{"product_id":"siemens-6gk1561-3aa02-1","title":"SIEMENS 6GK1561-3AA02","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e6GK1561-3AA02\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUPC\u003c\/dt\u003e\n\u003cdd\u003e887621498320\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature during operation maximum [°C]\u003c\/dt\u003e\n\u003cdd\u003e55\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature during operation minimum [°C]\u003c\/dt\u003e\n\u003cdd\u003e5\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature during storage maximum [°C]\u003c\/dt\u003e\n\u003cdd\u003e60\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature during storage minimum [°C]\u003c\/dt\u003e\n\u003cdd\u003e-20\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature during transport maximum [°C]\u003c\/dt\u003e\n\u003cdd\u003e60\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature during transport minimum [°C]\u003c\/dt\u003e\n\u003cdd\u003e-20\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmount of data of the address area of the diagnostic data per DP slave [byte]\u003c\/dt\u003e\n\u003cdd\u003e244\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmount of data of the address area of the inputs as DP master total [byte]\u003c\/dt\u003e\n\u003cdd\u003e30256\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmount of data of the address area of the inputs as DP slave total [byte]\u003c\/dt\u003e\n\u003cdd\u003e244\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmount of data of the address area of the inputs per DP slave [byte]\u003c\/dt\u003e\n\u003cdd\u003e244\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmount of data of the address area of the outputs as DP master total [byte]\u003c\/dt\u003e\n\u003cdd\u003e30256\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmount of data of the address area of the outputs as DP slave total [byte]\u003c\/dt\u003e\n\u003cdd\u003e244\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmount of data of the address area of the outputs per DP slave [byte]\u003c\/dt\u003e\n\u003cdd\u003e244\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCertificate of suitability C-Tick\u003c\/dt\u003e\n\u003cdd\u003eyes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCertificate of suitability CE marking\u003c\/dt\u003e\n\u003cdd\u003eyes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConfiguration software required\u003c\/dt\u003e\n\u003cdd\u003eIncluded in scope of supply\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConsumed current 1 from backplane bus at DC maximum [A]\u003c\/dt\u003e\n\u003cdd\u003e0.15\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConsumed current 2 from backplane bus at DC maximum [A]\u003c\/dt\u003e\n\u003cdd\u003e0.25\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth [mm]\u003c\/dt\u003e\n\u003cdd\u003e125\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesign of the interface 10 Gigabit Ethernet interface\u003c\/dt\u003e\n\u003cdd\u003eno\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesign of the interface Ethernet interface\u003c\/dt\u003e\n\u003cdd\u003eno\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesign of the interface Fast Ethernet interface\u003c\/dt\u003e\n\u003cdd\u003eno\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesign of the interface Gigabit Ethernet interface\u003c\/dt\u003e\n\u003cdd\u003eno\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight [mm]\u003c\/dt\u003e\n\u003cdd\u003e107\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInternet-Link to website: CAx Download Manager\u003c\/dt\u003e\n\u003cdd\u003ehttp:\/\/www.siemens.com\/cax\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInternet-Link to website: Image database\u003c\/dt\u003e\n\u003cdd\u003ehttp:\/\/automation.siemens.com\/bilddb\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInternet-Link to website: Industrial communication\u003c\/dt\u003e\n\u003cdd\u003ehttp:\/\/www.siemens.com\/simatic-net\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInternet-Link to website: Industry Mall\u003c\/dt\u003e\n\u003cdd\u003ehttp:\/\/www.siemens.com\/industrial-controls\/mall\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInternet-Link to website: Industry Online Support\u003c\/dt\u003e\n\u003cdd\u003ehttps:\/\/support.industry.siemens.com\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInternet-Link to website: Information and Download Center\u003c\/dt\u003e\n\u003cdd\u003ehttp:\/\/www.siemens.com\/industry\/infocenter\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInternet-Link to website: Selector SIMATIC NET SELECTION TOOL\u003c\/dt\u003e\n\u003cdd\u003ehttp:\/\/www.siemens.com\/snst\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eModule format\u003c\/dt\u003e\n\u003cdd\u003ePCI\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNet weight [kg]\u003c\/dt\u003e\n\u003cdd\u003e0.098\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 10 Gbit\/s SC ports (SR)\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 10 Mbit\/s AUI ports\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 10 Mbit\/s BNC ports\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 10 Mbit\/s RJ45 ports\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 10 Mbit\/s SC ports\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 10 Mbit\/s ST(BFOC) ports\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 10\/100 Mbit\/s RJ45 ports\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 10\/100\/1000 Mbit\/s RJ45 ports\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 100 Mbit\/s MT-RJ ports\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 100 Mbit\/s SC ports for multimode Integrated\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 100 Mbit\/s VF-45 ports\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 100\/1000 Mbit\/s RJ45 ports\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 1000 Mbit\/s MT-RJ ports\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 1000 Mbit\/s SC ports (LX)\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 1000 Mbit\/s SC ports (SX)\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of 1000 Mbit\/s VF-45 ports\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of active connections with multi-protocol mode\u003c\/dt\u003e\n\u003cdd\u003e50\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of configurable connections per PC station\u003c\/dt\u003e\n\u003cdd\u003e207\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of DP slaves on DP master usable\u003c\/dt\u003e\n\u003cdd\u003e124\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of electrical connections at the 1st interface acc. to PROFIBUS\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of other ports\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of plug-in cards of same design plug-in per PC station\u003c\/dt\u003e\n\u003cdd\u003e4\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of possible connections for open communication by means of SEND\/RECEIVE maximum\u003c\/dt\u003e\n\u003cdd\u003e80\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of possible connections for S7\/PG communication maximum\u003c\/dt\u003e\n\u003cdd\u003e50\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower loss [W] [W]\u003c\/dt\u003e\n\u003cdd\u003e3.5\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct feature device in control circuit\u003c\/dt\u003e\n\u003cdd\u003eyes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct feature device in main circuit\u003c\/dt\u003e\n\u003cdd\u003eno\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct function Port diagnostics\u003c\/dt\u003e\n\u003cdd\u003eyes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct type designation\u003c\/dt\u003e\n\u003cdd\u003eCP 5613 A3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtection class IP\u003c\/dt\u003e\n\u003cdd\u003eIP00\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRelative humidity at 25°C without condensation during operation maximum [%]\u003c\/dt\u003e\n\u003cdd\u003e85\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRelative symmetrical tolerance at DC at 12 V [%]\u003c\/dt\u003e\n\u003cdd\u003e8\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRelative symmetrical tolerance at DC at 3.3 V [%]\u003c\/dt\u003e\n\u003cdd\u003e9\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSecurity information\u003c\/dt\u003e\n\u003cdd\u003eSiemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and\/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens™ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http:\/\/www.siemens.com\/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http:\/\/support.automation.siemens.com. (V3.4)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eService as DP master DPV0\u003c\/dt\u003e\n\u003cdd\u003eyes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eService as DP master DPV1\u003c\/dt\u003e\n\u003cdd\u003eyes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eService as DP master DPV2\u003c\/dt\u003e\n\u003cdd\u003eyes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eService as DP slave DPV0\u003c\/dt\u003e\n\u003cdd\u003eyes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eService as DP slave DPV1\u003c\/dt\u003e\n\u003cdd\u003eyes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSoftware for DP master function required\u003c\/dt\u003e\n\u003cdd\u003eNo\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSoftware for DP slave function required\u003c\/dt\u003e\n\u003cdd\u003eNo\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSoftware for open communication by means of SEND\/RECEIVE required\u003c\/dt\u003e\n\u003cdd\u003eFDL driver included in scope of delivery of the CP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSoftware for S7 communication required\u003c\/dt\u003e\n\u003cdd\u003eYes, HARDNET-PB S7 (S7-5613)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandard for EMC\u003c\/dt\u003e\n\u003cdd\u003e89\/336\/EEC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandard for emitted interference\u003c\/dt\u003e\n\u003cdd\u003eEN 61000-6-3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandard for interference immunity\u003c\/dt\u003e\n\u003cdd\u003eEN 61000-6-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandard for safety from CSA and UL\u003c\/dt\u003e\n\u003cdd\u003eCAN\/CSA C22.2 \u0026amp; UL 60950-1, UL 1950\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply voltage 1 from backplane bus [V]\u003c\/dt\u003e\n\u003cdd\u003e3.3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply voltage 2 from backplane bus [V]\u003c\/dt\u003e\n\u003cdd\u003e12\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTransfer rate at the 1st interface acc. to PROFIBUS maximum [Mbit\/s]\u003c\/dt\u003e\n\u003cdd\u003e12\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTransfer rate at the 1st interface acc. to PROFIBUS minimum [kbit\/s]\u003c\/dt\u003e\n\u003cdd\u003e9.6\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eType of electrical connection at the 1st interface acc. to PROFIBUS\u003c\/dt\u003e\n\u003cdd\u003e9-pin Sub-D socket (RS 485)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eType of voltage of the supply voltage\u003c\/dt\u003e\n\u003cdd\u003eDC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth [mm]\u003c\/dt\u003e\n\u003cdd\u003e18\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eDelivery Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eExport Control Regulations\u003c\/dt\u003e\n\u003cdd\u003eAL : N \/ ECCN : N\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDelivery Time\u003c\/dt\u003e\n\u003cdd\u003e1 Day\/Days\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNet Weight (lb)\u003c\/dt\u003e\n\u003cdd\u003e0,961 lb\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Dimensions (W x L x H)\u003c\/dt\u003e\n\u003cdd\u003eNot available\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePackaging Dimension\u003c\/dt\u003e\n\u003cdd\u003e0,039 x 0,039 x 0,039\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePackage size unit of measure\u003c\/dt\u003e\n\u003cdd\u003ein\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eQuantity Unit\u003c\/dt\u003e\n\u003cdd\u003e1 Piece\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePackaging Quantity\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eAdditional Product Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEAN\u003c\/dt\u003e\n\u003cdd\u003e4019169252485\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUPC\u003c\/dt\u003e\n\u003cdd\u003e887621498320\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCommodity Code\u003c\/dt\u003e\n\u003cdd\u003e85176200\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLKZ_FDB\/ CatalogID\u003c\/dt\u003e\n\u003cdd\u003eIK\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Group\u003c\/dt\u003e\n\u003cdd\u003e2445\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCountry of origin\u003c\/dt\u003e\n\u003cdd\u003eGermany\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRoHS Compliance\u003c\/dt\u003e\n\u003cdd\u003eGiven\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReturnable\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eObligation Category for taking back electrical and electronic equipment after use\u003c\/dt\u003e\n\u003cdd\u003eNo obligation to take back electrical and electronic equipment after use\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49110125248797,"sku":"DA-503354","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/siemens-6gk1561-3aa02-dropship-automation_13b9f2af.webp?v=1754350886","url":"https:\/\/dropshipautomation.com\/products\/siemens-6gk1561-3aa02-1","provider":"Dropship Automation","version":"1.0","type":"link"}