{"product_id":"weidmuller-1435590000","title":"WEIDMULLER 1435590000","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e1435590000\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eGeneral Data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAccuracy\u003c\/dt\u003e\n\u003cdd\u003eabsolute accuracy: \u0026lt; ±0.05 % of the measurement range, RTD (PT100) Basic accuracy: \u0026lt; ±0.1°C of the measurement range, TC (J,K) Basic accuracy: \u0026lt; ±0.5°C of the measurement range\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCold-junction compensation error\u003c\/dt\u003e\n\u003cdd\u003e±(2.0°C + 0.4°C x ”t) ”t = inside temperature “ ambient temperature\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConfiguration\u003c\/dt\u003e\n\u003cdd\u003eDIP switch\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eGalvanic isolation\u003c\/dt\u003e\n\u003cdd\u003e2-way isolator\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption, max.\u003c\/dt\u003e\n\u003cdd\u003e0.8 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption, typ.\u003c\/dt\u003e\n\u003cdd\u003e0.48 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRail\u003c\/dt\u003e\n\u003cdd\u003eTS 35\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStep response time\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 30 ms, \u0026lt; 300 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTemperature coefficient\u003c\/dt\u003e\n\u003cdd\u003eRTD (PT100) ‰¤0.01 % of the measurement range�„°C or 0.02°C �„°C, TC (J,K) 0.1°C �„°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage supply\u003c\/dt\u003e\n\u003cdd\u003eOutput loop powered, 6¦35 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eProbability Of Failure\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMTBF\u003c\/dt\u003e\n\u003cdd\u003e207 Years\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eApprovals\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eApprovals\u003c\/dt\u003e\n\u003cdd\u003eCULUS, DETNORVER, DNV GL, EAC, FMEX, IECEXKEM, KEMAATEX\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eROHS\u003c\/dt\u003e\n\u003cdd\u003eConform\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUL File Number Search\u003c\/dt\u003e\n\u003cdd\u003eE337701\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eDimensions And Weights\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e6.1 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth (inches)\u003c\/dt\u003e\n\u003cdd\u003e0.24 inch\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e112.5 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight (inches)\u003c\/dt\u003e\n\u003cdd\u003e4.429 inch\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e114.3 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth (inches)\u003c\/dt\u003e\n\u003cdd\u003e4.5 inch\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNet weight\u003c\/dt\u003e\n\u003cdd\u003e80 g\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eConnection Data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eType of connection\u003c\/dt\u003e\n\u003cdd\u003eScrew connection\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTightening torque, min.\u003c\/dt\u003e\n\u003cdd\u003e0.4 Nm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTightening torque, max.\u003c\/dt\u003e\n\u003cdd\u003e0.6 Nm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eClamping range, rated connection\u003c\/dt\u003e\n\u003cdd\u003e2.5 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eClamping range, min.\u003c\/dt\u003e\n\u003cdd\u003e0.5 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eClamping range, max.\u003c\/dt\u003e\n\u003cdd\u003e2.5 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWire connection cross section AWG, min.\u003c\/dt\u003e\n\u003cdd\u003eAWG 30\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWire connection cross section AWG, max.\u003c\/dt\u003e\n\u003cdd\u003eAWG 14\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eRated Data Ul\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUL certificate\u003c\/dt\u003e\n\u003cdd\u003eE337701.pdf\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eInput\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of inputs\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSensor\u003c\/dt\u003e\n\u003cdd\u003ePT100 \/ 2-\/3-\/4-wire, Thermocouple acc. to IEC 584, type: J, Thermocouple acc. to IEC 584, type: K\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInfluence of the sensor cable resistance\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt; 0.002 ©�„©\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInput measurement range\u003c\/dt\u003e\n\u003cdd\u003ePT100 -200¦+850°C, Thermocouple type J -100¦+1200°C, Thermocouple type K -200¦+1370°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLine resistance in measuring circuit\u003c\/dt\u003e\n\u003cdd\u003e50 ©@ RTD (Pt100), 10 k© @ TC (J, K)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTemperature input range\u003c\/dt\u003e\n\u003cdd\u003eConfigurable, min. measurement range 10°C (RTD), min. measurement range 50°C (TC)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eClassifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eETIM 6.0\u003c\/dt\u003e\n\u003cdd\u003eEC002919\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eETIM 7.0\u003c\/dt\u003e\n\u003cdd\u003eEC002919\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEClass 9.0\u003c\/dt\u003e\n\u003cdd\u003e27-21-01-29\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEClass 9.1\u003c\/dt\u003e\n\u003cdd\u003e27-21-01-29\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEClass 10.0\u003c\/dt\u003e\n\u003cdd\u003e27-21-01-29\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eOutput\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of outputs\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOutput current\u003c\/dt\u003e\n\u003cdd\u003econfigurable, 4...20 mA, 20¦4 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWire break detection\u003c\/dt\u003e\n\u003cdd\u003e3.5 mA �„ 23 mA �„ none\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCold junction compensation\u003c\/dt\u003e\n\u003cdd\u003econfigurable internal or external cold-junction compensation (thermocouple)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply voltage (output)\u003c\/dt\u003e\n\u003cdd\u003e16,8 V¦31,2 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eProduct Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct information\u003c\/dt\u003e\n\u003cdd\u003eThe ACT20M-RTCI-CO-OLP-S passive configurable temperature transducer isolates and converts analogue signals. An analogue RTD (Type Pt100) or TC (Type J, K) input signal is linearly converted into an analogue output signal and galvanically isolated. Power is supplied through the output measurement circuit (output- loop powered).\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironmental Product Compliance\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eREACH SVHC\u003c\/dt\u003e\n\u003cdd\u003eLead 7439-92-1\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eData For Ex Applications (Atex)\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMarking\u003c\/dt\u003e\n\u003cdd\u003eII 3 G Ex nA IIC T4 Gc\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eInsulation Coordination\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEMC standards\u003c\/dt\u003e\n\u003cdd\u003eIEC 61326-1, NE 21\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eGalvanic isolation\u003c\/dt\u003e\n\u003cdd\u003e2-way isolator\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInsulation voltage\u003c\/dt\u003e\n\u003cdd\u003e2.5 kVeff \/1 min.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePollution severity\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated voltage\u003c\/dt\u003e\n\u003cdd\u003e300 Veff\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSurge voltage category\u003c\/dt\u003e\n\u003cdd\u003eII\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eTemperatures\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHumidity\u003c\/dt\u003e\n\u003cdd\u003e40°C \/ 93 % rel. humidity, no condensation\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStorage temperature, max.\u003c\/dt\u003e\n\u003cdd\u003e85 °C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStorage temperature, min.\u003c\/dt\u003e\n\u003cdd\u003e-40 °C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature\u003c\/dt\u003e\n\u003cdd\u003e-25°C...+70°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStorage temperature\u003c\/dt\u003e\n\u003cdd\u003e-40°C...85°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eRatings Iecex\/Atex\/Cul\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCertificate No. (ATEX)\u003c\/dt\u003e\n\u003cdd\u003eKEMA10ATEX0183X\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCertificate No. (IECEX)\u003c\/dt\u003e\n\u003cdd\u003eIECEXKEM10.0090X\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCertificate no. (cULus)\u003c\/dt\u003e\n\u003cdd\u003eE337701\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49074639372573,"sku":"DA-385331","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/weidmuller-1435590000-dropship-automation.webp?v=1753839361","url":"https:\/\/dropshipautomation.com\/products\/weidmuller-1435590000","provider":"Dropship Automation","version":"1.0","type":"link"}