- Part Number
- 1SFL547102R1211
- UNSPSC
- 39121529
- Product Net Width
- 184.4 mm
- Product Net Depth / Length
- 180 mm
- Product Net Height
- 225 mm
- Product Net Weight
- 5.7 kg
- Number of Main Contacts NO
- 4
- Number of Main Contacts NC
- 0
- Number of Auxiliary Contacts NO
- 1
- Number of Auxiliary Contacts NC
- 1
- Rated Operational Voltage
- Main Circuit 1000 V
- Rated Frequency (f)
- Main Circuit 60 Hz
- Conventional Free-air Thermal Current (Ith)
- acc. to IEC 60947-4-1, Open Contactors ˜ = 40°C 400 A
- Rated Operational Current AC-1 (Ie)
- (1000 V) 40°C 350 A(1000 V) 60°C 300 A(1000 V) 70°C 240 A(690 V) 40°C 400 A(690 V) 60°C 350 A(690 V) 70°C 290 A
- Rated Operational Current AC-3 (Ie)
- (415 V) 55°C 265 A(440 V) 55°C 265 A(500 V) 55°C 250 A(690 V) 55°C 250 A(380 / 400 V) 55°C 265 A(220 / 230 / 240 V) 55°C 265
- Rated Operational Power AC-3 (Pe)
- (415 V) 132 kW(440 V) 160 kW(380 / 400 V) 132 kW(220 / 230 / 240 V) 75 kW
- Rated Breaking Capacity AC-3
- 8 x Ie AC-3
- Rated Making Capacity AC-3
- 10 x Ie AC-3
- Short-Circuit Protective Devices
- gG Type Fuses 630 A
- Rated Short-time Withstand Current Low Voltage (Icw)
- at 40°C Ambient Temp, in Free Air, from a Cold State 10 s 2120 Aat 40°C Ambient Temp, in Free Air, from a Cold State 15 min 400 Aat 40°C Ambient Temp, in Free Air, from a Cold State 1 min 865 Aat 40°C Ambient Temp, in Free Air, from a Cold State 1 s 2650 Aat 40°C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
- Maximum Breaking Capacity
- cos phi=0.45 (cos phi=0.35 for Ie >; 100 A) at 440 V 3800 A
- Maximum Electrical Switching Frequency
- (AC-1) 300 cycles per hour
- Rated Insulation Voltage (Ui)
- acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp)
- Main Circuit 8 kV
- Mechanical Durability
- 5 million
- Maximum Mechanical Switching Frequency
- 300 cycles per hour
- Coil Operating Limits
- (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ¸ ‰¤ 70°C)
- Rated Control Circuit Voltage (Uc)
- 50 Hz 48 ... 130 V60 Hz 48 ... 130 VDC Operation 48 ... 130 V
- Coil Consumption
- Holding at Max. Rated Control Circuit Voltage 50 Hz 17 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 17 V·AHolding at Max. Rated Control Circuit Voltage DC 2.5 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 180 V·APull-in at Max. Rated Control Circuit Voltage DC 150 W
- Operate Time
- Between Coil De-energization and NO Contact Opening 45 ... 80 msBetween Coil Energization and NO Contact Closing 30 ... 60 ms
- Connecting Capacity Main Circuit
- Flexible 1 x 16 ... 240 mm²Rigid Al-Cable 1 x 185 ... 240 mm²Rigid Cu-Cable 2 x 70 ... 185 mm²
- Connecting Capacity Auxiliary Circuit
- Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 1 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²
- Degree of Protection
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
- Terminal Type
- Main Circuit: Bars
- Environmental Product Declaration - EPD
- 1SFC100104D0201
- Object Classification Code
- Q
- ETIM 4
- EC000066 - Magnet contactor, AC-switching
- ETIM 5
- EC000066 - Magnet contactor, AC-switching
- EClass
- V11.0 : 27371003
- IDEA Granular Category Code (IGCC)
- 4758 >;>; Iec Contactors
- E-Number (Finland)
- 3707223
- E-Number (Norway)
- 3210339
- E-Number (Sweden)
- 3210339
- Ambient Air Temperature
- Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50°CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70°CClose to Contactor for Storage -40 ... 70°C
- Maximum Operating Altitude Permissible
- Without Derating 3000 m
- RoHS Status
- Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- ABB EcoSolutions
- Yes
- Circular Design Principles Recyclability Rate
- Design for Closing Resource Loops - Standard EN45555 - 76.3 %
- End of Life Instructions
- 1SFC100112M0001
- Group Waste to Landfill Target
- Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
- Improved Resource Efficiency for Customers
- Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
- Sustainable Material Content
- Recycled Metal - 33 %
- NEMA Size
- 5
- Horsepower Rating NEMA
- (200 V AC) Three Phase 75 Hp(230 V AC) Three Phase 100 Hp(460 V AC) Three Phase 200 Hp(575 V AC) Three Phase 200 Hp
- Maximum Operating Voltage UL/CSA
- Main Circuit 1000 V
- General Use Rating UL/CSA
- (600 V AC) 300 A
- Horsepower Rating UL/CSA
- (200 ... 208 V AC) Three Phase 40 Hp(200 V AC) Three Phase 75 hp(208 V AC) Three Phase 75 hp(220 ... 240 V AC) Three Phase 40 Hp(220 ... 240 V AC) Three Phase 100 hp(440 ... 480 V AC) Three Phase 100 Hp(440 ... 480 V AC) Three Phase 200 hp(550 ... 600 V AC) Three Phase 125 Hp(550 ... 600 V AC) Three Phase 250 hp
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85364900