{"product_id":"schneider-electric-metsepm5110","title":"SCHNEIDER-ELECTRIC METSEPM5110","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003eMETSEPM5110\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUNSPSC\u003c\/dt\u003e\n\u003cdd\u003e39121106\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTariff Code\u003c\/dt\u003e\n\u003cdd\u003e9030390100\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCountry of Origin\u003c\/dt\u003e\n\u003cdd\u003eIN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironment\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature For Operation\u003c\/dt\u003e\n\u003cdd\u003e-25-70 °C meter || -20-70 °C display || -25--20 °C with reduced performance) display\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectromagnetic Compatibility\u003c\/dt\u003e\n\u003cdd\u003evoltage dips and interruptions immunity test class A conforming to IEC 61000-4-11 || limits for harmonic current emissions class A conforming to IEC 61000-3-2 || electrostatic discharge level 4 conforming to IEC 61000-4-2 || conducted RF disturbances level 3 conforming to IEC 61000-4-6 || magnetic field at power frequency level 4 conforming to IEC 61000-4-8 || conducted and radiated emissions - test level: 150 kHz...80 MHz class B conforming to EN 55022 || immunity to conducted disturbances - test level: 150 kHz...80 MHz conforming to IEC 61000-4-6 || electrical fast transient\/burst immunity test conforming to IEC 61000-4-4 || radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 || surge immunity test class B conforming to IEC 61000-4-5 || voltage dips and interruptions immunity test conforming to IEC 61000-4-11\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePollution Degree\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature For Storage\u003c\/dt\u003e\n\u003cdd\u003e-40-85 °C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRelative Humidity\u003c\/dt\u003e\n\u003cdd\u003e5-95 % 50-50 °C non-condensing\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIp Degree Of Protection\u003c\/dt\u003e\n\u003cdd\u003edisplay IP54 IEC 60529 || rear IP30 IEC 60529\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating Altitude\u003c\/dt\u003e\n\u003cdd\u003e6561.68 ft (2000 m) CAT III\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eComplementary\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNetwork Frequency\u003c\/dt\u003e\n\u003cdd\u003e50 Hz || 60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCommunication Port Support\u003c\/dt\u003e\n\u003cdd\u003eRS485\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower Quality Analysis\u003c\/dt\u003e\n\u003cdd\u003eup to the 15th harmonic\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e96 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMeasurement Voltage\u003c\/dt\u003e\n\u003cdd\u003e35-760 V AC 45...65 Hz between phases || 20-440 V AC 45...65 Hz between phase and neutral\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSampling Rate\u003c\/dt\u003e\n\u003cdd\u003e64 samples\/cycle\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber Of Outputs\u003c\/dt\u003e\n\u003cdd\u003e1 digital\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\u003c\/dt\u003e\n\u003cdd\u003eUL 61010-1 || EN 50470-3 || EN 50470-1 || IEC 62053-22:2020 || IEC 60529 || IEC 62053-24 || IEC 61557-12:2015 || IEC 62053-23:2020 || IEC 62052-11:2020 || IEC 62052-31:2015\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Certifications\u003c\/dt\u003e\n\u003cdd\u003eCE IEC 61010-1 || cULus UL 61010-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eType Of Measurement\u003c\/dt\u003e\n\u003cdd\u003ecurrent || voltage || frequency || power factor || energy || active and reactive power\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCommunication Port Protocol\u003c\/dt\u003e\n\u003cdd\u003eModbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even\/odd or none - 2 wires 2500 V || JBUS\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFrequency Measurement Range\u003c\/dt\u003e\n\u003cdd\u003e45-65 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRide-Through Time\u003c\/dt\u003e\n\u003cdd\u003e80 ms 120 V AC typical || 100 ms 230 V AC typical || 100 ms 415 V AC typical || 50 ms 125 V DC typical\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDisplay Resolution\u003c\/dt\u003e\n\u003cdd\u003e128 x 128 pixels\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber Of Inputs\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNet Weight\u003c\/dt\u003e\n\u003cdd\u003e380 g\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e72 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMeasurement Current\u003c\/dt\u003e\n\u003cdd\u003e50-8500 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnections - Terminals\u003c\/dt\u003e\n\u003cdd\u003evoltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || input\/output circuit screw terminal block6 || RS485 link screw terminal block4\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Us] Rated Supply Voltage\u003c\/dt\u003e\n\u003cdd\u003e90...450 V AC 45...65 Hz || 100...300 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting Mode\u003c\/dt\u003e\n\u003cdd\u003eflush-mounted\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMeasurement Accuracy\u003c\/dt\u003e\n\u003cdd\u003eactive energy +\/- 0.5 % || reactive energy +\/- 2 % || active power +\/- 0.5 % || apparent power +\/- 0.5 % || frequency +\/- 0.05 % || power factor +\/- 0.5 || current +\/- 0.5 % || voltage +\/- 0.5 % || apparent energy +\/- 0.5 % || reactive power +\/- 2 %\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting Support\u003c\/dt\u003e\n\u003cdd\u003eframework\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePoles Description\u003c\/dt\u003e\n\u003cdd\u003e1P + N || 3P + N || 3P\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eData Recording\u003c\/dt\u003e\n\u003cdd\u003etime stamping || min\/max of instantaneous values\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLine Rated Current\u003c\/dt\u003e\n\u003cdd\u003e1 A || 5 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAnalogue Input Type\u003c\/dt\u003e\n\u003cdd\u003evoltage (impedance 5 MOhm) || current (impedance \u0026lt;= 0.3 mOhm)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e96 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDisplay Type\u003c\/dt\u003e\n\u003cdd\u003emonochrome graphic LCD\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice Application\u003c\/dt\u003e\n\u003cdd\u003epower monitoring\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAccuracy Class\u003c\/dt\u003e\n\u003cdd\u003eclass 0.5S active energy IEC 62053-22\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Power Consumption In Va\u003c\/dt\u003e\n\u003cdd\u003e11 VA 415 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eOffer Sustainability\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRohs Exemption Information\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMercury Free\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEnvironmental Disclosure\u003c\/dt\u003e\n\u003cdd\u003eENVPEP1305025\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSustainable Offer Status\u003c\/dt\u003e\n\u003cdd\u003eGreen Premium product\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReach Regulation\u003c\/dt\u003e\n\u003cdd\u003eReference contains Substances of Very High Concern above the threshold\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCalifornia Proposition 65\u003c\/dt\u003e\n\u003cdd\u003eWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWeee\u003c\/dt\u003e\n\u003cdd\u003eThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eChina Rohs Regulation\u003c\/dt\u003e\n\u003cdd\u003eX\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCircularity Profile\u003c\/dt\u003e\n\u003cdd\u003eENVEOLI1305025\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEu Rohs Directive\u003c\/dt\u003e\n\u003cdd\u003eCompliant with Exemptions\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Or Component Type\u003c\/dt\u003e\n\u003cdd\u003epower meter\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Name\u003c\/dt\u003e\n\u003cdd\u003ePowerLogic PM5000\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRange\u003c\/dt\u003e\n\u003cdd\u003ePowerLogic\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice Short Name\u003c\/dt\u003e\n\u003cdd\u003ePM5110\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49035558584605,"sku":"DA-266405","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/schneider-electric-metsepm5110-dropship-automation.webp?v=1752854404","url":"https:\/\/dropshipautomation.com\/products\/schneider-electric-metsepm5110","provider":"Dropship Automation","version":"1.0","type":"link"}