{"product_id":"wago-750-872","title":"WAGO 750-872","description":"\u003ch2 class=\" \"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e750-872\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eUPC\u003c\/dt\u003e\n\u003cdd\u003e4045454618186\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTariff Code\u003c\/dt\u003e\n\u003cdd\u003e85371091990\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\"grid items-center gap-x-4 px-4  \"\u003e\n\u003cdt\u003eETIM\u003c\/dt\u003e\n\u003cdd\u003e\u003cdl\u003e\n\u003cdiv class=\" \"\u003e\u003cdd\u003eGroup Code : EG000024\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\u003cdd\u003eGroup Description : PLC's\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\u003cdd\u003eClass Description : PLC CPU-module\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\u003cdd\u003eClass Code : EC000236\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\u003cdd\u003eVersion : 7\u003c\/dd\u003e\u003c\/div\u003e\n\u003c\/dl\u003e\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\" \"\u003eEnvironmental Requirements\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAmbient temperature (operation)\u003c\/dt\u003e\n\u003cdd\u003e0 … +55°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAmbient temperature (storage)\u003c\/dt\u003e\n\u003cdd\u003e-25 … +85°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eProtection type\u003c\/dt\u003e\n\u003cdd\u003eIP20\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePollution degree\u003c\/dt\u003e\n\u003cdd\u003e2 per IEC 61131-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eOperating altitude\u003c\/dt\u003e\n\u003cdd\u003eWithout temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K\/100 m); 5000 m (max.)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eRelative humidity (without condensation)\u003c\/dt\u003e\n\u003cdd\u003e95 %\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMounting position\u003c\/dt\u003e\n\u003cdd\u003eAny\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMounting type\u003c\/dt\u003e\n\u003cdd\u003eDIN-35 rail\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eVibration resistance\u003c\/dt\u003e\n\u003cdd\u003ePer IEC 60068-2-6\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eShock resistance\u003c\/dt\u003e\n\u003cdd\u003e15g per IEC 60068-2-27\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eEMC immunity to interference\u003c\/dt\u003e\n\u003cdd\u003ePer EN 61000-6-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eEMC emission of interference\u003c\/dt\u003e\n\u003cdd\u003ePer EN 61000-6-4\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eExposure to pollutants\u003c\/dt\u003e\n\u003cdd\u003ePer IEC 60068-2-42 and IEC 60068-2-43\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eFire load\u003c\/dt\u003e\n\u003cdd\u003e3.782 MJ\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePermissible H2S contaminant concentration at a relative humidity 75 %\u003c\/dt\u003e\n\u003cdd\u003e10 ppm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePermissible SO2 contaminant concentration at a relative humidity 75 %\u003c\/dt\u003e\n\u003cdd\u003e25 ppm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eConnection Data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eConnection technology: communication\/fieldbus\u003c\/dt\u003e\n\u003cdd\u003eEtherNet\/IPTM: 1 x RJ-45; Modbus (TCP, UDP): 1 x RJ-45; Modbus® RTU: 1 x D-sub 9 socket; RS-232 serial interface: 1 x D-sub 9 socket; Telecontrol protocol IEC 60870-5-101\/-103: 1 x D-sub 9 socket; Telecontrol protocol IEC 60870-5-104: 1 x RJ-45; Telecontrol protocol IEC 61850: 1 x RJ-45; Telecontrol protocol DNP3: 1 x RJ-45 or D-sub 9 socket\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eConnection technology: system supply\u003c\/dt\u003e\n\u003cdd\u003e2 x CAGE CLAMP®\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eConnection technology: field supply\u003c\/dt\u003e\n\u003cdd\u003e6 x CAGE CLAMP®\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eConnection type 1\u003c\/dt\u003e\n\u003cdd\u003eSystem\/field supply\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eSolid conductor\u003c\/dt\u003e\n\u003cdd\u003e0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eFine-stranded conductor\u003c\/dt\u003e\n\u003cdd\u003e0.08 … 2.5 mm² \/ 28 … 14 AWG\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eStrip length\u003c\/dt\u003e\n\u003cdd\u003e8 … 9 mm \/ 0.31 … 0.35 inches\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eConnection technology: device configuration\u003c\/dt\u003e\n\u003cdd\u003e1 x Male connector; 4-pole\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003ePhysical Data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e50.5 mm \/ 1.988 inches\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e71.1 mm \/ 2.799 inches\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eHeight from upper-edge of DIN-rail\u003c\/dt\u003e\n\u003cdd\u003e63.9 mm \/ 2.516 inches\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e100 mm \/ 3.937 inches\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eTechnical Data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCommunication\u003c\/dt\u003e\n\u003cdd\u003eEtherNet\/IPTM || Modbus (TCP, UDP) || ETHERNET || Modbus® RTU || Telecontrol protocols || RS-232 serial interface\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eETHERNET protocols\u003c\/dt\u003e\n\u003cdd\u003eHTTP || BootP || DHCP || DNS || NTP || SNTP || FTP || SNMP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTelecontrol protocols\u003c\/dt\u003e\n\u003cdd\u003eIEC 60870-5-101\/-103\/-104 || 3964R\/RK512 || IEC 61850-7 || IEC 61400-25 || DNP3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eVisualization\u003c\/dt\u003e\n\u003cdd\u003eWeb-Visu\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCPU\u003c\/dt\u003e\n\u003cdd\u003e32 bits\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eProgramming languages per IEC 61131-3\u003c\/dt\u003e\n\u003cdd\u003eInstruction List (IL) || Ladder Diagram (LD) || Function Block Diagram (FBD) || Continuous Function Chart (CFC) || Structured Text (ST) || Sequential Function Chart (SFC)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eProgramming environment\u003c\/dt\u003e\n\u003cdd\u003eWAGO-I\/O-PRO V2.3 (based on CODESYS V2.3)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eConfiguration options\u003c\/dt\u003e\n\u003cdd\u003eWAGO-I\/O-CHECK || Web-Based Management\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eDevice specification\u003c\/dt\u003e\n\u003cdd\u003eFunction per IEC 60870-5-101 and -104 library: Client and server; Function per IEC 61850 and 61400-25 library: Server; Conformity document: see www.wago.com\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eLibraries\u003c\/dt\u003e\n\u003cdd\u003eIEC 60870-5-101\/-103\/-104, 3964R\/RK512, IEC 61850, IEC 61400-25, DNP3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eBaud rate (communication\/fieldbus 1)\u003c\/dt\u003e\n\u003cdd\u003e10\/100 Mbit\/s\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eBaud rate (communication\/fieldbus 2)\u003c\/dt\u003e\n\u003cdd\u003e9.6 kBd … 115.2 kBd\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eBaud rate\u003c\/dt\u003e\n\u003cdd\u003eETHERNET: 10\/100 Mbit\/s; Serial interface: 9.6 kBd … 115.2 kBd\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eBus segment length (max.)\u003c\/dt\u003e\n\u003cdd\u003eETHERNET: 100 m; Serial interface: 1200 m\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTransmission medium (communication\/fieldbus)\u003c\/dt\u003e\n\u003cdd\u003eETHERNET: Twisted pair S-UTP; 100 ?; Cat. 5; Serial interface: Shielded Cu cable 2 (4) x 0.25 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eInternal memory (flash)\u003c\/dt\u003e\n\u003cdd\u003e2 MB\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eProgram memory\u003c\/dt\u003e\n\u003cdd\u003e1024 KB\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eData memory\u003c\/dt\u003e\n\u003cdd\u003e1024 KB\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eNon-volatile software memory\u003c\/dt\u003e\n\u003cdd\u003e30 KB\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMemory for fieldbus input variables (max.)\u003c\/dt\u003e\n\u003cdd\u003e512 bytes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMemory for fieldbus output variables (max.)\u003c\/dt\u003e\n\u003cdd\u003e512 bytes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eNumber of modules per node (max.)\u003c\/dt\u003e\n\u003cdd\u003e250\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eNumber of modules without a bus extension (max.)\u003c\/dt\u003e\n\u003cdd\u003e64\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eNumber of information objects\u003c\/dt\u003e\n\u003cdd\u003e150\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eNumber of control stations\u003c\/dt\u003e\n\u003cdd\u003e4\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eInput and output process image (fieldbus) max.\u003c\/dt\u003e\n\u003cdd\u003e1953.125 bytes\/1953.125 bytes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eIndicators\u003c\/dt\u003e\n\u003cdd\u003eLED (LINK) green: Network connection LED (MS, NS) red\/green: Status of node, network; LED (TxD\/RxD) green: data exchange; LED (I\/O, USR) red\/green\/orange: Local data bus status, status programmable by user; LED (A, B) green: System power supply status, field supply\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eSupply voltage (system)\u003c\/dt\u003e\n\u003cdd\u003e24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP® connection)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eInput current (typ.) at nominal load (24 V)\u003c\/dt\u003e\n\u003cdd\u003e500 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePower supply efficiency (typ.) at nominal load (24 V)\u003c\/dt\u003e\n\u003cdd\u003e87 %\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCurrent consumption (5 V system supply)\u003c\/dt\u003e\n\u003cdd\u003e300 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTotal current (system supply)\u003c\/dt\u003e\n\u003cdd\u003e1700 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eSupply voltage (field)\u003c\/dt\u003e\n\u003cdd\u003e24 VDC (-25 … +30 %); via power jumper contacts\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCurrent carrying capacity (power jumper contacts)\u003c\/dt\u003e\n\u003cdd\u003e10 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eNumber of outgoing power jumper contacts\u003c\/dt\u003e\n\u003cdd\u003e3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eIsolation\u003c\/dt\u003e\n\u003cdd\u003e500 V system\/field\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eMechanical Data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eWeight\u003c\/dt\u003e\n\u003cdd\u003e193.358 g\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eColor\u003c\/dt\u003e\n\u003cdd\u003eLight gray\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eHousing material\u003c\/dt\u003e\n\u003cdd\u003ePolycarbonate; polyamide 6.6\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eConformity marking\u003c\/dt\u003e\n\u003cdd\u003eCE\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eConformity document\u003c\/dt\u003e\n\u003cdd\u003eSee www.wago.com\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eProduct Group Code\u003c\/dt\u003e\n\u003cdd\u003e0015\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\" \"\u003eCommercial Data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePackaging type\u003c\/dt\u003e\n\u003cdd\u003eBox\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCountry of origin\u003c\/dt\u003e\n\u003cdd\u003eDE\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eGTIN\u003c\/dt\u003e\n\u003cdd\u003e4045454618186\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCustoms tariff number\u003c\/dt\u003e\n\u003cdd\u003e85371091990\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49464574673181,"sku":"DA-759995","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/dropship-automation_75b74988-dcae-4249-bee8-1c9430812565.webp?v=1734331870","url":"https:\/\/dropshipautomation.com\/products\/wago-750-872","provider":"Dropship Automation","version":"1.0","type":"link"}