{"product_id":"schneider-electric-m9f11132","title":"SCHNEIDER-ELECTRIC M9F11132","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003eM9F11132\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUNSPSC\u003c\/dt\u003e\n\u003cdd\u003e39121603\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTariff Code\u003c\/dt\u003e\n\u003cdd\u003e8536200020\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCountry of Origin\u003c\/dt\u003e\n\u003cdd\u003eFR\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eComplementary\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNetwork Frequency\u003c\/dt\u003e\n\u003cdd\u003e50\/60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ics] Rated Service Breaking Capacity\u003c\/dt\u003e\n\u003cdd\u003e7.5 kA 75 % EN\/IEC 60947-2 - 240 V AC 50\/60 Hz || 2.25 kA 75 % EN\/IEC 60947-2 - 415 V AC 50\/60 Hz || 15 kA 100 % EN\/IEC 60947-2 - \u0026lt;= 72 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e81 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eContact Position Indicator\u003c\/dt\u003e\n\u003cdd\u003eyes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEarth-Leakage Protection\u003c\/dt\u003e\n\u003cdd\u003eseparate block\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting Support\u003c\/dt\u003e\n\u003cdd\u003eDIN rail\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e9 Mm Pitches\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLimitation Class\u003c\/dt\u003e\n\u003cdd\u003e3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNet Weight\u003c\/dt\u003e\n\u003cdd\u003e0.12 kg\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWire Stripping Length\u003c\/dt\u003e\n\u003cdd\u003e14 mm for top or bottom connection\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eControl Type\u003c\/dt\u003e\n\u003cdd\u003etoggle\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnections - Terminals\u003c\/dt\u003e\n\u003cdd\u003etunnel type terminal top or bottom) 1.5-35 mm² - rigid || tunnel type terminal top or bottom) 1.5-35 mm² - flexible || tunnel type terminal top or bottom) 1.5-35 mm² - flexible with ferrule\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ui] Rated Insulation Voltage\u003c\/dt\u003e\n\u003cdd\u003e500 V AC 50\/60 Hz EN\/IEC 60947-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting Mode\u003c\/dt\u003e\n\u003cdd\u003eclip-on\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectrical Durability\u003c\/dt\u003e\n\u003cdd\u003e10000 cycles\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMechanical Durability\u003c\/dt\u003e\n\u003cdd\u003e20000 cycles\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLocal Signalling\u003c\/dt\u003e\n\u003cdd\u003eON\/OFF indication\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/dt\u003e\n\u003cdd\u003e6 kVEN\/IEC 60947-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eColor\u003c\/dt\u003e\n\u003cdd\u003eGray\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e18 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProvision For Padlocking\u003c\/dt\u003e\n\u003cdd\u003epadlockable\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e72 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTightening Torque\u003c\/dt\u003e\n\u003cdd\u003e3.5-3.5 N.m top or bottom\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMagnetic Tripping Limit\u003c\/dt\u003e\n\u003cdd\u003e8.5 x In +\/- 20 % AC || 12 x In +\/- 20 % DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ue] Rated Operational Voltage\u003c\/dt\u003e\n\u003cdd\u003e240 V AC 50\/60 Hz between phase and neutral || 415 V AC 50\/60 Hz between phase and neutral || \u0026lt;= 72 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eOffer Sustainability\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRohs Exemption Information\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMercury Free\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEnvironmental Disclosure\u003c\/dt\u003e\n\u003cdd\u003eENVPEP1304004EN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSustainable Offer Status\u003c\/dt\u003e\n\u003cdd\u003eGreen Premium product\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReach Regulation\u003c\/dt\u003e\n\u003cdd\u003eReference contains Substances of Very High Concern above the threshold\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWeee\u003c\/dt\u003e\n\u003cdd\u003eThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eChina Rohs Regulation\u003c\/dt\u003e\n\u003cdd\u003eProduct out of China RoHS scope. Substance declaration for your information.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCircularity Profile\u003c\/dt\u003e\n\u003cdd\u003eN\/A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEu Rohs Directive\u003c\/dt\u003e\n\u003cdd\u003eCompliant with Exemptions\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHalogen Content Performance\u003c\/dt\u003e\n\u003cdd\u003eHalogen free product\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLine Rated Current\u003c\/dt\u003e\n\u003cdd\u003e32 A 50°C EN\/IEC 60947-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurve Code\u003c\/dt\u003e\n\u003cdd\u003eC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber Of Protected Poles\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNetwork Type\u003c\/dt\u003e\n\u003cdd\u003eDC || AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\u003c\/dt\u003e\n\u003cdd\u003eEN\/IEC 60947-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Certifications\u003c\/dt\u003e\n\u003cdd\u003eEAC || KC || CCC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Or Component Type\u003c\/dt\u003e\n\u003cdd\u003eminiature circuit-breaker\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Name\u003c\/dt\u003e\n\u003cdd\u003eMulti9 C60\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUtilisation Category\u003c\/dt\u003e\n\u003cdd\u003ecategory A EN\/IEC 60947-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRange\u003c\/dt\u003e\n\u003cdd\u003eMulti9\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eBreaking Capacity\u003c\/dt\u003e\n\u003cdd\u003e15 kA Icu \u0026lt;= 72 V DC EN\/IEC 60947-2 || 10 kA Icu 240 V AC 50\/60 Hz between phase and neutral EN\/IEC 60947-2 || 3 kA Icu 415 V AC 50\/60 Hz between phase and neutral EN\/IEC 60947-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSuitability For Isolation\u003c\/dt\u003e\n\u003cdd\u003eyes EN\/IEC 60947-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePoles Description\u003c\/dt\u003e\n\u003cdd\u003e1P\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice Application\u003c\/dt\u003e\n\u003cdd\u003edistribution\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice Short Name\u003c\/dt\u003e\n\u003cdd\u003eC60N\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTrip Unit Technology\u003c\/dt\u003e\n\u003cdd\u003ethermal-magnetic\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironment\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature For Operation\u003c\/dt\u003e\n\u003cdd\u003e-30-70°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTropicalisation\u003c\/dt\u003e\n\u003cdd\u003e2 IEC 60068-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIp Degree Of Protection\u003c\/dt\u003e\n\u003cdd\u003eIP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePollution Degree\u003c\/dt\u003e\n\u003cdd\u003e3 EN\/IEC 60947-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature For Storage\u003c\/dt\u003e\n\u003cdd\u003e-40-80°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRelative Humidity\u003c\/dt\u003e\n\u003cdd\u003e95-95 % 55-55°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOvervoltage Category\u003c\/dt\u003e\n\u003cdd\u003eIV\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeat Dissipation\u003c\/dt\u003e\n\u003cdd\u003e3.5-3.5 W 240 V - 32 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49046081962269,"sku":"DA-298593","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/schneider-electric-m9f11132-dropship-automation.webp?v=1752934088","url":"https:\/\/dropshipautomation.com\/products\/schneider-electric-m9f11132","provider":"Dropship Automation","version":"1.0","type":"link"}