Additional Information
- Part Number
- SMART2200NET
- UPC
- 037332032041
Overview
- UPC Code
- 037332032041
- UPS Type
- Line-Interactive
Output
- Output Volt Amp Capacity (VA)
- 2200
- Output kVA Capacity (kVA)
- 2.2
- Output Watt Capacity (Watts)
- 1700
- Output kW Capacity (kW)
- 1.7
- Power Factor
- 0.8
- Nominal Voltage Details
- 120v nominal output in battery mode
- Frequency Compatibility
- 60 Hz
- Output Voltage Regulation (Line Mode)
- -13% / +5%
- Output Voltage Regulation (Battery Mode)
- +/- 5%
- Load Management Receptacles
- Two switchable single outlet 5-15R load banks
- Output AC Waveform (AC Mode)
- Sine wave
- Output AC Waveform (Battery Mode)
- PWM sine wave
- Output Capacity Details
- Output is reduced to 1200W maximum with 1-2 external battery packs and 800W maximum with 3 or more external battery packs
- Nominal Output Voltage(s) Supported
- 110V; 115V; 120V
- Output Receptacles
- (6) 5-15R
- Individually Controllable Load Banks
- Yes
Input
- Rated input current (Maximum Load)
- 15A
- Nominal Input Voltage(s) Supported
- 120V AC
- UPS Input Connection Type
- 5-15P
- Input Circuit Breakers
- 20A
- UPS Input Cord Length (ft.)
- 8
- Recommended Electrical Service
- 20A 120V
- Input Phase
- Single-Phase
- Input Cord Length (ft.)
- 8
Battery
- Full Load Runtime (min.)
- 11 min. (1700w)
- Half Load Runtime (min.)
- 27 min. (850w)
- Expandable Battery Runtime
- Extended runtime supported via optional external battery packs
- External Battery Pack Compatibility
- BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible)
- DC System Voltage (VDC)
- 24
- Battery Recharge Rate (Included Batteries)
- Less than 9 hours from 10% to 90% (typical, full load discharge)
- Expandable Runtime
- Yes
Voltage Regulation
- Voltage Regulation Description
- Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 87 to 140
- Overvoltage Correction
- Input voltages between 127 and 140 are reduced by 12%
- Undervoltage Correction
- Input voltages between 95 and 105 are boosted by 10%
- Severe Undervoltage Correction
- Input voltages between 87 and 94 are boosted by 22%
User Interface, Alerts & Controls
- Switches
- 2 Switches control off/on power status and alarm-cancel/self-test operation; set of 4 rear-panel switches control system enable and contact closure port inverter shutoff commands
- Alarm Cancel Operation
- Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
- Audible Alarm
- Audible alarm indicates power-failure and low-battery conditions
- LED Indicators
- 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 720
- UPS AC Suppression Response Time
- Instantaneous
- EMI / RFI AC Noise Suppression
- Yes
Physical
- Primary Form Factor
- Tower
- Primary UPS Depth (mm)
- 318
- Primary UPS Height (mm)
- 432
- Primary UPS Width (mm)
- 229
- Shipping Dimensions (hwd / in.)
- 13.75 x 16.50 x 22.50
- Shipping Weight (lbs.)
- 81.00
- UPS Housing Material
- Polycarbonate
- UPS Power Module Dimensions (hwd, in.)
- 17 x 9 x 12.5
- UPS Power Module Weight (kg)
- 36.29
- UPS Power Module Weight (lbs.)
- 80
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity
- 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 59
- Battery Mode BTU / Hr. (Full Load)
- 867
- AC Mode Efficiency Rating (100% Load)
- 99%
Communications
- Network Monitoring Port Description
- Supports detailed monitoring of UPS and site power conditions; contact closure communications via two additional DB9 ports (3 total)
- PowerAlert Software
- For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable
- 3 DB9 cables included
- Communications Interface
- DB9 Serial; Contact closure
Line / Battery Transfer
- Transfer Time
- 2-4 milliseconds
- Low Voltage Transfer to Battery Power (Setpoint)
- 87
- High Voltage Transfer to Battery Power (Setpoint)
- 140
Special Features
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
Certifications
- UPS Certifications
- Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
Warranty
- Product Warranty Period (Worldwide)
- 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.
- Connected Equipment Insurance (U.S., Canada & Puerto Rico)
- $250,000 Ultimate Lifetime Insurance