{"product_id":"schneider-electric-lp5k0901bw3","title":"SCHNEIDER-ELECTRIC LP5K0901BW3","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003eLP5K0901BW3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUNSPSC\u003c\/dt\u003e\n\u003cdd\u003e39121529\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTariff Code\u003c\/dt\u003e\n\u003cdd\u003e8536490065\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCountry of Origin\u003c\/dt\u003e\n\u003cdd\u003eFR\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironment\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMechanical Robustness\u003c\/dt\u003e\n\u003cdd\u003eshocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 || shocks contactor opened, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Y axis6 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on X axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis10 Gn for 11 ms IEC 60068-2-27\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature For Operation\u003c\/dt\u003e\n\u003cdd\u003e-25-50°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e58 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNet Weight\u003c\/dt\u003e\n\u003cdd\u003e0.49 kg\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFlame Retardance\u003c\/dt\u003e\n\u003cdd\u003eV1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature For Storage\u003c\/dt\u003e\n\u003cdd\u003e-50-80°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtective Treatment\u003c\/dt\u003e\n\u003cdd\u003eTC IEC 60068 || TC DIN 50016\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIp Degree Of Protection\u003c\/dt\u003e\n\u003cdd\u003eIP20 VDE 0106\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating Altitude\u003c\/dt\u003e\n\u003cdd\u003e6561.68 ft (2000 m) without derating\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e90 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e57 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eContractual warranty\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWarranty\u003c\/dt\u003e\n\u003cdd\u003e18 months\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eOffer Sustainability\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRohs Exemption Information\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMercury Free\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEnvironmental Disclosure\u003c\/dt\u003e\n\u003cdd\u003eENVPEP1503003EN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSustainable Offer Status\u003c\/dt\u003e\n\u003cdd\u003eGreen Premium product\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eToxic Heavy Metal Free\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReach Regulation\u003c\/dt\u003e\n\u003cdd\u003eFree of Substances of Very High Concern above the threshold\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCalifornia Proposition 65\u003c\/dt\u003e\n\u003cdd\u003eWARNING: This product can expose you to chemicals including: Antimony oxide \u0026amp; Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReach Free Of Svhc\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWeee\u003c\/dt\u003e\n\u003cdd\u003eThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eChina Rohs Regulation\u003c\/dt\u003e\n\u003cdd\u003ePro-active China RoHS declaration (out of China RoHS legal scope)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCircularity Profile\u003c\/dt\u003e\n\u003cdd\u003eENVEOLI1503003EN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEu Rohs Directive\u003c\/dt\u003e\n\u003cdd\u003eCompliant\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eComplementary\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMinimum Switching Current\u003c\/dt\u003e\n\u003cdd\u003e5 mA for signalling circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eControl Circuit Voltage Limits\u003c\/dt\u003e\n\u003cdd\u003eoperational: 0.7...1.30 Uc (at \u0026lt;50°C) || drop-out: 0.1...0.7 Uc (at \u0026lt;50°C)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNon Overlap Distance\u003c\/dt\u003e\n\u003cdd\u003e0.5 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHold-In Power Consumption In W\u003c\/dt\u003e\n\u003cdd\u003e1.8-1.8 W 20°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInsulation Resistance\u003c\/dt\u003e\n\u003cdd\u003e\u0026gt; 10 MOhm for signalling circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCoil Technology\u003c\/dt\u003e\n\u003cdd\u003ebuilt-in bidirectional peak limiting diode suppressor\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMinimum Switching Voltage\u003c\/dt\u003e\n\u003cdd\u003e17 V for signalling circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInrush Power In W\u003c\/dt\u003e\n\u003cdd\u003e1.8-1.8 W 20°C)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAuxiliary Contacts Type\u003c\/dt\u003e\n\u003cdd\u003einstantaneous 1 NC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeat Dissipation\u003c\/dt\u003e\n\u003cdd\u003e1.8-1.8 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Certifications\u003c\/dt\u003e\n\u003cdd\u003eCB Scheme || CCC || UL || CSA || EAC || CE || UKCA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInterlocking Type\u003c\/dt\u003e\n\u003cdd\u003emechanical\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Uc] Control Circuit Voltage\u003c\/dt\u003e\n\u003cdd\u003e24 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ue] Rated Operational Voltage\u003c\/dt\u003e\n\u003cdd\u003epower circuit 690 V AC 50\/60 Hz || signalling circuit \u0026lt;= 690 V AC 50\/60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAverage Impedance\u003c\/dt\u003e\n\u003cdd\u003e3 mOhm - Ith 20 A 50 Hz for power circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAuxiliary Contact Composition\u003c\/dt\u003e\n\u003cdd\u003e1 NC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ith] Conventional Free Air Thermal Current\u003c\/dt\u003e\n\u003cdd\u003e20 A (at 50°C) for power circuit || 10 A (at 50°C) for signalling circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\u003c\/dt\u003e\n\u003cdd\u003eEN\/IEC 60947-4-1 || GB\/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting Support\u003c\/dt\u003e\n\u003cdd\u003erail || plate\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eControl Circuit Type\u003c\/dt\u003e\n\u003cdd\u003eDC low consumption\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSafety Reliability Level\u003c\/dt\u003e\n\u003cdd\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eContactor Application\u003c\/dt\u003e\n\u003cdd\u003emotor control || resistive load\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Breaking Capacity\u003c\/dt\u003e\n\u003cdd\u003e110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Or Component Type\u003c\/dt\u003e\n\u003cdd\u003ereversing contactor\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIrms Rated Making Capacity\u003c\/dt\u003e\n\u003cdd\u003e110 A AC for power circuit conforming to NF C 63-110 || 110 A AC for power circuit conforming to IEC 60947 || 110 A AC for signalling circuit conforming to IEC 60947\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Name\u003c\/dt\u003e\n\u003cdd\u003eTeSys K\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssociated Fuse Rating\u003c\/dt\u003e\n\u003cdd\u003e25 A gG at \u0026lt;= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for signalling circuit conforming to IEC 60947 || 10 A gG for signalling circuit conforming to VDE 0660\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/dt\u003e\n\u003cdd\u003e8 kV\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnections - Terminals\u003c\/dt\u003e\n\u003cdd\u003escrew clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRange\u003c\/dt\u003e\n\u003cdd\u003eTeSys\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePole Contact Composition\u003c\/dt\u003e\n\u003cdd\u003e3 NO\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice Presentation\u003c\/dt\u003e\n\u003cdd\u003epreassembled with reversing power busbar\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUtilisation Category\u003c\/dt\u003e\n\u003cdd\u003eAC-3 || AC-1 || AC-4 || AC-3e\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ie] Rated Operational Current\u003c\/dt\u003e\n\u003cdd\u003e20 A (at \u0026lt;50°C) at \u0026lt;= 440 V AC AC-1 for power circuit || 16 A (at \u0026lt;70°C) at 690 V AC AC-1 for power circuit || 9 A at \u0026lt;= 440 V AC AC-3 for power circuit || 9 A at \u0026lt;= 440 V AC AC-3e for power circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Operating Rate\u003c\/dt\u003e\n\u003cdd\u003e3600 cyc\/h\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectrical Durability\u003c\/dt\u003e\n\u003cdd\u003e1.3 Mcycles 9 A AC-3 \u0026lt;= 440 V || 1.3 Mcycles 9 A AC-3e \u0026lt;= 440 V || 0.16 Mcycles 20 A AC-1 \u0026lt;= 690 V || 0.02 Mcycles 54 A AC-4 \u0026lt;= 440 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMechanical Durability\u003c\/dt\u003e\n\u003cdd\u003e5 Mcycles\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePoles Description\u003c\/dt\u003e\n\u003cdd\u003e3P\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating Time\u003c\/dt\u003e\n\u003cdd\u003e10...20 ms coil de-energisation and NO opening || 30...40 ms coil energisation and NO closing\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTightening Torque\u003c\/dt\u003e\n\u003cdd\u003e0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOvervoltage Category\u003c\/dt\u003e\n\u003cdd\u003eIII\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMotor Power Kw\u003c\/dt\u003e\n\u003cdd\u003e2.2 kW 220...230 V AC 50\/60 Hz || 4 kW 380...415 V AC 50\/60 Hz || 4 kW 440 V AC 50\/60 Hz || 4 kW 480 V AC 50\/60 Hz || 4 kW 500...600 V AC 50\/60 Hz || 4 kW 660...690 V AC 50\/60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ui] Rated Insulation Voltage\u003c\/dt\u003e\n\u003cdd\u003epower circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-5-1 || signalling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || signalling circuit 600 V CSA C22.2 No 14\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice Application\u003c\/dt\u003e\n\u003cdd\u003econtrol\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice Short Name\u003c\/dt\u003e\n\u003cdd\u003eLP5K\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Icw] Rated Short-Time Withstand Current\u003c\/dt\u003e\n\u003cdd\u003e90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 80 A - 1 s for signalling circuit || 90 A - 500 ms for signalling circuit || 110 A - 100 ms for signalling circuit || 20 A 50°C - \u0026gt;= 15 min for power circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49020709568797,"sku":"DA-208408","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/schneider-electric-lp5k0901bw3-dropship-automation.webp?v=1752707543","url":"https:\/\/dropshipautomation.com\/products\/schneider-electric-lp5k0901bw3","provider":"Dropship Automation","version":"1.0","type":"link"}