{"product_id":"schneider-electric-lv431404","title":"SCHNEIDER-ELECTRIC LV431404","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003eLV431404\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUNSPSC\u003c\/dt\u003e\n\u003cdd\u003e39121601\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCountry of Origin\u003c\/dt\u003e\n\u003cdd\u003ePL\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNetwork Frequency\u003c\/dt\u003e\n\u003cdd\u003e50\/60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLine Rated Current\u003c\/dt\u003e\n\u003cdd\u003e250 A 40°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRange Of Product\u003c\/dt\u003e\n\u003cdd\u003eComPact NSX100...250\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ue] Rated Operational Voltage\u003c\/dt\u003e\n\u003cdd\u003e690 V AC 50\/60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNetwork Type\u003c\/dt\u003e\n\u003cdd\u003eAC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Or Component Type\u003c\/dt\u003e\n\u003cdd\u003ebasic frame\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRange\u003c\/dt\u003e\n\u003cdd\u003eComPact\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eControl Type\u003c\/dt\u003e\n\u003cdd\u003etoggle\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUtilisation Category\u003c\/dt\u003e\n\u003cdd\u003ecategory A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting Mode\u003c\/dt\u003e\n\u003cdd\u003efixed\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eBreaking Capacity\u003c\/dt\u003e\n\u003cdd\u003e85 kA 240 V AC 50\/60 Hz UL 508 || 65 kA 480 V AC 50\/60 Hz UL 508 || 10 kA Icu 660\/690 V AC 50\/60 Hz IEC 60947-2 || 100 kA Icu 220\/240 V AC 50\/60 Hz IEC 60947-2 || 35 kA Icu 525 V AC 50\/60 Hz IEC 60947-2 || 50 kA Icu 500 V AC 50\/60 Hz IEC 60947-2 || 65 kA Icu 440 V AC 50\/60 Hz IEC 60947-2 || 70 kA Icu 380\/415 V AC 50\/60 Hz IEC 60947-2 || 15 kA 600 V AC 50\/60 Hz UL 508\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSuitability For Isolation\u003c\/dt\u003e\n\u003cdd\u003eyes EN\/IEC 60947-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePoles Description\u003c\/dt\u003e\n\u003cdd\u003e3P\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice Application\u003c\/dt\u003e\n\u003cdd\u003edistribution\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice Short Name\u003c\/dt\u003e\n\u003cdd\u003eNSX250H\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCircuit Breaker Name\u003c\/dt\u003e\n\u003cdd\u003eCompact NSX250H\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eContractual warranty\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWarranty\u003c\/dt\u003e\n\u003cdd\u003e18 months\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eComplementary\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ics] Rated Service Breaking Capacity\u003c\/dt\u003e\n\u003cdd\u003e10 kA 660\/690 V AC 50\/60 Hz IEC 60947-2 || 100 kA 220\/240 V AC 50\/60 Hz IEC 60947-2 || 35 kA 525 V AC 50\/60 Hz IEC 60947-2 || 50 kA 500 V AC 50\/60 Hz IEC 60947-2 || 65 kA 440 V AC 50\/60 Hz IEC 60947-2 || 70 kA 380\/415 V AC 50\/60 Hz IEC 60947-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e161 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection Pitch\u003c\/dt\u003e\n\u003cdd\u003e35 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting Support\u003c\/dt\u003e\n\u003cdd\u003ebackplate\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDownside Connection\u003c\/dt\u003e\n\u003cdd\u003efront\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUpside Connection\u003c\/dt\u003e\n\u003cdd\u003efront\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectrical Durability\u003c\/dt\u003e\n\u003cdd\u003e10000 cycles 440 V AC 50\/60 Hz In IEC 60947-2 || 10000 cycles 690 V AC 50\/60 Hz In\/2 IEC 60947-2 || 20000 cycles 440 V AC 50\/60 Hz In\/2 IEC 60947-2 || 5000 cycles 690 V AC 50\/60 Hz In IEC 60947-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ui] Rated Insulation Voltage\u003c\/dt\u003e\n\u003cdd\u003e800 V AC 50\/60 Hz IEC 60947-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMechanical Durability\u003c\/dt\u003e\n\u003cdd\u003e20000 cycles IEC 60947-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtection Type\u003c\/dt\u003e\n\u003cdd\u003ewithout protection\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/dt\u003e\n\u003cdd\u003e8 kVIEC 60947-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e105 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e86 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eOffer Sustainability\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRohs Exemption Information\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMercury Free\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEnvironmental Disclosure\u003c\/dt\u003e\n\u003cdd\u003eENVPEP120606EN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSustainable Offer Status\u003c\/dt\u003e\n\u003cdd\u003eGreen Premium product\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCalifornia Proposition 65\u003c\/dt\u003e\n\u003cdd\u003eWARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWeee\u003c\/dt\u003e\n\u003cdd\u003eThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eChina Rohs Regulation\u003c\/dt\u003e\n\u003cdd\u003eProduct out of China RoHS scope. Substance declaration for your information.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCircularity Profile\u003c\/dt\u003e\n\u003cdd\u003eENVEOLI120604EN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEu Rohs Directive\u003c\/dt\u003e\n\u003cdd\u003eCompliant\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironment\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIk Degree Of Protection\u003c\/dt\u003e\n\u003cdd\u003eIK07 IEC 62262\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature For Operation\u003c\/dt\u003e\n\u003cdd\u003e-25-70°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\u003c\/dt\u003e\n\u003cdd\u003eEN\/IEC 60947-2 || UL 508\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIp Degree Of Protection\u003c\/dt\u003e\n\u003cdd\u003eIP40 conforming to IEC 60529\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePollution Degree\u003c\/dt\u003e\n\u003cdd\u003e3 IEC 60664-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature For Storage\u003c\/dt\u003e\n\u003cdd\u003e-50-85°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49086058266909,"sku":"DA-405082","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/schneider-electric-lv431404-dropship-automation.webp?v=1753895894","url":"https:\/\/dropshipautomation.com\/products\/schneider-electric-lv431404","provider":"Dropship Automation","version":"1.0","type":"link"}