 0°C PT-100 (JIS): ±0.02°C at 0°C
Voltage accuracy
0.025% of reading + 0.01 mV
Reference resistance range
0 ohms to 400 ohms
Loop power function
24 V DC loop power
Built-in mA readout accuracy
0.02% of reading + 2 mV
Reference probe connection
6-pin Din with Infocon Technology

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.