{"product_id":"weidmuller-8965360000","title":"WEIDMULLER 8965360000","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e8965360000\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eProbability Of Failure\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMTBF\u003c\/dt\u003e\n\u003cdd\u003e215 Years\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSIL PAPER\u003c\/dt\u003e\n\u003cdd\u003eSIL certificate\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eDigital Output\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eType\u003c\/dt\u003e\n\u003cdd\u003eNPN-Transitor, Switching frequency 5 kHz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal switching voltage\u003c\/dt\u003e\n\u003cdd\u003e30 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eContinuous current\u003c\/dt\u003e\n\u003cdd\u003e80 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFunction\u003c\/dt\u003e\n\u003cdd\u003eOutput = input, direct or inverse (configurable)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eApprovals\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eROHS\u003c\/dt\u003e\n\u003cdd\u003eConform\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUL File Number Search\u003c\/dt\u003e\n\u003cdd\u003eE337701\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eDimensions And Weights\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e22.5 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth (inches)\u003c\/dt\u003e\n\u003cdd\u003e0.886 inch\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e119.2 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight (inches)\u003c\/dt\u003e\n\u003cdd\u003e4.693 inch\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e113.6 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth (inches)\u003c\/dt\u003e\n\u003cdd\u003e4.472 inch\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNet weight\u003c\/dt\u003e\n\u003cdd\u003e170 g\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSafety-Related Specifications Low Demand Mode\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAverage Probability of Failure on Demand (PFD\u003c\/dt\u003e\n\u003cdd\u003e1.58 x 10-4 (Tproof = 1 year), 3.17 x 10-4 (Tproof = 2 years), 7.92 x 10-4 (Tproof = 5 years)\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eConnection Data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eType of connection\u003c\/dt\u003e\n\u003cdd\u003eScrew connection\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTightening torque, min.\u003c\/dt\u003e\n\u003cdd\u003e0.4 Nm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTightening torque, max.\u003c\/dt\u003e\n\u003cdd\u003e0.6 Nm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eClamping range, rated connection\u003c\/dt\u003e\n\u003cdd\u003e2.5 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eClamping range, min.\u003c\/dt\u003e\n\u003cdd\u003e0.25 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eClamping range, max.\u003c\/dt\u003e\n\u003cdd\u003e2.5 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWire connection cross section AWG, min.\u003c\/dt\u003e\n\u003cdd\u003eAWG 26\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWire connection cross section AWG, max.\u003c\/dt\u003e\n\u003cdd\u003eAWG 12\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eRated Data Ul\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUL certificate\u003c\/dt\u003e\n\u003cdd\u003eE337701.pdf\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSafety-Related Basic Specifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDemand mode\u003c\/dt\u003e\n\u003cdd\u003eHigh\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDemand rate\u003c\/dt\u003e\n\u003cdd\u003e1,000 s\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDescription of the \"safe state\"\u003c\/dt\u003e\n\u003cdd\u003eHigh impedance\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice type\u003c\/dt\u003e\n\u003cdd\u003eB\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDiagnostic test interval\u003c\/dt\u003e\n\u003cdd\u003e10 s\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHardware fault tolerance (HFT)\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMean Time To Repair (MTTR)\u003c\/dt\u003e\n\u003cdd\u003e8 h\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSafe Failure Fraction (SFF)\u003c\/dt\u003e\n\u003cdd\u003e92 %\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eT\u003c\/dt\u003e\n\u003cdd\u003e5 Years\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTotal failure rate for dangerous detected failures (»\u003c\/dt\u003e\n\u003cdd\u003e135 FIT\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTotal failure rate for dangerous undetected failures (»\u003c\/dt\u003e\n\u003cdd\u003e36 FIT\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTotal failure rate for safe detected failures (»\u003c\/dt\u003e\n\u003cdd\u003e0 FIT\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTotal failure rate for safe undetected failures (»\u003c\/dt\u003e\n\u003cdd\u003e275 FIT\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSafety category\u003c\/dt\u003e\n\u003cdd\u003eSIL 2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProbability of outage PFH\u003c\/dt\u003e\n\u003cdd\u003e3.62 x 10-8 h-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eTender Specification Sheets\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLong specification\u003c\/dt\u003e\n\u003cdd\u003eEx isolating switch amplifiers for Namur sensors,1-channel isolating switch amplifiers in 22.5 mm width with an external power supply,to transmit and isolate Namur sensor signals from Ex zones 0,1, 2 into the safe zone. On the output side there is an NPN switching transistor and a common alarm contact (relay\/\"a\" contact) for status or error messages.The component can be configured using standard FDT\/DTM software.Add-on housing for TS35 DIN rail installationDimensions: L\/W\/H 119.2\/ 22.5\/ 113.6screw connection\/ nominal cross-section 2.5 mm2Protection degree: IP20   Input                       NAMUR sensor according to EN 60947                                     8 VDC \/ 8 mA sensor power supply                                     0 to 5 kHz input frequency                                     wire-break detectionOutput                                          NPN transistor                                     30 VDC @ 80 mA                                      5 kHz switching frequency                                     \u0026lt; 2, 5 VDC SpannungsfallAlarm output relay 1 NO contact                                      250 VAC \/ 30 VDC @ 2A safe zone                                     32 VAC @ 0.5 A\/ 32 VDC @ 1 A zone 2Auxiliary power                                    19...31.2 VDCPower loss approx. 1.8 WAmbienttemperature range -20°C to +60°CSecure isolation                  EN 61010, 3-way isolation up to 2.6 kV AC\/DC of all circuits against each otherWorking voltage                   300 V AC\/DC at overvoltage category II and pollution degree 2Approvals cULus, ATEX IECEX, FM ATEX marking II 3 G ExnA nC IIC T4 ATEX characteristic data U0 = 10, 6 V DC                                      I0  = 12 mA DC                                      P0 = 32 WType                                                             ACT20X-HDI-2SDO-2SDO-S\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort specification\u003c\/dt\u003e\n\u003cdd\u003eEx isolating switch amplifiers for Namur sensors,1-channel isolating switch amplifiers in 22.5 mm width with an external power supply,to transmit and isolate Namur sensor signals from Ex zones 0,1, 2 into the safe zone. On the output side there is an NPN switching transistor and a common alarm contact (relay\/\"a\" contact) for status or error messages.The component can be configured using standard FDT\/DTM software.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eAlarm Output\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAlarm function\u003c\/dt\u003e\n\u003cdd\u003eLine interruption at the input, Short circuit at input, No supply voltage, Device error\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eType\u003c\/dt\u003e\n\u003cdd\u003eRelay, 1 NC (voltage-free)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal switching voltage\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 125 V AC \/ 110 V DC (safe area)‰¤ 32 V AC \/ 32 V DC (zone 2)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eContinuous current\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 0.5 A AC \/ 0.3 A DC (safe zone), ‰¤ 0,5 A AC \/ 1 A DC (zone 2)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower rating\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 62.5 VA \/ 32 W (safe area)‰¤ 16 VA \/ 32 W (Zone 2)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eClassifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eETIM 6.0\u003c\/dt\u003e\n\u003cdd\u003eEC002653\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eETIM 7.0\u003c\/dt\u003e\n\u003cdd\u003eEC002653\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEClass 9.0\u003c\/dt\u003e\n\u003cdd\u003e27-21-01-20\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEClass 9.1\u003c\/dt\u003e\n\u003cdd\u003e27-21-01-20\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEClass 10.0\u003c\/dt\u003e\n\u003cdd\u003e27-21-01-20\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUNSPSC\u003c\/dt\u003e\n\u003cdd\u003e30-21-18-01\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eOutput\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInfluence of load resistance\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 0.01% of span \/ 100 ©\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eProduct Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct information\u003c\/dt\u003e\n\u003cdd\u003eWeidmüller provides an extended guarantee period of 36 months for this device.\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironmental Product Compliance\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eREACH SVHC\u003c\/dt\u003e\n\u003cdd\u003eLead 7439-92-1\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eData For Ex Applications (Atex)\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage U\u003c\/dt\u003e\n\u003cdd\u003e10.6 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent I\u003c\/dt\u003e\n\u003cdd\u003e12 mA DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower P\u003c\/dt\u003e\n\u003cdd\u003e32 mW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMarking\u003c\/dt\u003e\n\u003cdd\u003eII (1) G [Ex ia Ga] IIC\/IIB\/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInstallation location\u003c\/dt\u003e\n\u003cdd\u003eDevice installed in safe area, zone 2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eInsulation Coordination\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEMC standards\u003c\/dt\u003e\n\u003cdd\u003eDIN EN 61326, NE 21\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInsulation voltage\u003c\/dt\u003e\n\u003cdd\u003e2.6 kV (input \/ output)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated voltage\u003c\/dt\u003e\n\u003cdd\u003e300 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eInput Ex\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInput frequency\u003c\/dt\u003e\n\u003cdd\u003e0...5 kHz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInput resistance\u003c\/dt\u003e\n\u003cdd\u003e1 k©\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOutput signal in case of wire break\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt; 0.1 mA, \u0026gt; 6.5 mA (in case of wire break)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePulse duration\u003c\/dt\u003e\n\u003cdd\u003e\u0026gt; 0.1 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResistance\u003c\/dt\u003e\n\u003cdd\u003eSeries resistor 750©, Parallel resistor 15k©\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSensor\u003c\/dt\u003e\n\u003cdd\u003eNAMUR sensor, according to EN60947, switch with or without RS, RP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSensor supply\u003c\/dt\u003e\n\u003cdd\u003e8 V DC \/ 8 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTrigger level high\u003c\/dt\u003e\n\u003cdd\u003e\u0026gt; 2.1 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTrigger level low\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt; 1.2 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eType\u003c\/dt\u003e\n\u003cdd\u003eintrinsically safe circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eTemperatures\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHumidity\u003c\/dt\u003e\n\u003cdd\u003e0...95 % (no condensation)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating temperature, max.\u003c\/dt\u003e\n\u003cdd\u003e60 °C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating temperature, min.\u003c\/dt\u003e\n\u003cdd\u003e-20 °C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStorage temperature, max.\u003c\/dt\u003e\n\u003cdd\u003e85 °C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStorage temperature, min.\u003c\/dt\u003e\n\u003cdd\u003e-20 °C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating temperature\u003c\/dt\u003e\n\u003cdd\u003e-20°C...60°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStorage temperature\u003c\/dt\u003e\n\u003cdd\u003e-20°C...85°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eRatings Iecex\/Atex\/Cul\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eATEX certificate\u003c\/dt\u003e\n\u003cdd\u003e09ATEX0168X.pdf\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIEC Ex certificate\u003c\/dt\u003e\n\u003cdd\u003eIECEx certification\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCertificate No. (ATEX)\u003c\/dt\u003e\n\u003cdd\u003eKEMA09ATEX0168X\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCertificate No. (IECEX)\u003c\/dt\u003e\n\u003cdd\u003eIECEXKEM09.0072X\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCertificate no. (cULus)\u003c\/dt\u003e\n\u003cdd\u003eE337701\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eGeneral Specifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConfiguration\u003c\/dt\u003e\n\u003cdd\u003eWith FDT\/DTM software\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage supply\u003c\/dt\u003e\n\u003cdd\u003e19.2€¦31.2 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eType of connection\u003c\/dt\u003e\n\u003cdd\u003eScrew connection\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNAMUR supply\u003c\/dt\u003e\n\u003cdd\u003e8 V DC \/ 8 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 1.1 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtection degree\u003c\/dt\u003e\n\u003cdd\u003eIP20\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHumidity\u003c\/dt\u003e\n\u003cdd\u003e0...95 % (no condensation)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49019657322781,"sku":"DA-203455","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/weidmuller-8965360000-dropship-automation.webp?v=1752695223","url":"https:\/\/dropshipautomation.com\/products\/weidmuller-8965360000","provider":"Dropship Automation","version":"1.0","type":"link"}