{"product_id":"schneider-electric-zbrn2","title":"SCHNEIDER-ELECTRIC ZBRN2","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003eZBRN2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUNSPSC\u003c\/dt\u003e\n\u003cdd\u003e39122216\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTariff Code\u003c\/dt\u003e\n\u003cdd\u003e8517620090\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCountry of Origin\u003c\/dt\u003e\n\u003cdd\u003eID\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironment\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Certifications\u003c\/dt\u003e\n\u003cdd\u003eGOST || CE || UL || C-tick || CSA || CCC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\u003c\/dt\u003e\n\u003cdd\u003eCSA C22.2 No 14 || EN 62311 || EN\/IEC 61131-2 || ETSI EN 300 440-2 || ETSI EN 300 328 || EN\/IEC 60950-1 || UL 508\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStorage Altitude\u003c\/dt\u003e\n\u003cdd\u003e0-3000 m\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectromagnetic Compatibility\u003c\/dt\u003e\n\u003cdd\u003e1.2\/50 µs shock waves immunity test - test level: 1 kV (differential mode) conforming to IEC 61000-4-5 || 1.2\/50 µs shock waves immunity test - test level: 2 kV (common mode) conforming to IEC 61000-4-5 || immunity to microbreaks and voltage drops - test level: 10 ms conforming to IEC 61000-4-11\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShock Resistance\u003c\/dt\u003e\n\u003cdd\u003e10 gn 16 ms) 6000 shocks IEC 60068-2-27\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVibration Resistance\u003c\/dt\u003e\n\u003cdd\u003e+\/- 3.5 mm 5-14 Hz) IEC 60068-2-6 || 1 gn 5-150 Hz) on panel mounting IEC 60068-2-6 || 2 gn 8-150 Hz) on DIN rail IEC 60068-2-6\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIp Degree Of Protection\u003c\/dt\u003e\n\u003cdd\u003eIP20 IEC 60529 casing) || IP20 terminals)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePollution Degree\u003c\/dt\u003e\n\u003cdd\u003e2 IEC 60664-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDirectives\u003c\/dt\u003e\n\u003cdd\u003e2006\/95\/EC - low voltage directive || 2004\/108\/EC - electromagnetic compatibility || 1999\/5\/EC - R\u0026amp;TTE directive\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature For Storage\u003c\/dt\u003e\n\u003cdd\u003e-40-70°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRelative Humidity\u003c\/dt\u003e\n\u003cdd\u003e90-90 % -25-55°C, without condensation ETSI EN 300 440-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRadio Agreement\u003c\/dt\u003e\n\u003cdd\u003eANATEL, type III ETSI EN 301 489-3 || FCC, category 2 ETSI EN 300 440-1 || ICASA || RSS, category 1 ETSI EN 300 440-1 || SRRC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating Altitude\u003c\/dt\u003e\n\u003cdd\u003e0...6561.68 ft (0...2000 m)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDielectric Strength\u003c\/dt\u003e\n\u003cdd\u003e3000 V between input and output AC || 4250 V between input and output DC || 1500 V between input and ground AC || 2150 V between input and ground DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eComplementary\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectrical Connection\u003c\/dt\u003e\n\u003cdd\u003e1 conductor cable 0.2-4 mm² - AWG 24...AWG 12 - solid - without cable end IEC 60947-1 || 2 conductors cable 0.2-1.5 mm² - AWG 24...AWG 16 - solid - without cable end IEC 60947-1 || 1 conductor cable 0.2-0.75 mm² - AWG 24...AWG 14 - flexible - with cable end IEC 60947-1 || 2 conductors cable 0.2-2.5 mm² - AWG 24...AWG 18 - flexible - with cable end IEC 60947-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Us] Rated Supply Voltage\u003c\/dt\u003e\n\u003cdd\u003e24...240 V AC\/DC 50\/60 Hz - 10...10 %\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e90 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-Circuit Protection\u003c\/dt\u003e\n\u003cdd\u003e16 A GB2 circuit breaker\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/dt\u003e\n\u003cdd\u003e4 kV\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIntegrated Connection Type\u003c\/dt\u003e\n\u003cdd\u003e1 isolated serial link 2 x RJ45 in parallel Modbus Serial line slave Modbus slave RTU asynchronous in baseband RS485, half duplex, 1.2...115.2 kbauds, 2 twisted shielded pairs\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStatus Led\u003c\/dt\u003e\n\u003cdd\u003e1 LED Green power ON || 1 LED Yellow communication network || 5 LEDs Red function mode || 1 LED green and yellow reception signal\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eChannels Utilisation\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt;= 60 devices\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eImmunity To Microbreaks\u003c\/dt\u003e\n\u003cdd\u003e10 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResponse Time\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt; 30 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eData Format\u003c\/dt\u003e\n\u003cdd\u003e7 or 8 bits, 1 or 2 stop bits\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating Position\u003c\/dt\u003e\n\u003cdd\u003eany position\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAntenna Gain\u003c\/dt\u003e\n\u003cdd\u003e0 dBi\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNet Weight\u003c\/dt\u003e\n\u003cdd\u003e0.27 kg\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTopology\u003c\/dt\u003e\n\u003cdd\u003edevices linked by daisy-chaining or tap junctions\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSurge Withstand\u003c\/dt\u003e\n\u003cdd\u003e1 kV differential mode IEC 61000-4-5 || 2 kV common mode IEC 61000-4-5\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Short-Duration Power Frequency Withstand Voltage\u003c\/dt\u003e\n\u003cdd\u003e1.5 kV 50 Hz EN\/IEC 60947-5-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Sensing Distance\u003c\/dt\u003e\n\u003cdd\u003e100 m in free field || 250 m if a relay antenna is located between the transmitter and Harmony Hub || 60 m if an external antenna is connected to Harmony Hub || 25 m with Harmony Hub installed in a metal housing or in a closed metal enclosure\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eBreaking Capacity\u003c\/dt\u003e\n\u003cdd\u003e15 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting Support\u003c\/dt\u003e\n\u003cdd\u003e35 mm symmetrical DIN rail conforming to EN\/IEC 60715 || mounting plate\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHousing Material\u003c\/dt\u003e\n\u003cdd\u003eself-extinguishing plastic\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eBreaking Capacity\u003c\/dt\u003e\n\u003cdd\u003e750 VA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eControl Circuit Frequency\u003c\/dt\u003e\n\u003cdd\u003e50...60 Hz +\/- 10 %\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e122 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e60 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTightening Torque\u003c\/dt\u003e\n\u003cdd\u003e0.35-0.4 N.m EN\/IEC 60947-1 || 3.09-3.54 lbf.in EN\/IEC 60947-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Power Consumption In W\u003c\/dt\u003e\n\u003cdd\u003e4 W AC\/DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eParity\u003c\/dt\u003e\n\u003cdd\u003eno || even || odd\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eData Storage Equipment\u003c\/dt\u003e\n\u003cdd\u003eSD card\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eOffer Sustainability\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRohs Exemption Information\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMercury Free\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEnvironmental Disclosure\u003c\/dt\u003e\n\u003cdd\u003eENVPEP101106EN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSustainable Offer Status\u003c\/dt\u003e\n\u003cdd\u003eGreen Premium product\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReach Regulation\u003c\/dt\u003e\n\u003cdd\u003eReference contains Substances of Very High Concern above the threshold\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCalifornia Proposition 65\u003c\/dt\u003e\n\u003cdd\u003eWARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWeee\u003c\/dt\u003e\n\u003cdd\u003eThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eChina Rohs Regulation\u003c\/dt\u003e\n\u003cdd\u003eX\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCircularity Profile\u003c\/dt\u003e\n\u003cdd\u003eENVEOLI1103010EN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEu Rohs Directive\u003c\/dt\u003e\n\u003cdd\u003ePro-active compliance (Product out of EU RoHS legal scope)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAntenna Type\u003c\/dt\u003e\n\u003cdd\u003eintegrated\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRange Of Product\u003c\/dt\u003e\n\u003cdd\u003eHarmony\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Or Component Type\u003c\/dt\u003e\n\u003cdd\u003eHarmony Hub wireless\/Serial Line gateway\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCommunication Port Protocol\u003c\/dt\u003e\n\u003cdd\u003eModbus client application\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Specific Application\u003c\/dt\u003e\n\u003cdd\u003eWireless Schneider Electric devices ecosystem\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFunction Of Module\u003c\/dt\u003e\n\u003cdd\u003eZigbee green power concentrator\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice Short Name\u003c\/dt\u003e\n\u003cdd\u003eZBRN2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTransmission Frequency\u003c\/dt\u003e\n\u003cdd\u003e2405-2480 MHz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49149427450141,"sku":"DA-650967","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/dropship-automation_2d256312-10bc-4c7e-841f-cc35d9e96c6b.webp?v=1732784258","url":"https:\/\/dropshipautomation.com\/products\/schneider-electric-zbrn2","provider":"Dropship Automation","version":"1.0","type":"link"}