Dropship Automation

ABB AF145-30-11-70

SKU: DA-986949
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number AF145-30-11-70 UPC 73205002201910 UNSPSC 39121529 ETIM Group Code : EG000017 Group Description : Low-voltage Industrial Components Class Description : Power contactor, AC switching Class Code : EC000066 Version : 7 Dimensions Product Net Width 111.5 mm Product Net Depth / Length 160 mm Product Net Height 196 mm Product Net Weight 3.4 kg Technical Number of...

Additional Information

Part Number
AF145-30-11-70
UPC
73205002201910
UNSPSC
39121529
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Power contactor, AC switching
Class Code : EC000066
Version : 7

Dimensions

Product Net Width
111.5 mm
Product Net Depth / Length
160 mm
Product Net Height
196 mm
Product Net Weight
3.4 kg

Technical

Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors ? = 40°C 250 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40°C 180 A(1000 V) 55°C 180 A(1000 V) 70°C 180 A(690 V) 40°C 250 A(690 V) 55°C 230 A(690 V) 70°C 180 A
Rated Operational Current AC-3 (Ie)
(415 V) 55°C 145 A(440 V) 55°C 145 A(500 V) 55°C 145 A(690 V) 55°C 120 A(1000 V) 55°C 80 A(380 / 400 V) 55°C 145 A(220 / 230 / 240 V) 55°C 145
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW(440 V) 75 kW(500 V) 90 kW(690 V) 110 kW(1000 V) 110 kW(380 / 400 V) 75 kW(220 / 230 / 240 V) 45 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 315 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40°C Ambient Temp, in Free Air, from a Cold State 10 s 1200 Aat 40°C Ambient Temp, in Free Air, from a Cold State 15 min 280 Aat 40°C Ambient Temp, in Free Air, from a Cold State 1 min 600 Aat 40°C Ambient Temp, in Free Air, from a Cold State 1 s 1800 Aat 40°C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1500 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1200 A
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40°C 250 A(220 V) 3 Poles in Series, 40°C 250 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40°C 250 A(220 V) 3 Poles in Series, 40°C 250 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40°C 250 A(220 V) 3 Poles in Series, 40°C 250 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ? ? 70°C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 2 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 430 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 430 V·APull-in at Max. Rated Control Circuit Voltage DC 500 W
Operate Time
Between Coil De-energization and NC Contact Closing 40 .... 50 msBetween Coil De-energization and NO Contact Opening 43 ... 53 msBetween Coil Energization and NC Contact Opening 45 ... 85 msBetween Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit
Bar 24 mm²Rigid Al-Cable 1 x 25 ... 150 mm²Rigid Cu-Cable 1 x 6 ... 185 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type
Main Circuit: Bars

Classifications

Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
EClass
V11.0 : 27371003
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3709245
E-Number (Norway)
4115267
E-Number (Sweden)
3228286

Environmental

Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50°CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70°CClose to Contactor for Storage -40 ... 70°C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 gShock Direction: B1 5 gShock Direction: B2 5 gShock Direction: C1 5 gShock Direction: C2 5 g
RoHS Status
Following EU Directive 2011/65/EU

Technical UL/CSA

NEMA Size
4
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 230 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 40 hp(208 V AC) Three Phase 40 hp(220 ... 240 V AC) Three Phase 50 hp(440 ... 480 V AC) Three Phase 100 hp(550 ... 600 V AC) Three Phase 125 hp

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL447002R1311

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products