Additional Information
- Part Number
- 1SDA071221R1
- UNSPSC
- 39121615
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Power circuit-breaker for trafo/generator/installation protection
- Class Code : EC000228
- Version : 7
Additional Information
- Current Type
- AC
- Electrical Durability
- Ue =< 440 V 5000 cycleUe = 500 ... 690 V 4000 cycle20 cycles per hour
- Mechanical Durability
- 15000 cycle60 cycles per hour
- Number of Poles
- 3
- Power Loss
- 465 W
- Product Main Type
- SACE Emax 2
- Product Name
- Air Circuit Breaker
- Product Type
- Air Circuit Breaker
- Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)
- 100 %
- Rated Current (In)
- 4000 A
- Rated Voltage (Ur)
- 690 V
- Rated Impulse Withstand Voltage (Uimp)
- acc. to IEC 60947-2 12 kV
- Rated Insulation Voltage (Ui)
- AC 1000 V
- Rated Operational Voltage
- 690 V AC
- Rated Service Short-Circuit Breaking Capacity (Ics)
- (220 V AC) 150 kA(230 V AC) 150 kA(380 V AC) 150 kA(400 V AC) 150 kA(415 V AC) 150 kA(440 V AC) 150 kA(500 V AC) 100 kA(660 V AC) 100 kA(690 V AC) 100 kA
- Rated Short-time Withstand Current Low Voltage (Icw)
- for 1 s 100 kAfor 3 s 75 kA
- Rated Ultimate Short-Circuit Breaking Capacity (Icu)
- (400 V AC) 150 kA(415 V AC) 150 kA(440 V AC) 150 kA(500 V AC) 100 kA(525 V AC) 100 kA(690 V AC) 100 kA
- Rated Uninterrupted Current (Iu)
- 4000 A
- Recommended Screw Driver
- Main Circuit M12
- Release
- Ekip Dip LI
- Release Type
- EL
- Short-Circuit Performance Level
- V
- Standards
- IEC
- Sub-type
- E4.2
- Terminal Connection Type
- Rear flat Horizontal
- Terminal Type
- Bolt
- Tightening Torque
- 70 N·m
- Version
- F
- CAD Dimensional Drawing
- 1SDH001252R0171
Dimensions
- Product Net Width
- 384 mm
- Product Net Height
- 371 mm
- Product Net Depth / Length
- 270 mm
- Product Net Weight
- 56 kg
ABB EcoSolutions
- ABB EcoSolutions
- Yes
Eco Transparency
- Environmental Product Declaration - EPD
- 9AKK108468A1904 9AKK108468A1910
Classifications
- ETIM 9
- EC000228 - Power circuit-breaker for trafo/generator/installation protection
- IDEA Granular Category Code (IGCC)
- 4926 >> Air circuit breakers
- Object Classification Code
- Q
- WEEE Category
- 5. Small Equipment (No External Dimension More Than 50 cm)
- EClass
- V11.1 : 27370409
Environmental
- Environmental Information
- 9AKK10103A1038 9AKK108467A6707
- REACH Declaration
- 9AKK108466A1425
- RoHS Information
- 9AKK108466A1424
- RoHS Status
- Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP
- 3bc060e7-331b-4845-9578-43281338fad7 Italy (IT)
- Simplified SCIP
- 9668a536-c52e-4a7d-9f8e-db8919e7cbfa Poland (PL)52319acc-f753-4102-aef8-036a88d129e4 Poland (PL)fe7c270c-478c-4126-9bd8-60e958bfdef0 Czech Republic (CZ)34a54260-5b83-4728-b875-6555eb9b63d4 Sweden (SE)03b8af72-3cec-420d-a13f-36c25da53f21 Portugal (PT)7be4ba70-b98d-4c75-9027-ff95aaa462cc Belgium (BE)b1b81fbb-e154-4b29-899c-ba99f31e467d Spain (ES)8091c1fd-2aa2-4e25-907c-9c27ec34c2dc Hungary (HU)dfe95a3c-7fab-49f4-9570-e47857a771a1 Norway (NO)f0969fc5-4e9f-4cee-a445-9c3f7209edb2 Poland (PL)aec79f5e-aeb0-4633-a820-588845b43b1b Bulgaria (BG)e1a8c640-14bf-4b10-ac51-3a84a588518a Germany (DE)b9c2e1a2-4604-45bc-aab4-1f6798d9ae95 Germany (DE)8033ee67-cee6-431c-8d6d-51675d222a97 Croatia (HR)cc3dc7df-b4c6-4ea1-9513-54d9055cdd1c Denmark (DK)8c3a1773-d9c2-4044-a112-6381ab1f2630 Germany (DE)0fbca3c1-dfb4-4d36-b5c8-9bf327f7df7e Germany (DE)56b7f8d7-b486-4565-aee3-bae6dd71c783 Sweden (SE)26f6b73d-11b2-400e-a474-af64f3a0432e Belgium (BE)1e47c9f1-e8ce-44f1-a5b8-24632d9f4c5f Estonia (EE)3271c045-d8ba-458f-bc1a-52a299c34de5 Netherlands (NL)6cf4a534-a345-428f-ac45-e8fe91a8a032 Finland (FI)dc3aa9d8-547c-426e-bcf4-59f8b49a0110 Greece (GR)badf12d3-3013-44f1-86a0-92dadbfbe89a France (FR)ad904118-be52-4035-8d02-a95dab4d8e64 France (FR)20786fcd-b845-44d3-b834-bc41c7188db3 Hungary (HU)
Circular Value
- Circular Design Principles Recyclability Rate
- Design for Closing Resource Loops - Standard EN45555 - 79.3 %
- Conflict Minerals Reporting Template (CMRT)
- 9AKK108467A5658
- End of Life Instructions
- 9AKK108468A2363
- Group Waste to Landfill Target
- UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA
- 9AKK108467A8326
Ordering
- Order Code US and Canada
- Z4VWERBA000A000000XX
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85362090