{"product_id":"schneider-electric-lc2dt40m7","title":"SCHNEIDER-ELECTRIC LC2DT40M7","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003eLC2DT40M7\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUNSPSC\u003c\/dt\u003e\n\u003cdd\u003e39121529\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTariff Code\u003c\/dt\u003e\n\u003cdd\u003e8536490065\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCountry of Origin\u003c\/dt\u003e\n\u003cdd\u003eFR\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironment\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMechanical Robustness\u003c\/dt\u003e\n\u003cdd\u003evibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature For Operation\u003c\/dt\u003e\n\u003cdd\u003e-40-60°C || 60-70°C with derating\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e91 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eClimatic Withstand\u003c\/dt\u003e\n\u003cdd\u003eIACS E10 || IEC 60947-1 Annex Q category D\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePollution Degree\u003c\/dt\u003e\n\u003cdd\u003e3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNet Weight\u003c\/dt\u003e\n\u003cdd\u003e0.85 kg\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFlame Retardance\u003c\/dt\u003e\n\u003cdd\u003eV1 conforming to UL 94\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature For Storage\u003c\/dt\u003e\n\u003cdd\u003e-60-80°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtective Treatment\u003c\/dt\u003e\n\u003cdd\u003eTH IEC 60068-2-30\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIp Degree Of Protection\u003c\/dt\u003e\n\u003cdd\u003eIP20 front face IEC 60529\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating Altitude\u003c\/dt\u003e\n\u003cdd\u003e0...9842.52 ft (0...3000 m)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFire Resistance\u003c\/dt\u003e\n\u003cdd\u003e850°C IEC 60695-2-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e90 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e98 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eContractual warranty\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWarranty\u003c\/dt\u003e\n\u003cdd\u003e18 months\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eOffer Sustainability\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRohs Exemption Information\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMercury Free\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEnvironmental Disclosure\u003c\/dt\u003e\n\u003cdd\u003eENVPEP110229EN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSustainable Offer Status\u003c\/dt\u003e\n\u003cdd\u003eGreen Premium product\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePvc Free\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eToxic Heavy Metal Free\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReach Regulation\u003c\/dt\u003e\n\u003cdd\u003eFree of Substances of Very High Concern above the threshold\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCalifornia Proposition 65\u003c\/dt\u003e\n\u003cdd\u003eWARNING: This product can expose you to chemicals including: Antimony oxide \u0026amp; Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReach Free Of Svhc\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWeee\u003c\/dt\u003e\n\u003cdd\u003eThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eChina Rohs Regulation\u003c\/dt\u003e\n\u003cdd\u003ePro-active China RoHS declaration (out of China RoHS legal scope)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCircularity Profile\u003c\/dt\u003e\n\u003cdd\u003eENVEOLI110229EN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEu Rohs Directive\u003c\/dt\u003e\n\u003cdd\u003eCompliant\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eComplementary\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNon-Overlap Time\u003c\/dt\u003e\n\u003cdd\u003e1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMinimum Switching Current\u003c\/dt\u003e\n\u003cdd\u003e5 mA for signalling circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eControl Circuit Voltage Limits\u003c\/dt\u003e\n\u003cdd\u003e0.3...0.6 Uc -40-60°C drop-out AC 50\/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInsulation Resistance\u003c\/dt\u003e\n\u003cdd\u003e\u0026gt; 10 MOhm for signalling circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInrush Power In Va\u003c\/dt\u003e\n\u003cdd\u003e70-70 VA 60 Hz 0.75 20°C) || 70-70 VA 50 Hz 0.75 20°C)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCoil Technology\u003c\/dt\u003e\n\u003cdd\u003ewithout built-in suppressor module\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMinimum Switching Voltage\u003c\/dt\u003e\n\u003cdd\u003e17 V for signalling circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSignalling Circuit Frequency\u003c\/dt\u003e\n\u003cdd\u003e25...400 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeat Dissipation\u003c\/dt\u003e\n\u003cdd\u003e2-3 W 50\/60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAuxiliary Contacts Type\u003c\/dt\u003e\n\u003cdd\u003emechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHold-In Power Consumption In Va\u003c\/dt\u003e\n\u003cdd\u003e7.5-7.5 VA 20°C) 0.3 60 Hz || 7-7 VA 20°C) 0.3 50 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInterlocking Type\u003c\/dt\u003e\n\u003cdd\u003emechanical\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Uc] Control Circuit Voltage\u003c\/dt\u003e\n\u003cdd\u003e220 V AC 50\/60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ue] Rated Operational Voltage\u003c\/dt\u003e\n\u003cdd\u003epower circuit \u0026lt;= 690 V AC 25...400 Hz || power circuit \u0026lt;= 300 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower Dissipation Per Pole\u003c\/dt\u003e\n\u003cdd\u003e3.2 W AC-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAverage Impedance\u003c\/dt\u003e\n\u003cdd\u003e2 mOhm - Ith 40 A 50 Hz for power circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAuxiliary Contact Composition\u003c\/dt\u003e\n\u003cdd\u003e1 NO + 1 NC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ith] Conventional Free Air Thermal Current\u003c\/dt\u003e\n\u003cdd\u003e10 A (at 60°C) for signalling circuit || 40 A (at 60°C) for power circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting Support\u003c\/dt\u003e\n\u003cdd\u003erail || plate\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eControl Circuit Type\u003c\/dt\u003e\n\u003cdd\u003eAC 50\/60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\u003c\/dt\u003e\n\u003cdd\u003eCSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSafety Reliability Level\u003c\/dt\u003e\n\u003cdd\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eContactor Application\u003c\/dt\u003e\n\u003cdd\u003eresistive load\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Breaking Capacity\u003c\/dt\u003e\n\u003cdd\u003e450 A at 440 V for power circuit conforming to IEC 60947\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Or Component Type\u003c\/dt\u003e\n\u003cdd\u003echangeover contactor\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Certifications\u003c\/dt\u003e\n\u003cdd\u003eUL || CSA || CCC || EAC || UKCA || CB || EU-RO-MR by DNV-GL\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIrms Rated Making Capacity\u003c\/dt\u003e\n\u003cdd\u003e140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Name\u003c\/dt\u003e\n\u003cdd\u003eTeSys Deca\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssociated Fuse Rating\u003c\/dt\u003e\n\u003cdd\u003e10 A gG for signalling circuit conforming to IEC 60947-5-1 || 63 A gG at \u0026lt;= 690 V coordination type 1 for power circuit || 40 A gG at \u0026lt;= 690 V coordination type 2 for power circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/dt\u003e\n\u003cdd\u003e6 kV IEC 60947\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnections - Terminals\u003c\/dt\u003e\n\u003cdd\u003econtrol circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end || power circuit connector 1 2.5-10 mm²flexible without cable end || power circuit connector 2 2.5-10 mm²flexible without cable end || power circuit connector 1 2.5-10 mm²flexible with cable end || power circuit connector 2 2.5-10 mm²flexible with cable end || power circuit connector 1 2.5-16 mm²solid without cable end || power circuit connector 2 2.5-16 mm²solid without cable end\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRange\u003c\/dt\u003e\n\u003cdd\u003eTeSys || TeSys Deca\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePole Contact Composition\u003c\/dt\u003e\n\u003cdd\u003e4 NO\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice Presentation\u003c\/dt\u003e\n\u003cdd\u003epreassembled with reversing power busbar\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUtilisation Category\u003c\/dt\u003e\n\u003cdd\u003eAC-1 || AC-3 || AC-3e || AC-4\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ie] Rated Operational Current\u003c\/dt\u003e\n\u003cdd\u003e40 A (at \u0026lt;60°C) at \u0026lt;= 440 V AC AC-1 for power circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating Time\u003c\/dt\u003e\n\u003cdd\u003e12...22 ms closing || 4...19 ms opening\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Operating Rate\u003c\/dt\u003e\n\u003cdd\u003e3600 cyc\/h 60°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectrical Durability\u003c\/dt\u003e\n\u003cdd\u003e1.4 Mcycles 40 A AC-1 \u0026lt;= 440 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTightening Torque\u003c\/dt\u003e\n\u003cdd\u003econtrol circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m connector flat Ø 6 mm || power circuit 1.7 N.m connector Philips No 2 || power circuit 1.7 N.m screw clamp terminals pozidriv No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePoles Description\u003c\/dt\u003e\n\u003cdd\u003e4P\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOvervoltage Category\u003c\/dt\u003e\n\u003cdd\u003eIII\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ui] Rated Insulation Voltage\u003c\/dt\u003e\n\u003cdd\u003epower circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMechanical Durability\u003c\/dt\u003e\n\u003cdd\u003e15 Mcycles\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice Short Name\u003c\/dt\u003e\n\u003cdd\u003eLC2D\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Icw] Rated Short-Time Withstand Current\u003c\/dt\u003e\n\u003cdd\u003e50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtective Cover\u003c\/dt\u003e\n\u003cdd\u003ewith\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49058159231261,"sku":"DA-322198","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/schneider-electric-lc2dt40m7-dropship-automation.webp?v=1752993735","url":"https:\/\/dropshipautomation.com\/products\/schneider-electric-lc2dt40m7","provider":"Dropship Automation","version":"1.0","type":"link"}