- Contact configuration
- 1 NO
- Terminal capacity (flexible with ferrule)
- 1 x (0.75 - 16) mm², Main cables
- Rated operational current for specified heat dissipation (In)
- 32 A
- 10.11 Short-circuit rating
- Is the panel builder's responsibility. The specifications for the switchgear must be observed.
- Rated operational power at AC-1, 380/400 V, 50 Hz
- 20 kW
- Rated operational power at AC-3, 380/400 V, 50 Hz
- 7.5 kW
- Conventional thermal current ith (3-pole, enclosed)
- 27 A
- Rated operational power at AC-4, 380/400 V, 50 Hz
- 7 kW
- Rated control supply voltage (Us) at AC, 50 Hz - min
- 230 V
- 10.4 Clearances and creepage distances
- Meets the product standard's requirements.
- Number of contacts (normally closed) as main contact
- 0
- Short-circuit current rating (high fault at 480 V)
- 125/70 A, Class J, max. Fuse, SCCR (UL/CSA)
- Conventional thermal current ith at 55°C (3-pole, open)
- 29 A
- Rated operational power (NEMA)
- 11 kW
- 10.2.3.1 Verification of thermal stability of enclosures
- Meets the product standard's requirements.
- Ambient storage temperature - min
- 40°C
- Rated breaking capacity at 380/400 V
- 180 A
- Short-circuit current rating (basic rating)
- 125 A, max. CB, SCCR (UL/CSA)
- Rated control supply voltage (Us) at AC, 50 Hz - max
- 230 V
- Rated breaking capacity at 660/690 V
- 120 A
- Rated operational current (Ie) at DC-1, 220 V
- 32 A
- Special purpose rating of elevator control
- 5 HP, 240 V 60 Hz 3-ph, (UL/CSA)
- Ambient operating temperature - max
- 60°C
- Assigned motor power at 115/120 V, 60 Hz, 1-phase
- 2 HP
- Electrical connection type of main circuit
- Screw connection
- Number Of Poles
- Four-pole
- Ambient operating temperature - min
- -25°C
- 10.6 Incorporation of switching devices and components
- Does not apply, since the entire switchgear needs to be evaluated.
- 10.2.6 Mechanical impact
- Does not apply, since the entire switchgear needs to be evaluated.
- 10.3 Degree of protection of assemblies
- Does not apply, since the entire switchgear needs to be evaluated.
- Application
- Contactors for 4 pole electric consumers
- Operating frequency
- 5000 mechanical Operations/h (DC operated)
- Voltage type
- AC
- Short-circuit protection rating (type 1 coordination) at 400 V
- 63 A gG/gL
- Product category
- Contactors
- Rated operational power at AC-1, 500 V, 50 Hz
- 26 kW
- Power consumption, pick-up, 50 Hz
- 50 VA, Dual-frequency coil in a cold state and 1.0 x Us
- Heat dissipation capacity Pdiss
- 0 W
- Assigned motor power at 460/480 V, 60 Hz, 3-phase
- 15 HP
- Special purpose rating of tungsten incandescent lamps
- 40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
- Switching time (AC operated, make contacts, opening delay) - min
- 8 ms
- Continuous ampere rating
- 32 A
- Rated operational power at AC-3, 240 V, 50 Hz
- 5.5 kW
- Terminal capacity (solid/stranded AWG)
- 18 - 6, Main cables
- 10.9.2 Power-frequency electric strength
- Is the panel builder's responsibility.
- Degree of protection
- IP00
- Overvoltage category
- III
- Rated operational power at AC-1, 440 V, 50 Hz
- 23 kW
- Switching time (AC operated, make contacts, opening delay) - max
- 14 ms
- Ambient storage temperature - max
- 80°C
- Pollution degree
- 3
- Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
- 32 A
- Power consumption, pick-up, 60 Hz
- 40 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
- Switching time (AC operated, make contacts, closing delay) - max
- 22 ms
- Rated impulse withstand voltage (Uimp)
- 8000 V AC
- Connection
- Screw connection
- Tightening torque
- 3 Nm, Screw terminals, Main cables
- Conventional thermal current ith (1-pole, enclosed)
- 76 A
- Rated operational current (Ie) at AC-3, 660 V, 690 V
- 12 A
- Type
- Full voltage non-reversing small contactor
- 10.2.2 Corrosion resistance
- Meets the product standard's requirements.
- 10.2.4 Resistance to ultra-violet (UV) radiation
- Meets the product standard's requirements.
- 10.2.7 Inscriptions
- Meets the product standard's requirements.
- Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
- 18 A
- Number of contacts (normally open contacts)
- 1
- Switching time (AC operated, make contacts, closing delay) - min
- 16 ms
- Short-circuit protection rating (type 2 coordination) at 400 V
- 35 A gG/gL
- Special purpose rating of ballast electrical discharge lamps
- 40 A (480V 60Hz 3phase, 277V 60Hz 1phase)
- Number of auxiliary contacts (normally open contacts)
- 1
- Special purpose rating of definite purpose rating
- 25 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
- Shock resistance
- 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
- Rated operational current (Ie) at DC-1, 110 V
- 32 A
- Assigned motor power at 230/240 V, 60 Hz, 3-phase
- 10 HP
- Drop-out voltage
- AC operated: 0.6 - 0.4 x UC, AC operated
- Power consumption, sealing, 60 Hz
- 2.1 W, Dual-frequency coil in a cold state and 1.0 x Us
- Resistance per pole
- 2.7 mΩ
- Ambient operating temperature (enclosed) - min
- 25°C
- Stripping length (control circuit cable)
- 10 mm
- 10.12 Electromagnetic compatibility
- Is the panel builder's responsibility. The specifications for the switchgear must be observed.
- Special purpose rating of refrigeration control (CSA only)
- 40 A, FLA 480 V 60 Hz 3phase; (CSA)
- Amperage Rating
- 200A
- 10.2.5 Lifting
- Does not apply, since the entire switchgear needs to be evaluated.
- Stripping length (main cable)
- 10 mm
- Ambient operating temperature (enclosed) - max
- 40°C
- Special purpose rating of resistance air heating
- 40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
- Rated control supply voltage (Us) at DC - min
- 0 V
- Short-circuit current rating (high fault at 600 V)
- 10/100 kA, Fuse, SCCR (UL/CSA)
- Frequency rating
- 50-60 Hz
- 10.8 Connections for external conductors
- Is the panel builder's responsibility.
- Number of main contacts (normally open contact)
- 4
- Rated breaking capacity at 220/230 V
- 180 A
- Screw size
- M5, Terminal screw, Main cables
- Rated operational current (Ie) at AC-4, 400 V
- 15 A
- Terminals
- Screw terminals
- Short-circuit protection rating (type 2 coordination) at 690 V
- 35 A gG/gL
- Assigned motor power at 575/600 V, 60 Hz, 3-phase
- 20 HP
- Protection
- Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
- Power consumption, sealing, 50 Hz
- 2.1 W, Dual-frequency coil in a cold state and 1.0 x Us
- Terminal capacity (stranded)
- 1 x 16 mm², Main cables
- HP rating - max
- 2, 5/ 7.5, 10, 15 20 hp (1/3PH @120, 240/ 208, 240, 480, 600 V)
- Rated breaking capacity at 500 V
- 180 A
- Rated operational power at AC-1, 415 V, 50 Hz
- 22 kW
- Rated operational power at AC-3, 415 V, 50 Hz
- 10 kW
- Climatic proofing
- Damp heat, cyclic, to IEC 60068-2-30
- Connection to SmartWire-DT
- No
- Static heat dissipation, non-current-dependent Pvs
- 2.1 W
- Rated control supply voltage (Us) at DC - max
- 0 V
- 10.9.3 Impulse withstand voltage
- Is the panel builder's responsibility.
- Utilization category
- AC-1: Non-inductive or slightly inductive loads, resistance furnaces
- Coil voltage
- 230-240 Vac, 50/60 Hz
- Rated operational current (Ie) at AC-3, 440 V
- 18 A
- 10.5 Protection against electric shock
- Does not apply, since the entire switchgear needs to be evaluated.
- Safe isolation
- 440 V AC, Between coil and contactss, According to EN 61140
- Used with
- DILM32-XHI( C), DILA-XHI(V)( C)
- Rated operational power at AC-1, 220/230 V, 50 Hz
- 12 kW
- 10.13 Mechanical function
- The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
- 10.9.4 Testing of enclosures made of insulating material
- Is the panel builder's responsibility.
- Heat dissipation per pole, current-dependent Pvid
- 2.2 W
- Switching capacity (auxiliary contacts, general use)
- 10 A, 600 V AC, (UL/CSA)
- Operating temperature - min
- -25°C
- Residual current
- 1 mA (with actuation of A1 - A2 by the electronics with "0" signal)
- Equipment heat dissipation, current-dependent Pvid
- 6.6 W
- Assigned motor power at 200/208 V, 60 Hz, 3-phase
- 7.5 HP
- Pick-up voltage
- 0.8 - 1.1 V AC x Uc
- Operation
- Non-reversing
- Terminal capacity (solid)
- 1 x (0.75 - 4) mm², Control circuit cables
- Number of auxiliary contacts (normally closed contacts)
- 0
- Rated operational power at AC-1, 240 V, 50 Hz
- 13 kW
- Power consumption
- 7.5 kW
- 10.2.3.2 Verification of resistance of insulating materials to normal heat
- Meets the product standard's requirements.
- Operating temperature - max
- 60°C
- 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
- Meets the product standard's requirements.
- Lifespan, mechanical
- 10,000,000 Operations (AC operated)
- Short-circuit protection rating (type 1 coordination) at 690 V
- 50 A gG/gL
- Rated making capacity up to 690 V (cos phi to IEC/EN 60947)
- 238 A
- Number of contacts
- 1 NO
- Rated operational current (Ie) at DC-1, 60 V
- 32 A
- Rated operational voltage (Ue) at AC - max
- 690 V
- Rated control supply voltage (Us) at AC, 60 Hz - min
- 240 V
- 10.7 Internal electrical circuits and connections
- Is the panel builder's responsibility.
- 10.10 Temperature rise
- The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
- Switching capacity (main contacts, general use)
- 40 A, Maximum motor rating (UL/CSA)
- Rated operational current (Ie) at AC-3, 500 V
- 18 A
- Assigned motor power at 230/240 V, 60 Hz, 1-phase
- 5 HP
- Screwdriver size
- 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
- Duty factor
- 100 %
- Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
- 18 A
- Conventional thermal current ith of main contacts (1-pole, open)
- 84 A
- Rated control supply voltage (Us) at AC, 60 Hz - max
- 240 V
- Rated operational power at AC-1, 690 V, 50 Hz
- 35 kW
- Switching capacity (auxiliary contacts, pilot duty)
- P300, DC operated (UL/CSA)
- Rated insulation voltage (Ui)
- 690 V