{"product_id":"socomec-41502022","title":"SOCOMEC 41502022","description":"\u003ch2 class=\" \"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e41502022\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCountry of Origin\u003c\/dt\u003e\n\u003cdd\u003eFrance\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eCertificates and Declaration\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eConformity to standard #1\u003c\/dt\u003e\n\u003cdd\u003eUL1008\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eConformity to standard #4\u003c\/dt\u003e\n\u003cdd\u003eE317092 Vol.1 Sec.7\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eProposition 65 California\u003c\/dt\u003e\n\u003cdd\u003eWARNING This product can expose you to chemicals including Styrene, which is known to the State of California to cause cancer. For more information go to : www.P65Warnings.ca.gov\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eMechanical Characteristics\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eEndurance (number of operating cycles)\u003c\/dt\u003e\n\u003cdd\u003e6050\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\" \"\u003eShort-Circuit Capacity\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMax fuse rating (A)\u003c\/dt\u003e\n\u003cdd\u003e400\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eShort circuit rating at 600 VAC (kA)\u003c\/dt\u003e\n\u003cdd\u003e100\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eType of fuse\u003c\/dt\u003e\n\u003cdd\u003eJ\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eConnection Terminals\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMax. connection section \/ AWG\u003c\/dt\u003e\n\u003cdd\u003e300MCM\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMin. connection section \/ AWG\u003c\/dt\u003e\n\u003cdd\u003e#6\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCountry of Origin\u003c\/dt\u003e\n\u003cdd\u003eFrance\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eShort circuit rating at 600 VAC with “Any Breaker” (kA) \/ Short circuit capacity (ms)\u003c\/dt\u003e\n\u003cdd\u003e25\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eShort circuit rating at 600 VAC with “Any Breaker” (kA) \/ Short circuit rating (kA)\u003c\/dt\u003e\n\u003cdd\u003e10\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eShort circuit rating at with Square D JJ breaker 250 A - 2 P 240 VAC - 3\/4 P 480 VAC (kA)\u003c\/dt\u003e\n\u003cdd\u003e65\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAuxiliary contacts \/ Electrical characteristics\u003c\/dt\u003e\n\u003cdd\u003eAC300\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eNumber of Poles\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eOperation voltage 2 P - 3\/4 P\u003c\/dt\u003e\n\u003cdd\u003e240\/600\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eRated operational current \/ 240 VAC resistive load (A)\u003c\/dt\u003e\n\u003cdd\u003e200\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eRated operational current \/ 240 VAC “Total System” (A)\u003c\/dt\u003e\n\u003cdd\u003e200\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eRated operational current \/ 480 VAC resistive load (A)\u003c\/dt\u003e\n\u003cdd\u003e200\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eRated operational current \/ 480 VAC “Total System” (A)\u003c\/dt\u003e\n\u003cdd\u003e100\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eRated operational current \/ 600 VAC resistive load (A)\u003c\/dt\u003e\n\u003cdd\u003e200\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eRated operational current \/ 600 VAC “Total System” (A)\u003c\/dt\u003e\n\u003cdd\u003e100\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eUL General use rating (A)\u003c\/dt\u003e\n\u003cdd\u003e200\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49494389555485,"sku":"DA-917472","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/dropship-automation_d5ad708b-0ba6-44e4-aa98-1ae7ebd32943.webp?v=1735057598","url":"https:\/\/dropshipautomation.com\/products\/socomec-41502022","provider":"Dropship Automation","version":"1.0","type":"link"}