{"product_id":"tripp-lite-pdumh32hvnet","title":"TRIPP-LITE PDUMH32HVNET","description":"\u003ch2 class=\" \"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003ePDUMH32HVNET\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eUPC\u003c\/dt\u003e\n\u003cdd\u003e037332157249\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eOverview\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eUPC Code\u003c\/dt\u003e\n\u003cdd\u003e037332157249\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePDU Type\u003c\/dt\u003e\n\u003cdd\u003eSwitched\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eOutput\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eFrequency Compatibility\u003c\/dt\u003e\n\u003cdd\u003e50 \/ 60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eOutput Capacity Details\u003c\/dt\u003e\n\u003cdd\u003e7.4kW (230V) \/ 32A total capacity \/ 20A max per breakered outlet bank; 16A max per C19 outlet, 10A max per C13 outlet\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eOutput Receptacles\u003c\/dt\u003e\n\u003cdd\u003e(16) C13\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eOutput Nominal Voltage\u003c\/dt\u003e\n\u003cdd\u003e230\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eOverload Protection\u003c\/dt\u003e\n\u003cdd\u003eTwo 20A circuit breakers protect 8 outlets each\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCustomized Load Management Receptacles\u003c\/dt\u003e\n\u003cdd\u003eEach outlet is individually controllable via remote interface\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eInput\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eNominal Input Voltage(s) Supported\u003c\/dt\u003e\n\u003cdd\u003e230V AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePDU Input Voltage\u003c\/dt\u003e\n\u003cdd\u003e230\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eRecommended Electrical Service\u003c\/dt\u003e\n\u003cdd\u003e32A 230V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMaximum Input Amps\u003c\/dt\u003e\n\u003cdd\u003e32\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePDU Plug Type\u003c\/dt\u003e\n\u003cdd\u003eIEC-309 32A BLUE (2P+E)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eInput Phase\u003c\/dt\u003e\n\u003cdd\u003eSingle-Phase\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eInput Cord Length (ft.)\u003c\/dt\u003e\n\u003cdd\u003e12\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eUser Interface, Alerts \u0026amp; Controls\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eFront Panel LCD Display\u003c\/dt\u003e\n\u003cdd\u003eDigital display reports output amps in 3 loading segments (BANK 1: Outlets #1-8; BANK 2: Outlets #9-16; BANK 3: All outlets combined)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eFront Panel LEDs\u003c\/dt\u003e\n\u003cdd\u003e16 power availability LEDs confirm power off\/on status for each built-in outlet; Two additional LEDs identify which bank the visual current meter is reporting (Bank 1, Bank 2 or Banks 1\u0026amp;2 combined); WEBCARDLX: LX Platform Status LED (Green); Network Link\/Activity LED (Yellow), Network Speed LED (Green)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eSwitches\u003c\/dt\u003e\n\u003cdd\u003ePushbutton near the digital current meter advances the display of output current for Bank 1, Bank 2 and Banks 1\u0026amp;2 combined; WEBCARDLX : Recessed reset switch for card reboot and factory reset\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003ePhysical\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eForm Factors Supported\u003c\/dt\u003e\n\u003cdd\u003e2U rackmount\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMaterial of Construction\u003c\/dt\u003e\n\u003cdd\u003eMetal\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMinimum Required Rack Depth (inches)\u003c\/dt\u003e\n\u003cdd\u003e14.8\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePDU Form Factor\u003c\/dt\u003e\n\u003cdd\u003eHorizontal (2U)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eShipping Dimensions (hwd \/ in.)\u003c\/dt\u003e\n\u003cdd\u003e7.70 x 16.90 x 19.70\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eShipping Weight (lbs.)\u003c\/dt\u003e\n\u003cdd\u003e16.40\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eUnit Dimensions (hwd \/ in.)\u003c\/dt\u003e\n\u003cdd\u003e3.5 x 17.5 x 12.5\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eUnit Weight (lbs.)\u003c\/dt\u003e\n\u003cdd\u003e13.7\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eEnvironmental\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eStorage Temperature Range\u003c\/dt\u003e\n\u003cdd\u003e-30°C to +50°C (-22°F to +122°F)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eRelative Humidity\u003c\/dt\u003e\n\u003cdd\u003eUp to 95% non-condensing\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eCommunications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eSNMP Compatibility\u003c\/dt\u003e\n\u003cdd\u003eLX platform interface provides remote monitoring and control via Java-free HTML5 web interface, telnet, SSH and SNMP management systems\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\" \"\u003eCertifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCertifications\u003c\/dt\u003e\n\u003cdd\u003eTested to CE (IEC 60950-1), EN Class A (Emissions), RoHS compliant, TAA Compliant\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\" \"\u003eWarranty\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eProduct Warranty Period (Worldwide)\u003c\/dt\u003e\n\u003cdd\u003e2-year limited warranty\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49484050170141,"sku":"DA-866863","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/dropship-automation_79ca8dc8-fbdd-40a7-ab8d-299c6652a2b2.webp?v=1734769389","url":"https:\/\/dropshipautomation.com\/products\/tripp-lite-pdumh32hvnet","provider":"Dropship Automation","version":"1.0","type":"link"}