- Number of Main Contacts NO
- 3
- Number of Main Contacts NC
- 0
- Number of Auxiliary Contacts NO
- 0
- Number of Auxiliary Contacts NC
- 0
- Standards
- IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
- Rated Operational Voltage
- Main Circuit 1000 V
- Rated Frequency (f)
- Control Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith)
- acc. to IEC 60947-4-1, Open Contactors ˜ = 40°C 130 A
- Rated Operational Current AC-1 (Ie)
- (690 V) 40°C 130 A(690 V) 60°C 105 A(690 V) 70°C 90 A
- Rated Operational Current AC-3 (Ie)
- (415 V) 60°C 96 A(440 V) 60°C 96 A(500 V) 60°C 80 A(690 V) 60°C 57 A(1000 V) 60°C 30 A(380 / 400 V) 60°C 105 A(220 / 230 / 240 V) 60°C 105 A
- Rated Operational Current AC-3e (Ie)
- (415 V) 60°C 96 A(440 V) 60°C 96 A(500 V) 60°C 80 A(690 V) 60°C 57 A(380 / 400 V) 60°C 105 A(220 / 230 / 240 V) 60°C 105 A
- Rated Operational Power AC-3 (Pe)
- (415 V) 55 kW(440 V) 55 kW(500 V) 55 kW(690 V) 55 kW(1000 V) 40 kW(380 / 400 V) 45 kW(380 / 400 V) 55 kW(220 / 230 / 240 V) 25 kW(220 / 230 / 240 V) 30 kW
- Rated Operational Power AC-3e (Pe)
- (415 V) 55 kW(440 V) 55 kW(500 V) 55 kW(690 V) 55 kW(380 / 400 V) 45 kW(380 / 400 V) 55 kW(220 / 230 / 240 V) 25 kW(220 / 230 / 240 V) 30 kW
- Rated Short-time Withstand Current Low Voltage (Icw)
- at 40°C Ambient Temp, in Free Air, from a Cold State 10 s 780 Aat 40°C Ambient Temp, in Free Air, from a Cold State 15 min 140 Aat 40°C Ambient Temp, in Free Air, from a Cold State 1 min 300 Aat 40°C Ambient Temp, in Free Air, from a Cold State 1 s 1200 Aat 40°C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
- Maximum Breaking Capacity
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
- Maximum Electrical Switching Frequency
- (AC-1) 600 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 1200 cycles per hour
- Rated Operational Current DC-1 (Ie)
- (110 V) 2 Poles in Series, 40°C 130 A(110 V) 2 Poles in Series, 60°C 105 A(110 V) 2 Poles in Series, 70°C 90 A(110 V) 3 Poles in Series, 40°C 130 A(110 V) 3 Poles in Series, 60°C 105 A(110 V) 3 Poles in Series, 70°C 90 A(220 V) 3 Poles in Series, 40°C 125 A(220 V) 3 Poles in Series, 60°C 105 A(220 V) 3 Poles in Series, 70°C 90 A(72 V) 1-Pole, 40°C 130 A(72 V) 1-Pole, 60°C 105 A(72 V) 1-Pole, 70°C 90 A(72 V) 2 Poles in Series, 40°C 130 A(72 V) 2 Poles in Series, 60°C 105 A(72 V) 2 Poles in Series, 70°C 90 A(72 V) 3 Poles in Series, 40°C 130 A(72 V) 3 Poles in Series, 60°C 105 A(72 V) 3 Poles in Series, 70°C 90 A
- Rated Operational Current DC-3 (Ie)
- (110 V) 2 Poles in Series, 40°C 130 A(110 V) 2 Poles in Series, 60°C 105 A(110 V) 2 Poles in Series, 70°C 90 A(110 V) 3 Poles in Series, 40°C 130 A(110 V) 3 Poles in Series, 60°C 105 A(110 V) 3 Poles in Series, 70°C 90 A(220 V) 3 Poles in Series, 40°C 130 A(220 V) 3 Poles in Series, 60°C 105 A(220 V) 3 Poles in Series, 70°C 90 A(72 V) 1-Pole, 40°C 130 A(72 V) 1-Pole, 60°C 105 A(72 V) 1-Pole, 70°C 90 A(72 V) 2 Poles in Series, 40°C 130 A(72 V) 2 Poles in Series, 60°C 105 A(72 V) 2 Poles in Series, 70°C 90 A(72 V) 3 Poles in Series, 40°C 130 A(72 V) 3 Poles in Series, 60°C 105 A(72 V) 3 Poles in Series, 70°C 90 A
- Rated Operational Current DC-5 (Ie)
- (110 V) 2 Poles in Series, 40°C 130 A(110 V) 2 Poles in Series, 60°C 105 A(110 V) 2 Poles in Series, 70°C 90 A(110 V) 3 Poles in Series, 40°C 130 A(110 V) 3 Poles in Series, 60°C 105 A(110 V) 3 Poles in Series, 70°C 90 A(220 V) 3 Poles in Series, 40°C 130 A(220 V) 3 Poles in Series, 60°C 105 A(220 V) 3 Poles in Series, 70°C 90 A(72 V) 1-Pole, 40°C 130 A(72 V) 1-Pole, 60°C 105 A(72 V) 1-Pole, 70°C 90 A(72 V) 2 Poles in Series, 40°C 130 A(72 V) 2 Poles in Series, 60°C 105 A(72 V) 2 Poles in Series, 70°C 90 A(72 V) 3 Poles in Series, 40°C 130 A(72 V) 3 Poles in Series, 60°C 105 A(72 V) 3 Poles in Series, 70°C 90 A
- Rated Insulation Voltage (Ui)
- acc. to IEC 60947-4-1 1000 Vacc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp)
- 8 kV
- Maximum Mechanical Switching Frequency
- 3600 cycles per hour
- Rated Control Circuit Voltage (Uc)
- 50 Hz 24 ... 60 V60 Hz 24 ... 60 VDC Operation -
- Operate Time
- Between Coil De-energization and NC Contact Closing 19 ... 105 msBetween Coil De-energization and NO Contact Opening 17 ... 100 msBetween Coil Energization and NC Contact Opening 38 ... 95 msBetween Coil Energization and NO Contact Closing 42 ... 100 ms
- Mounting on DIN Rail
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
- Mounting by Screws (not supplied)
- 2 x M4 or 2 x M6 screws placed diagonally
- Connecting Capacity Main Circuit
- Flexible with Ferrule 1/2x 6 ... 50 mm²Flexible with Insulated Ferrule 1/2x 6 ... 50 mm²Rigid Stranded 1x 6 ... 70 mm²Rigid Stranded 2x 6 ... 50 mm²
- Connecting Capacity Control Circuit
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
- Wire Stripping Length
- Control Circuit 10 mmMain Circuit 17 mm
- Degree of Protection
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
- Terminal Type
- Screw Terminals
- Ambient Air Temperature
- Close to Contactor Fitted with Thermal O/L Relay -40 ... 70°CClose to Contactor without Thermal O/L Relay -40 ... 70°CClose to Contactor for Storage -60 ... +80°C
- Climatic Withstand
- Category B according to IEC 60947-1 Annex Q
- Maximum Operating Altitude Permissible
- Without Derating 3000 m
- Resistance to Vibrations acc. to IEC 60068-2-6
- 5 ... 300 Hz 3 g closed position / 3 g open position
- Resistance to Shock acc. to IEC 60068-2-27
- Closed, Shock Direction: A 25 gClosed, Shock Direction: B1 25 gClosed, Shock Direction: B2 15 gClosed, Shock Direction: C1 25 gClosed, Shock Direction: C2 25 gOpen, Shock Direction: B1 5 g
- RoHS Status
- Following EU Directive 2011/65/EU