FLUKE 9142-DW-P-156-Dropship Automation

FLUKE 9142-DW-P-156

SKU: DA-719999
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number 9142-DW-P-156 UPC 095969419628 P Specifications Reference resistance range 0 ohms to 400 ohms Reference resistance accuracy2 0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading RTD resistance range 0 ohms to 400 ohms Built-in TC thermometer readout accuracy Type J: ±0.7°C at 660°C Type K: ±0.8°C at 660°C Type...

Additional Information

Part Number
9142-DW-P-156
UPC
095969419628

P Specifications

Reference resistance range
0 ohms to 400 ohms
Reference resistance accuracy2
0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading
RTD resistance range
0 ohms to 400 ohms
Built-in TC thermometer readout accuracy
Type J: ±0.7°C at 660°C Type K: ±0.8°C at 660°C Type T: ±0.8°C at 400°C Type E: ±0.7°C at 660°C Type R: ±1.4°C at 660°C Type S: ±1.5°C at 660°C Type M: ±1.4°C at 660°C Type L: ±0.7°C at 660°C Type U: ±0.75°C at 600°C Type N: ±0.9°C at 660°C Type C: ±1.1°C at 660°C
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires.
RTD resistance accuracy2
0 ohms to 25 ohms: ±0.002 ohms 25 ohms to 400 ohms: ±80 ppm of reading
RTD characterizations
PT-100 (385),(JIS),(3926), NI-120, Resistance
Voltage accuracy
0.025% of reading + 0.01 mV
Built-in RTD thermometer readout accuracy
NI-120: ±0.015°C at 0°C PT-100 (385): ±0.02°C at 0°C PT-100 (3926): ±0.02°C at 0°C PT-100 (JIS): ±0.02°C at 0°C
TC connection
Small connectors
Built-in reference thermometer readout accuracy (4-Wire Reference Probe)1
±0.010°C at -25°C ±0.015°C at 0°C±0.020°C at 50°C±0.025°C at 150°C±0.030°C at 200°C±0.040°C at 350°C±0.050°C at 420°C ±0.070°C at 660°C
Loop power function
24 V DC loop power
Reference characterizations
ITS-90, CVD, IEC-751, Resistance
Reference measurement capability
4-wire
TC millivolt range
–10 mV to 75 mV
MA connection
2 terminal input
RTD connection
4 terminal input
Built-in mA readout accuracy
0.02% of reading + 2 mV
Internal cold junction compensation accuracy
±0.35°C (ambient of 13°C to 33°C)
RTD measurement capability
4-wire RTD (2-,3-wire RTD w/ Jumpers only)
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
±0.005% of range per°C
Reference probe connection
6-pin Din with Infocon Technology
MA range
Cal 4-22 mA, Spec 4-24 mA

Base Unit Specifications

Environmental conditions (for all specifications except temperature range)
13°C to 33°C
Temperature range at 23°C
–25°C to 150°C (–13°F to 302°F)
Immersion (well) Depth
150 mm (5.9 in)
Insert OD
30 mm (1.18 in)
Weight
8.16 kg (18 lb)
Computer interface
RS-232 and 9930 Interface-it control software included
Display accuracy
±0.2°C full range
Hysteresis
0.025
Radial uniformity
±0.01°C full range
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes)
±0.006°C full range
Operating conditions
0°C to 50°C, 0% to 90% RH (non-condensing)
Display
LCD,°C or°F user-selectable
Cooling time
15 min: 23°C to –25°C 25 min: 150°C to –23°C
Axial uniformity at 40 mm (1.6 in)
±0.05°C full range
Resolution
0.01°
Size (H x W x D)
290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
Heating time
16 min: 23°C to 140°C 23 min: 23°C to 150°C 25 min: –25°C to 150°C
Stability
±0.01°C full range
Power requirements
100 V to 115 V (±10%) 50/60 Hz, 635 W 230 V (±10%) 50/60 Hz, 575 W

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.