Additional Information Part Number 277489 Specifications Contact configuration 1 NC Terminal capacity (flexible with ferrule) 1 x (0.75 - 1.5) mm² Rated operational current for specified heat dissipation (In) 9 A 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. Rated operational power at AC-3, 380/400 V, 50 Hz 4 kW Conventional thermal...

Additional Information

Part Number
277489

Specifications

Contact configuration
1 NC
Terminal capacity (flexible with ferrule)
1 x (0.75 - 1.5) mm²
Rated operational current for specified heat dissipation (In)
9 A
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Rated operational power at AC-3, 380/400 V, 50 Hz
4 kW
Conventional thermal current ith (3-pole, enclosed)
18 A
Rated operational power at AC-4, 380/400 V, 50 Hz
2.5 kW
Rated operational current (Ie) at AC-4, 440 V
6 A
Rated control supply voltage (Us) at AC, 50 Hz - min
24 V
10.4 Clearances and creepage distances
Meets the product standard's requirements.
Number of contacts (normally closed) as main contact
0
Short-circuit current rating (high fault at 480 V)
65 kA, CB, SCCR (UL/CSA)
Conventional thermal current ith at 55°C (3-pole, open)
21 A
Rated operational power (NEMA)
3.7 kW
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
Ambient storage temperature - min
40°C
Fitted with:
Mirror contact
Rated breaking capacity at 380/400 V
90 A
Short-circuit current rating (basic rating)
60 A, max. CB, SCCR (UL/CSA)
Rated control supply voltage (Us) at AC, 50 Hz - max
24 V
Rated breaking capacity at 660/690 V
50 A
Rated operational current (Ie) at DC-1, 220 V
15 A
Special purpose rating of elevator control
2 HP, 240 V 60 Hz 3-ph, (UL/CSA)
Ambient operating temperature - max
60°C
Assigned motor power at 115/120 V, 60 Hz, 1-phase
.5 HP
Rated operational power at AC-4, 440 V, 50 Hz
3 kW
Electrical connection type of main circuit
Spring clamp connection
Number Of Poles
Three-pole
Ambient operating temperature - min
-25°C
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
Terminal capacity (flexible)
2 x (0.75 - 2.5) mm²
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
Application
Contactors for Motors
Operating frequency
9000 mechanical Operations/h (AC operated)
Voltage type
AC
Short-circuit protection rating (type 1 coordination) at 400 V
35 A gG/gL
Product category
Contactors
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V
6 A
Power consumption, pick-up, 50 Hz
25 VA, Dual-frequency coil in a cold state and 1.0 x Us
Heat dissipation capacity Pdiss
0 W
Assigned motor power at 460/480 V, 60 Hz, 3-phase
5 HP
Special purpose rating of tungsten incandescent lamps
14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Switching time (AC operated, make contacts, opening delay) - min
9 ms
Continuous ampere rating
20 A
Rated operational current (Ie) at AC-4, 500 V
5 A
Rated operational power at AC-3, 240 V, 50 Hz
3 kW
Terminal capacity (solid/stranded AWG)
18 - 14
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Degree of protection
IP20
Overvoltage category
III
Switching time (AC operated, make contacts, opening delay) - max
18 ms
Ambient storage temperature - max
80°C
Pollution degree
3
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
22 A
Power consumption, pick-up, 60 Hz
27 VA, Dual-frequency coil in a cold state and 1.0 x Us
Switching time (AC operated, make contacts, closing delay) - max
21 ms
Rated impulse withstand voltage (Uimp)
8000 V AC
Rated operational power at AC-4, 660/690 V, 50 Hz
3.6 kW
Conventional thermal current ith (1-pole, enclosed)
45 A
Rated operational current (Ie) at AC-3, 660 V, 690 V
5 A
Type
Full voltage reversing small contactor
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.7 Inscriptions
Meets the product standard's requirements.
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
9 A
Switching time (AC operated, make contacts, closing delay) - min
15 ms
Short-circuit protection rating (type 2 coordination) at 400 V
20 A gG/gL
Special purpose rating of ballast electrical discharge lamps
18 A (600V 60Hz 3phase, 347V 60Hz 1phase)
Number of auxiliary contacts (normally open contacts)
0
Special purpose rating of definite purpose rating
9 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Shock resistance
3.4 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
Rated operational current (Ie) at DC-1, 110 V
20 A
Assigned motor power at 230/240 V, 60 Hz, 3-phase
3 HP
Drop-out voltage
AC operated: 0.6 - 0.3 x UC, AC operated
Power consumption, sealing, 60 Hz
3.3 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Resistance per pole
2.5 m©
Ambient operating temperature (enclosed) - min
25°C
Stripping length (control circuit cable)
10 mm
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Special purpose rating of refrigeration control (CSA only)
60 A, LRA 480 V 60 Hz 3phase; (CSA)
Amperage Rating
170A
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
Stripping length (main cable)
10 mm
Ambient operating temperature (enclosed) - max
40°C
Special purpose rating of resistance air heating
18 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Rated control supply voltage (Us) at DC - min
0 V
Short-circuit current rating (high fault at 600 V)
30/100 kA, Fuse, SCCR (UL/CSA)
Frequency rating
50-60 Hz
10.8 Connections for external conductors
Is the panel builder's responsibility.
Number of main contacts (normally open contact)
3
Rated breaking capacity at 220/230 V
90 A
Rated operational current (Ie) at AC-4, 400 V
6 A
Terminals
Spring loaded terminals
Short-circuit protection rating (type 2 coordination) at 690 V
16 A gG/gL
Assigned motor power at 575/600 V, 60 Hz, 3-phase
7.5 HP
Protection
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Power consumption, sealing, 50 Hz
1.2 W, Dual-frequency coil in a cold state and 1.0 x Us
HP rating - max
0.5, 1.5/ 3, 3, 5, 7.5 hp (1/3PH @120, 240/208,240,480,600 V)
Rated breaking capacity at 500 V
70 A
Rated operational power at AC-3, 415 V, 50 Hz
5.5 kW
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Emitted interference
According to EN 60947-1
Connection to SmartWire-DT
No
Static heat dissipation, non-current-dependent Pvs
1.4 W
Rated control supply voltage (Us) at DC - max
0 V
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
Utilization category
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Coil voltage
24 Vac, 50-60 Hz
Rated operational current (Ie) at AC-3, 440 V
9 A
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
Safe isolation
400 V AC, Between coil and contactss, According to EN 61140
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Number of contacts (normally closed contacts)
1
Heat dissipation per pole, current-dependent Pvid
.2 W
Switching capacity (auxiliary contacts, general use)
1 A, 250 V DC, (UL/CSA)
Operating temperature - min
-25°C
Rated operational current (Ie) at AC-4, 660 V, 690 V
4.5 A
Equipment heat dissipation, current-dependent Pvid
0 W
Assigned motor power at 200/208 V, 60 Hz, 3-phase
3 HP
Pick-up voltage
0.8 - 1.1 V AC x Uc
Suitable for
Also motors with efficiency class IE3
Operation
Reversing
Terminal capacity (solid)
2 x (0.75 - 2.5) mm²
Number of auxiliary contacts (normally closed contacts)
1
Interference immunity
According to EN 60947-1
Power consumption
4 kW
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
Operating temperature - max
60°C
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
Lifespan, mechanical
7,000,000 Operations (Coil 50/60 Hz)
Short-circuit protection rating (type 1 coordination) at 690 V
20 A gG/gL
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)
112 A
Rated operational power at AC-4, 240 V, 50 Hz
1.6 kW
Rated operational power at AC-4, 500 V, 50 Hz
2.8 kW
Voltage rating
400 V
Number of contacts
1 NC
Rated operational current (Ie) at DC-1, 60 V
20 A
Rated operational power at AC-4, 220/230 V, 50 Hz
1.5 kW
Rated operational voltage (Ue) at AC - max
690 V
Rated control supply voltage (Us) at AC, 60 Hz - min
24 V
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Switching capacity (main contacts, general use)
20 A, Maximum motor rating (UL/CSA)
Rated operational current (Ie) at AC-3, 500 V
7 A
Assigned motor power at 230/240 V, 60 Hz, 1-phase
1.5 HP
Screwdriver size
3.5 mm, Spring-loaded terminals
Duty factor
100 %
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
9 A
Conventional thermal current ith of main contacts (1-pole, open)
50 A
Rated control supply voltage (Us) at AC, 60 Hz - max
24 V
Arcing time
10 ms
Rated operational power at AC-4, 415 V, 50 Hz
2.8 kW
Switching capacity (auxiliary contacts, pilot duty)
P300, DC operated (UL/CSA)
Rated insulation voltage (Ui)
690 V

General

Model Code
DILMC9-01(24V50/60HZ)
EAN
4015082774899
Product Length/Depth
75 mm
Product Height
68 mm
Product Width
45 mm
Product Weight
.227 kg
Warranty
1 year
Certifications
CSA Certified
Catalog Notes
Auxiliary current, coil, and main current terminals with spring-cage connection technology|Contacts according to EN 50012|IE3-ready devices are identified by the logo on their packaging.

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products