Additional Information Part Number 255907 Specifications Rated operational current for specified heat dissipation (In) 100 A 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. Rated operational current (Ie) at DC-23A, 24 V 50 A Rated operational power at AC-3, 380/400 V, 50 Hz 37 kW 10.4 Clearances and creepage distances Meets the...

Additional Information

Part Number
255907

Specifications

Rated operational current for specified heat dissipation (In)
100 A
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Rated operational current (Ie) at DC-23A, 24 V
50 A
Rated operational power at AC-3, 380/400 V, 50 Hz
37 kW
10.4 Clearances and creepage distances
Meets the product standard's requirements.
Mounting method
Surface mounting
Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)
760 A
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
Fitted with:
Red rotary handle and yellow locking ring
Degree of protection (front side)
IP65
Short-circuit current rating (basic rating)
10 kA, SCCR (UL/CSA)
Rated operational current (Ie) at DC-23A, 120 V
25 A
Rated conditional short-circuit current (Iq)
4 kA
Actuator type
Door coupling rotary drive
Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)
950 A
Ambient operating temperature - max
40°C
Assigned motor power at 115/120 V, 60 Hz, 1-phase
5 HP
Features
Version as maintenance-/service switch
Electrical connection type of main circuit
Screw connection
Rated breaking capacity at 500 V (cos phi to IEC 60947-3)
880 A
Number of poles
Three-pole
Ambient operating temperature - min
-25°C
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
Rated uninterrupted current (Iu)
100 A
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
Operating frequency
1200 Operations/h
Product Category
Main switch
Number of contacts in series at DC-23A, 48 V
2
Rated operational current (Ie) at DC-23A, 48 V
50 A
Terminal capacity
1 x (1.5 - 25) mm², flexible with ferrules to DIN 46228
Number of contacts in series at DC-23A, 24 V
1
Heat dissipation capacity Pdiss
0 W
Assigned motor power at 460/480 V, 60 Hz, 3-phase
60 HP
Assigned motor power at 200/208 V, 60 Hz, 1-phase
10 HP
Rated operational current (Ie) at AC-23A, 400 V, 415 V
100 A
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Overvoltage category
III
Degree of protection
IP65
Actuator color
Red
Rated operational current (Ie) at AC-23A, 230 V
100 A
Pollution degree
3
Rated operational power at AC-23A, 500 V, 50 Hz
55 kW
Rated impulse withstand voltage (Uimp)
6000 V AC
Switching power at 400 V
55 kW
Voltage per contact pair in series
60 V
Functions
Interlockable
Tightening torque
3 Nm, Screw terminals
Rated operational power at AC-3, 690 V, 50 Hz
37 kW
Rated operational current (Ie) at AC-3, 660 V, 690 V
23.8 A
Type
Main switch
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
UV resistance only in connection with protective shield.
10.2.7 Inscriptions
Meets the product standard's requirements.
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
71 A
Number of auxiliary contacts (normally open contacts)
1
Shock resistance
15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
Assigned motor power at 230/240 V, 60 Hz, 3-phase
25 HP
Ambient operating temperature (enclosed) - min
-25°C
Rated operational power at AC-23A, 400 V, 50 Hz
55 kW
Rated operational current (Ie) at AC-23A, 500 V
96 A
Rated operational current (Ie) at DC-23A, 60 V
50 A
Rated operational power at AC-23A, 220/230 V, 50 Hz
30 kW
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
Ambient operating temperature (enclosed) - max
40°C
Rated operational current (Ie) at AC-21, 440 V
100 A
Rated operational voltage (Ue) at AC - min
690 V
10.8 Connections for external conductors
Is the panel builder's responsibility.
Screw size
M5, Terminal screw
Assigned motor power at 575/600 V, 60 Hz, 3-phase
75 HP
Load rating
1.3 x I‚‘ (with intermittent operation class 12, 60 % duty factor)
Rated operational current (Ie) at AC-23A, 690 V
68 A
Rated permanent current at AC-21, 400 V
100 A
Rated operational power at AC-3, 415 V, 50 Hz
37 kW
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Device construction
Complete device in housing
Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)
740 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
Safe isolation
440 V AC, Between the contacts, According to EN 61140
Mounting position
As required
Safety parameter (EN ISO 13849-1)
B10d values as per EN ISO 13849-1, table C.1
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated operational power at AC-23A, 690 V, 50 Hz
55 kW
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Heat dissipation per pole, current-dependent Pvid
7.5 W
Switching capacity (auxiliary contacts, general use)
10A, IU, (UL/CSA)
Uninterrupted current
Rated uninterrupted current Iu is specified for max. cross-section.
Equipment heat dissipation, current-dependent Pvid
0 W
Assigned motor power at 200/208 V, 60 Hz, 3-phase
20 HP
Suitable for
Ground mounting
Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)
520 A
Accessories
Auxiliary contact or neutral conductor fitted by user.
Number of auxiliary contacts (normally closed contacts)
1
Rated operational current (Ie) at DC-1, load-break switches l/r = 1 ms
100 A
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
Lifespan, mechanical
100,000 Operations
Number of contacts in series at DC-23A, 60 V
2
Control circuit reliability
1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
Rated short-time withstand current (Icw)
2 kA, Contacts, 1 second
Number of auxiliary contacts (change-over contacts)
0
Rated operational voltage (Ue) at AC - max
690 V
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Switching capacity (main contacts, general use)
100 A, If used with neutral conductor IU = max. 90 A, Rated uninterrupted current max. (UL/CSA)
Number of contacts in series at DC-23A, 120 V
3
Rated operational current (Ie) at AC-3, 500 V
65 A
Assigned motor power at 230/240 V, 60 Hz, 1-phase
15 HP
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
71 A
Short-circuit protection rating
100 A gG/gL, Fuse, Contacts
Switching capacity (auxiliary contacts, pilot duty)
A600 (UL/CSA)

General

Model Code
P3-100/I5/SVB/HI11-NA
EAN
4015082559076
Product Length/Depth
169 mm
Product Height
280 mm
Product Width
200 mm
Product Weight
1.54 kg
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Rated Short-time Withstand Current (Icw) for a time of 1 second|UL/CSA

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products