Additional Information Part Number A110-30-00-81 UNSPSC 39121529 ETIM Group Code : EG000017 Group Description : Low-voltage Industrial Components Class Description : Power contactor, AC switching Class Code : EC000066 Version : 7 Dimensions Product Net Width 90 mm Product Net Depth / Length 123.5 mm Product Net Height 148 mm Product Net Weight 1.8 kg Technical Number of Main Contacts...

Additional Information

Part Number
A110-30-00-81
UNSPSC
39121529
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Power contactor, AC switching
Class Code : EC000066
Version : 7

Dimensions

Product Net Width
90 mm
Product Net Depth / Length
123.5 mm
Product Net Height
148 mm
Product Net Weight
1.8 kg

Technical

Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors ? = 40¡C 160 A
Rated Operational Current AC-1 (Ie)
(690 V) 40¡C 160 A(690 V) 55¡C 145 A(690 V) 70¡C 130 A
Rated Operational Current AC-3 (Ie)
(415 V) 55¡C 110 A(440 V) 55¡C 100 A(500 V) 55¡C 100 A(690 V) 55¡C 82 A(1000 V) 55¡C 30 A(380 / 400 V) 55¡C 110 A(220 / 230 / 240 V) 55¡C 110
Rated Operational Power AC-3 (Pe)
(415 V) 59 kW(440 V) 59 kW(500 V) 59 kW(690 V) 75 kW(1000 V) 40 kW(380 / 400 V) 55 kW(220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 200 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40¡C Ambient Temp, in Free Air, from a Cold State 10 s 800 Aat 40¡C Ambient Temp, in Free Air, from a Cold State 15 min 175 Aat 40¡C Ambient Temp, in Free Air, from a Cold State 1 min 350 Aat 40¡C Ambient Temp, in Free Air, from a Cold State 1 s 1320 Aat 40¡C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40¡C 160 A(220 V) 3 Poles in Series, 40¡C 160 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40¡C 160 A(220 V) 3 Poles in Series, 40¡C 160 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40¡C 160 A(220 V) 3 Poles in Series, 40¡C 160 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Mechanical Durability
10 million
Maximum Mechanical Switching Frequency
3600 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ? ² 70¡C)
Rated Control Circuit Voltage (Uc)
50 Hz 24 V60 Hz 24 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 22 VáAHolding at Max. Rated Control Circuit Voltage 60 Hz 26 VáAPull-in at Max. Rated Control Circuit Voltage 50 Hz 350 VáAPull-in at Max. Rated Control Circuit Voltage 60 Hz 450 VáA
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 15 msBetween Coil Energization and NO Contact Closing 10 ... 25 ms
Connecting Capacity Main Circuit
Bar 30 mm?Flexible with Cable End 1 x 10 ... 70 mm?Rigid 2 x 6 ... 65 mm?
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm?Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm?Flexible 1x0.75 ... 2.5 mm?Solid 2 x 1 ... 4 mm?Stranded 1 x 1 .... 4 mm?
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles
M8 hexagon socket screw with single connector
Terminal Type
Cable Clamp

Classifications

Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
EClass
V11.0 : 27371003
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Norway)
4115021
E-Number (Sweden)
3227841

Environmental

Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50¡CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70¡CClose to Contactor for Storage -60 ... +80¡C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
RoHS Status
Following EU Directive 2011/65/EU

Technical UL/CSA

Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 140 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 30 hp(208 V AC) Three Phase 30 hp(220 ... 240 V AC) Three Phase 40 hp(440 ... 480 V AC) Three Phase 75 hp(550 ... 600 V AC) Three Phase 100 hp

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL427001R1100

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products