{"product_id":"schneider-electric-tm221m16rg","title":"SCHNEIDER-ELECTRIC TM221M16RG","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003eTM221M16RG\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUNSPSC\u003c\/dt\u003e\n\u003cdd\u003e32151705\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTariff Code\u003c\/dt\u003e\n\u003cdd\u003e8537109160\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCountry of Origin\u003c\/dt\u003e\n\u003cdd\u003eCN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eComplementary\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDiscrete Input Logic\u003c\/dt\u003e\n\u003cdd\u003esink or source (positive\/negative)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eData Backed Up\u003c\/dt\u003e\n\u003cdd\u003e256 kB built-in flash memory backup of application and data\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eExct Time For Event Task\u003c\/dt\u003e\n\u003cdd\u003e60 µs response time\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInput Impedance\u003c\/dt\u003e\n\u003cdd\u003e100 kOhm analog input || 3.4 kOhm input || 4.9 kOhm fast input\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectrical Connection\u003c\/dt\u003e\n\u003cdd\u003eterminal block, 3 for connecting the 24 V DC power supply || connector, 4 for analogue inputs || mini B USB 2.0 connector for a programming terminal || removable spring terminal block, 10 for inputs || removable spring terminal block, 11 for outputs\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Cable Distance Between Devices\u003c\/dt\u003e\n\u003cdd\u003eshielded cable \u0026lt;10 m fast input || unshielded cable \u0026lt;30 m output || unshielded cable \u0026lt;30 m digital input || unshielded cable \u0026lt;1 m analog input\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e90 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDiscrete Input Voltage\u003c\/dt\u003e\n\u003cdd\u003e24 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Power Consumption In W\u003c\/dt\u003e\n\u003cdd\u003e22.5 W 24 V with max number of I\/O expansion module) || 3.6 W 24 V without I\/O expansion module)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInrush Current\u003c\/dt\u003e\n\u003cdd\u003e35 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDiscrete Input Voltage Type\u003c\/dt\u003e\n\u003cdd\u003eDC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCommunication Service\u003c\/dt\u003e\n\u003cdd\u003eModbus slave || Modbus master\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Current Per Output Common\u003c\/dt\u003e\n\u003cdd\u003e7 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTransmission Rate\u003c\/dt\u003e\n\u003cdd\u003e1.2...115.2 kbit\/s (115.2 kbit\/s by default) 15-15 m RS485 || 1.2...115.2 kbit\/s (115.2 kbit\/s by default) 3-3 m RS232 || 480 Mbit\/s USB\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eClock Drift\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt;= 30 s\/month 25-25°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eBattery Type\u003c\/dt\u003e\n\u003cdd\u003eBR2032 or CR2032X lithium non-rechargeable\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCommunication Port Protocol\u003c\/dt\u003e\n\u003cdd\u003eUSB port USB - SoMachine-Network || non isolated serial link Modbus master\/slave - RTU\/ASCII or SoMachine-Network\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtection Type\u003c\/dt\u003e\n\u003cdd\u003ewithout protection 5 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMarking\u003c\/dt\u003e\n\u003cdd\u003eCE\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eBackup Time\u003c\/dt\u003e\n\u003cdd\u003e1 year 25°C by interruption of power supply)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDiscrete I\/O Number\u003c\/dt\u003e\n\u003cdd\u003e16\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReset Time\u003c\/dt\u003e\n\u003cdd\u003e1 s\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRegulation Loop\u003c\/dt\u003e\n\u003cdd\u003eadjustable PID regulator up to 14 simultaneous loops\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Number Of I\/O Expansion Module\u003c\/dt\u003e\n\u003cdd\u003e7 (local I\/O-Architecture) || 14 (remote I\/O-Architecture)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower Supply Output Current\u003c\/dt\u003e\n\u003cdd\u003e0.52-0.52 A 5 V expansion bus || 0.46-0.46 A 24 V expansion bus\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNet Weight\u003c\/dt\u003e\n\u003cdd\u003e0.264 kg\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eApplication Structure\u003c\/dt\u003e\n\u003cdd\u003e8 interrupt tasks || 1 cyclic auxiliary task || 1 configurable freewheeling\/cyclic master task\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage State 0 Guaranteed\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt;= 5 V input\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConfigurable Filtering Time\u003c\/dt\u003e\n\u003cdd\u003e0 ms input || 3 ms input || 12 ms input\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOutput Voltage Limits\u003c\/dt\u003e\n\u003cdd\u003e125 V DC || 277 V AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Size Of Object Areas\u003c\/dt\u003e\n\u003cdd\u003e8000 %MW memory words || 255 %TM timers || 255 %C counters || 512 %KW constant words || 512 %M memory bits\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMemory Capacity\u003c\/dt\u003e\n\u003cdd\u003e256 kB user application and data RAM 10000 instructions || 256 kB internal variables RAM\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConversion Time\u003c\/dt\u003e\n\u003cdd\u003e1 ms per channel + 1 controller cycle time analog input\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage State 1 Guaranteed\u003c\/dt\u003e\n\u003cdd\u003e\u0026gt;= 15 V input\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eControl Signal Type\u003c\/dt\u003e\n\u003cdd\u003eA\/B || pulse\/direction || single phase\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply Voltage Limits\u003c\/dt\u003e\n\u003cdd\u003e20.4-28.8 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIntegrated Connection Type\u003c\/dt\u003e\n\u003cdd\u003eUSB port mini B USB 2.0 || non isolated serial link serial 1 RJ45 RS485 || non isolated serial link serial 2 RJ45 RS232\/RS485\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eExecution Time Per Instruction\u003c\/dt\u003e\n\u003cdd\u003e0.2 µs Boolean\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMechanical Durability\u003c\/dt\u003e\n\u003cdd\u003e20000000 cycles relay output\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectrical Durability\u003c\/dt\u003e\n\u003cdd\u003e100000 cycles AC-12, 120 V, 240 VA, resistive || 100000 cycles AC-12, 240 V, 480 VA, resistive || 300000 cycles AC-12, 120 V, 80 VA, resistive || 300000 cycles AC-12, 240 V, 160 VA, resistive || 100000 cycles AC-15, cos phi = 0.35 , 120 V, 60 VA, inductive || 100000 cycles AC-15, cos phi = 0.35 , 240 V, 120 VA, inductive || 300000 cycles AC-15, cos phi = 0.35 , 120 V, 18 VA, inductive || 300000 cycles AC-15, cos phi = 0.35 , 240 V, 36 VA, inductive || 100000 cycles AC-14, cos phi = 0.7 , 120 V, 120 VA, inductive || 100000 cycles AC-14, cos phi = 0.7 , 240 V, 240 VA, inductive || 300000 cycles AC-14, cos phi = 0.7 , 120 V, 36 VA, inductive || 300000 cycles AC-14, cos phi = 0.7 , 240 V, 72 VA, inductive || 100000 cycles DC-12, 24 V, 48 W, resistive || 300000 cycles DC-12, 24 V, 16 W, resistive || 100000 cycles DC-13, 24 V, 24 W, inductive (L\/R = 7 ms) || 300000 cycles DC-13, 24 V, 7.2 W, inductive (L\/R = 7 ms)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAbsolute Accuracy Error\u003c\/dt\u003e\n\u003cdd\u003e+\/- 1 % of full scale analog input\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting Support\u003c\/dt\u003e\n\u003cdd\u003etop hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || plate or panel with fixing kit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLocal Signalling\u003c\/dt\u003e\n\u003cdd\u003efor PWR 1 LED (green) || for RUN 1 LED (green) || for module error (ERR) 1 LED (red) || for SD card access (SD) 1 LED (green) || for BAT 1 LED (red) || for SL1 1 LED (green) || for SL2 1 LED (green) || for I\/O state 1 LED per channel (green)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResponse Time\u003c\/dt\u003e\n\u003cdd\u003e35 µs turn-off, I2...I5 input || 10 ms turn-on output || 10 ms turn-off output || 5 µs turn-on, I0, I1, I6, I7 fast input || 35 µs turn-on, other terminals input || 5 µs turn-off, I0, I1, I6, I7 fast input || 100 µs turn-off, other terminals input\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDiscrete Input Current\u003c\/dt\u003e\n\u003cdd\u003e7 mA discrete input || 5 mA fast input\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eExecution Time For 1 Kinstruction\u003c\/dt\u003e\n\u003cdd\u003e0.3 ms event and periodic task || 0.7 ms other instruction\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAnalogue Input Resolution\u003c\/dt\u003e\n\u003cdd\u003e10 bits\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRealtime Clock\u003c\/dt\u003e\n\u003cdd\u003ewith\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLsb Value\u003c\/dt\u003e\n\u003cdd\u003e10 mV\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e70 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e70 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMinimum Load\u003c\/dt\u003e\n\u003cdd\u003e1 mA 5 V DC relay output\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eData Storage Equipment\u003c\/dt\u003e\n\u003cdd\u003e2 GB SD card optional)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInsulation\u003c\/dt\u003e\n\u003cdd\u003ebetween input and internal logic 500 V AC || between fast input and internal logic 500 V AC || non-insulated between inputs || between output and internal logic 500 V AC || between output groups 500 V AC || non-insulated between analogue input and internal logic || non-insulated between analogue inputs\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply\u003c\/dt\u003e\n\u003cdd\u003eserial 1)serial link supply 5 V, \u0026lt;200 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCounting Input Number\u003c\/dt\u003e\n\u003cdd\u003e4 fast input (HSC mode) 100 kHz 32 bits\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePermitted Overload On Inputs\u003c\/dt\u003e\n\u003cdd\u003e+\/- 30 V DC 5 min maximum)analog input || +\/- 13 V DC permanent)analog input\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching Frequency\u003c\/dt\u003e\n\u003cdd\u003e20 switching operations\/minute with maximum load\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironment\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Certifications\u003c\/dt\u003e\n\u003cdd\u003eRCM || LR || EAC || cULus || DNV-GL || ABS || CSA || CE || UKCA || cULus HazLoc\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResistance To Conducted Disturbances\u003c\/dt\u003e\n\u003cdd\u003e10 V 0.15...80 MHz IEC 61000-4-6 || 3 V 0.1...80 MHz Marine specification (LR, ABS, DNV, GL) || 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResistance To Electromagnetic Fields\u003c\/dt\u003e\n\u003cdd\u003e10 V\/m 80 MHz...1 GHz IEC 61000-4-3 || 3 V\/m 1.4 GHz...2 GHz IEC 61000-4-3 || 1 V\/m 2...2.7 GHz IEC 61000-4-3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\u003c\/dt\u003e\n\u003cdd\u003eIEC 61131-2 || UL 508 || CAN\/CSA C22.2 No. 213 || IACS E10 || ANSI\/ISA 12-12-01\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eImmunity To Microbreaks\u003c\/dt\u003e\n\u003cdd\u003e10 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStorage Altitude\u003c\/dt\u003e\n\u003cdd\u003e0-3000 m\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePollution Degree\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt;= 2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature For Operation\u003c\/dt\u003e\n\u003cdd\u003e-10-55°C horizontal installation) || -10-35°C vertical installation)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShock Resistance\u003c\/dt\u003e\n\u003cdd\u003e98 m\/s² 11 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResistance To Magnetic Fields\u003c\/dt\u003e\n\u003cdd\u003e30 A\/m 50\/60 Hz IEC 61000-4-8\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVibration Resistance\u003c\/dt\u003e\n\u003cdd\u003e3.5 mm 5-8.4 Hz symmetrical rail || 3.5 mm 5-8.4 Hz panel mounting || 1 gn 8.4-150 Hz symmetrical rail || 1 gn 8.4-150 Hz panel mounting\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature For Storage\u003c\/dt\u003e\n\u003cdd\u003e-25-70°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEnvironmental Characteristic\u003c\/dt\u003e\n\u003cdd\u003eordinary and hazardous location\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRelative Humidity\u003c\/dt\u003e\n\u003cdd\u003e10-95 %, without condensation in operation) || 10-95 %, without condensation in storage)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIp Degree Of Protection\u003c\/dt\u003e\n\u003cdd\u003eIP20 with protective cover in place\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResistance To Electrostatic Discharge\u003c\/dt\u003e\n\u003cdd\u003e8 kV in air IEC 61000-4-2 || 4 kV on contact IEC 61000-4-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSurge Withstand\u003c\/dt\u003e\n\u003cdd\u003e2 kV power lines (AC) common mode IEC 61000-4-5 || 2 kV relay output common mode IEC 61000-4-5 || 1 kV I\/O common mode IEC 61000-4-5 || 1 kV shielded cable common mode IEC 61000-4-5 || 0.5 kV power lines (DC) differential mode IEC 61000-4-5 || 1 kV power lines (AC) differential mode IEC 61000-4-5 || 1 kV relay output differential mode IEC 61000-4-5 || 0.5 kV power lines (DC) common mode IEC 61000-4-5\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResistance To Fast Transients\u003c\/dt\u003e\n\u003cdd\u003e2 kV IEC 61000-4-4 power lines) || 2 kV IEC 61000-4-4 relay output) || 1 kV IEC 61000-4-4 I\/O) || 1 kV IEC 61000-4-4 Ethernet line) || 1 kV IEC 61000-4-4 serial link)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating Altitude\u003c\/dt\u003e\n\u003cdd\u003e0...6561.68 ft (0...2000 m)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectromagnetic Emission\u003c\/dt\u003e\n\u003cdd\u003econducted emissions 79 dBμV\/m QP\/66 dBμV\/m AV power lines (AC))0.15-0.5 MHz IEC 55011 || conducted emissions 73 dBμV\/m QP\/60 dBμV\/m AV power lines (AC))0.5-300 MHz IEC 55011 || conducted emissions 120...69 dBµV\/m QP power lines)10-150 kHz IEC 55011 || conducted emissions 63 dBμV\/m QP power lines)1.5-30 MHz IEC 55011 || radiated emissions 40 dBμV\/m QP class A 10 m)30-230 MHz IEC 55011 || conducted emissions 79...63 dBμV\/m QP power lines)150-1500 kHz IEC 55011 || radiated emissions 47 dBμV\/m QP class A 10 m)200-1000 MHz IEC 55011\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDiscrete Output Type\u003c\/dt\u003e\n\u003cdd\u003erelay normally open\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRange Of Product\u003c\/dt\u003e\n\u003cdd\u003eModicon M221\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDiscrete Output Number\u003c\/dt\u003e\n\u003cdd\u003e8 relay\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Or Component Type\u003c\/dt\u003e\n\u003cdd\u003elogic controller\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDiscrete Output Current\u003c\/dt\u003e\n\u003cdd\u003e2 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDiscrete Output Voltage\u003c\/dt\u003e\n\u003cdd\u003e5...125 V DC || 5...250 V AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAnalogue Input Number\u003c\/dt\u003e\n\u003cdd\u003e2 0...10 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Us] Rated Supply Voltage\u003c\/dt\u003e\n\u003cdd\u003e24 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDiscrete Input Number\u003c\/dt\u003e\n\u003cdd\u003e8 , discrete input IEC 61131-2 Type 1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eOffer Sustainability\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRohs Exemption Information\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMercury Free\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEnvironmental Disclosure\u003c\/dt\u003e\n\u003cdd\u003eENVPEP1403012EN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSustainable Offer Status\u003c\/dt\u003e\n\u003cdd\u003eGreen Premium product\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePvc Free\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReach Regulation\u003c\/dt\u003e\n\u003cdd\u003eReference contains Substances of Very High Concern above the threshold\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCalifornia Proposition 65\u003c\/dt\u003e\n\u003cdd\u003eWARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWeee\u003c\/dt\u003e\n\u003cdd\u003eThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eChina Rohs Regulation\u003c\/dt\u003e\n\u003cdd\u003eX\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCircularity Profile\u003c\/dt\u003e\n\u003cdd\u003eENVEOLI1403012EN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEu Rohs Directive\u003c\/dt\u003e\n\u003cdd\u003ePro-active compliance (Product out of EU RoHS legal scope)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49123831742749,"sku":"DA-566356","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/dropship-automation_eb0edc5d-8129-4e59-8e94-e2dd2448d40e.webp?v=1732003531","url":"https:\/\/dropshipautomation.com\/products\/schneider-electric-tm221m16rg","provider":"Dropship Automation","version":"1.0","type":"link"}