{"product_id":"wago-750-489","title":"WAGO 750-489","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e750-489\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUPC\u003c\/dt\u003e\n\u003cdd\u003e4055143948029\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTariff Code\u003c\/dt\u003e\n\u003cdd\u003e85389099990\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\"grid items-center gap-x-4 px-4 \"\u003e\n\u003cdt\u003eETIM\u003c\/dt\u003e\n\u003cdd\u003e\u003cdl\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eGroup Code : EG000024\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eGroup Description : PLC's\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eClass Description : Fieldbus, decentr. periphery - analogue I\/O module\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eClass Code : EC001596\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eVersion : 7\u003c\/dd\u003e\u003c\/div\u003e\n\u003c\/dl\u003e\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironmental Requirements\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature (operation)\u003c\/dt\u003e\n\u003cdd\u003e0 ¦ +55°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature (storage)\u003c\/dt\u003e\n\u003cdd\u003e-25 ¦ +85°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtection type\u003c\/dt\u003e\n\u003cdd\u003eIP20\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePollution degree\u003c\/dt\u003e\n\u003cdd\u003e2 per IEC 61131-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating altitude\u003c\/dt\u003e\n\u003cdd\u003e0 ¦ 2000 m \/ 0 ¦ 6562 ft\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting position\u003c\/dt\u003e\n\u003cdd\u003eHorizontal (standing\/lying); vertical\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRelative humidity (without condensation)\u003c\/dt\u003e\n\u003cdd\u003e95 %\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVibration resistance\u003c\/dt\u003e\n\u003cdd\u003e4g per IEC 60068-2-6\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShock resistance\u003c\/dt\u003e\n\u003cdd\u003e15g per IEC 60068-2-27\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEMC immunity to interference\u003c\/dt\u003e\n\u003cdd\u003ePer EN 61000-6-2, marine applications\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEMC emission of interference\u003c\/dt\u003e\n\u003cdd\u003ePer EN 61000-6-3, marine applications\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eExposure to pollutants\u003c\/dt\u003e\n\u003cdd\u003ePer IEC 60068-2-42 and IEC 60068-2-43\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eConnection Data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection technology: inputs\/outputs\u003c\/dt\u003e\n\u003cdd\u003e16 x CAGE CLAMP®\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection type 1\u003c\/dt\u003e\n\u003cdd\u003eInputs\/outputs\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSolid conductor\u003c\/dt\u003e\n\u003cdd\u003e0.08 ¦ 2.5 mm² \/ 28 ¦ 14 AWG\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFine-stranded conductor\u003c\/dt\u003e\n\u003cdd\u003e0.08 ¦ 2.5 mm² \/ 28 ¦ 14 AWG\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStrip length\u003c\/dt\u003e\n\u003cdd\u003e8 ¦ 9 mm \/ 0.31 ¦ 0.35 inches\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003ePhysical Data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e24 mm \/ 0.945 inches\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e100 mm \/ 3.937 inches\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e67.8 mm \/ 2.669 inches\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth from upper-edge of DIN-rail\u003c\/dt\u003e\n\u003cdd\u003e60.6 mm \/ 2.386 inches\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eMaterial Data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHousing material\u003c\/dt\u003e\n\u003cdd\u003ePolycarbonate; polyamide 6.6\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFire load\u003c\/dt\u003e\n\u003cdd\u003e2.036 MJ\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWeight\u003c\/dt\u003e\n\u003cdd\u003e99.300 g\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConformity marking\u003c\/dt\u003e\n\u003cdd\u003eCE\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eTechnical Data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of analog inputs\u003c\/dt\u003e\n\u003cdd\u003e4\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTotal number of channels (module)\u003c\/dt\u003e\n\u003cdd\u003e4\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSignal type\u003c\/dt\u003e\n\u003cdd\u003ePotentiometer positions || Thermocouple || Resistive temperature device || Resistors || MV encoder\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSignal type (configurable)\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSensor connection\u003c\/dt\u003e\n\u003cdd\u003e4 x (2-wire); RTD\/R: 3-wire; 4-wire\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eData width\u003c\/dt\u003e\n\u003cdd\u003e4 x 16-bit data; 4 x 8-bit control\/status (optional)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResolution (over entire range)\u003c\/dt\u003e\n\u003cdd\u003e0.1 K of full scale value; 0.01 K of full scale value (restricted to -50°C ¦ +150°C)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConversion time\u003c\/dt\u003e\n\u003cdd\u003e ¥10 ms\/2 wires (per channel)*;  ¥20 ms\/3 wires, 4 wires (per channel)*; *for RTD\/R; TC\/U conversion time depends on module setting\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMeasurement error (25°C)\u003c\/dt\u003e\n\u003cdd\u003eIn delivery state: ±0.2 % of the upper-range value (value achieved during calibration in operating environment 0  ¤ TA  ¤ 55°C); After user calibration: ±0.05 % of the upper-range value (only valid in the thermally stable operating state)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTemperature coefficient\u003c\/dt\u003e\n\u003cdd\u003e±0.001 %\/K of the upper-range value\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIntrinsic safety Ex i\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMeasurement range\u003c\/dt\u003e\n\u003cdd\u003eResistive temperature devices: Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Ni1000-TK5000; Resistors: 250 ©, 500 ©, 1 k©, 2 k©, 4 k©, PTC; Potentiometer setting: 0 ¦ 100 %; Thermocouples: Type B (+250 ¦ +1,820°C); Type C (0 ¦ +2,315°C); Type E (-200 ¦ +1,000°C); Type J (-210 ¦ +1,200°C); Type K (-200 ¦ +1,372°C); Type N (-200 ¦ +1,300°C); Type R, S (-50 ¦ +1,768°C); Type T (-200 ¦ +400°C); mV sensors: ±30 mV; ±60 mV; ±120 mV; ±250 mV; ±500 mV; ±1,000 mV; ±2,000 mV; Thermistor: PTC; Resistor bridges (strain gauges): Uref: 2.4 V; Ud: ±15 mV, ±30 mV, ±60 mV\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCold junction compensation\u003c\/dt\u003e\n\u003cdd\u003eIntegrated\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConfiguration options\u003c\/dt\u003e\n\u003cdd\u003eWAGO-I\/O-CHECK || CODESYS Library || e!COCKPIT\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply voltage (system)\u003c\/dt\u003e\n\u003cdd\u003e5 VDC; via data contacts\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent consumption (5 V system supply)\u003c\/dt\u003e\n\u003cdd\u003e60 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply voltage (field)\u003c\/dt\u003e\n\u003cdd\u003e24 VDC; (Ex i power supply: UO = max. 27.3 V); via power jumper contacts (power supply via blade contact; transmission via spring contact)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent consumption, field supply (module with no external load)\u003c\/dt\u003e\n\u003cdd\u003e120 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower loss Pl\u003c\/dt\u003e\n\u003cdd\u003e1.6 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIsolation\u003c\/dt\u003e\n\u003cdd\u003ePer EN\/IEC 60079-11: 300 VAC system\/supply; per EN\/UL 61010-2-201: 1200 VDC system\/supply\/channel\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIndicators\u003c\/dt\u003e\n\u003cdd\u003eLED (A, C, E, G) green: Function AI 1 ¦ AI 4; LED (B, D, F, H) red: Error AI 1 ¦ AI 4\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of incoming power jumper contacts\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of outgoing power jumper contacts\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMarking\u003c\/dt\u003e\n\u003cdd\u003eATEX\/IECEx: II 3 (1) G Ex ec [ia Ga] IIC T4 Gc; II (1) D [Ex ia Da] IIIC; I (M1) [Ex ia Ma] I\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eMechanical Data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting type\u003c\/dt\u003e\n\u003cdd\u003eDIN-35 rail\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Group Code\u003c\/dt\u003e\n\u003cdd\u003e0015\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eCommercial Data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePackaging type\u003c\/dt\u003e\n\u003cdd\u003eBox\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCountry of origin\u003c\/dt\u003e\n\u003cdd\u003eDE\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eGTIN\u003c\/dt\u003e\n\u003cdd\u003e4055143948029\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCustoms tariff number\u003c\/dt\u003e\n\u003cdd\u003e85389099990\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eNotes\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNote\u003c\/dt\u003e\n\u003cdd\u003eThe analog input module must only be operated via 24 VDC Ex i!General information (e.g., installation regulations) on explosion protection is available in the WAGO I\/O System 750 manuals!\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eExplosion Protection\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEx standard\u003c\/dt\u003e\n\u003cdd\u003eEN IEC 60079-0, -7, -11\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSafety-relevant data (circuit)\u003c\/dt\u003e\n\u003cdd\u003eUo = 4 V; Io = 13.46 mA; Po = 13.46 mW; linear characteristic curve\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReactances Ex ia IIC\u003c\/dt\u003e\n\u003cdd\u003eLo = 0.19 H; Co = 100 µF\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReactances Ex ia IIB\u003c\/dt\u003e\n\u003cdd\u003eLo = 0.78 H; Co = 1000 µF\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReactances Ex ia IIA\u003c\/dt\u003e\n\u003cdd\u003eLo = 1.57 H; Co = 1000 ¼F\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReactances Ex ia I\u003c\/dt\u003e\n\u003cdd\u003eLo = 2.57 H; Co = 1000 µF\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReactances (note)\u003c\/dt\u003e\n\u003cdd\u003eReactances, if the internal inductance Li or capacitance Ci (without cable) of the connected device is  ¤1 % of the specified values.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49118310727965,"sku":"DA-540238","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/dropship-automation_3432a0fd-d174-4fd2-9c57-97567b35f7b7.webp?v=1731743371","url":"https:\/\/dropshipautomation.com\/products\/wago-750-489","provider":"Dropship Automation","version":"1.0","type":"link"}