{"product_id":"schneider-electric-lc1d126bl","title":"SCHNEIDER-ELECTRIC LC1D126BL","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003eLC1D126BL\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUNSPSC\u003c\/dt\u003e\n\u003cdd\u003e39121529\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTariff Code\u003c\/dt\u003e\n\u003cdd\u003e8536490065\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCountry of Origin\u003c\/dt\u003e\n\u003cdd\u003eFR\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironment\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Certifications\u003c\/dt\u003e\n\u003cdd\u003eGL || LROS (Lloyds register of shipping) || GOST || BV || CSA || UL || RINA || DNV || CCC || UKCA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e77 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\u003c\/dt\u003e\n\u003cdd\u003eCSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eClimatic Withstand\u003c\/dt\u003e\n\u003cdd\u003eIACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNet Weight\u003c\/dt\u003e\n\u003cdd\u003e0.485 kg\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFlame Retardance\u003c\/dt\u003e\n\u003cdd\u003eV1 conforming to UL 94\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtective Treatment\u003c\/dt\u003e\n\u003cdd\u003eTHIEC 60068-2-30\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIp Degree Of Protection\u003c\/dt\u003e\n\u003cdd\u003eIP20 front face IEC 60529\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMechanical Robustness\u003c\/dt\u003e\n\u003cdd\u003evibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating Altitude\u003c\/dt\u003e\n\u003cdd\u003e0...9842.52 ft (0...3000 m)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFire Resistance\u003c\/dt\u003e\n\u003cdd\u003e850°C IEC 60695-2-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e45 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e95 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePermissible Ambient Air Temperature Around The Device\u003c\/dt\u003e\n\u003cdd\u003e-40-60°C || 60-70°C with derating\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eContractual warranty\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWarranty\u003c\/dt\u003e\n\u003cdd\u003e18 months\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eOffer Sustainability\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRohs Exemption Information\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMercury Free\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEnvironmental Disclosure\u003c\/dt\u003e\n\u003cdd\u003eENVPEP110230EN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSustainable Offer Status\u003c\/dt\u003e\n\u003cdd\u003eGreen Premium product\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePvc Free\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eToxic Heavy Metal Free\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReach Regulation\u003c\/dt\u003e\n\u003cdd\u003eReference contains Substances of Very High Concern above the threshold\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCalifornia Proposition 65\u003c\/dt\u003e\n\u003cdd\u003eWARNING: This product can expose you to chemicals including: Antimony oxide \u0026amp; Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eChina Rohs Regulation\u003c\/dt\u003e\n\u003cdd\u003eProduct out of China RoHS scope. Substance declaration for your information.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCircularity Profile\u003c\/dt\u003e\n\u003cdd\u003eENVEOLI1102030EN\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEu Rohs Directive\u003c\/dt\u003e\n\u003cdd\u003eCompliant with Exemptions\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eComplementary\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNon-Overlap Time\u003c\/dt\u003e\n\u003cdd\u003e1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMinimum Switching Current\u003c\/dt\u003e\n\u003cdd\u003e5 mA for signalling circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower Dissipation Per Pole\u003c\/dt\u003e\n\u003cdd\u003e0.36 W AC-3 || 1.56 W AC-1 || 0.36 W AC-3e\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAverage Impedance\u003c\/dt\u003e\n\u003cdd\u003e2.5 mOhm - Ith 25 A 50 Hz for power circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAuxiliary Contact Composition\u003c\/dt\u003e\n\u003cdd\u003e1 NO + 1 NC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ith] Conventional Free Air Thermal Current\u003c\/dt\u003e\n\u003cdd\u003e25 A (at 60°C) for power circuit || 10 A (at 60°C) for signalling circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eControl Circuit Voltage Limits\u003c\/dt\u003e\n\u003cdd\u003e0.1...0.3 Uc -40-70°C drop-out DC || 0.8...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting Support\u003c\/dt\u003e\n\u003cdd\u003erail || plate\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eContact Compatibility\u003c\/dt\u003e\n\u003cdd\u003eM5\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eControl Circuit Type\u003c\/dt\u003e\n\u003cdd\u003eDC low consumption\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSafety Reliability Level\u003c\/dt\u003e\n\u003cdd\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePollution Degree\u003c\/dt\u003e\n\u003cdd\u003e3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHold-In Power Consumption In W\u003c\/dt\u003e\n\u003cdd\u003e2.4-2.4 W 20°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInsulation Resistance\u003c\/dt\u003e\n\u003cdd\u003e\u0026gt; 10 MOhm for signalling circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Breaking Capacity\u003c\/dt\u003e\n\u003cdd\u003e250 A at 440 V for power circuit conforming to IEC 60947\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIrms Rated Making Capacity\u003c\/dt\u003e\n\u003cdd\u003e250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssociated Fuse Rating\u003c\/dt\u003e\n\u003cdd\u003e10 A gG for signalling circuit conforming to IEC 60947-5-1 || 40 A gG at \u0026lt;= 690 V coordination type 1 for power circuit || 25 A gG at \u0026lt;= 690 V coordination type 2 for power circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/dt\u003e\n\u003cdd\u003e6 kV IEC 60947\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePole Contact Composition\u003c\/dt\u003e\n\u003cdd\u003e3 NO\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnections - Terminals\u003c\/dt\u003e\n\u003cdd\u003econtrol circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 8 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCoil Technology\u003c\/dt\u003e\n\u003cdd\u003ebuilt-in bidirectional peak limiting diode suppressor\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTime Constant\u003c\/dt\u003e\n\u003cdd\u003e40 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating Time\u003c\/dt\u003e\n\u003cdd\u003e77 ±15 % ms closing || 25 ±20 % ms opening\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMinimum Switching Voltage\u003c\/dt\u003e\n\u003cdd\u003e17 V for signalling circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Operating Rate\u003c\/dt\u003e\n\u003cdd\u003e3600 cyc\/h 60°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSignalling Circuit Frequency\u003c\/dt\u003e\n\u003cdd\u003e25...400 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTightening Torque\u003c\/dt\u003e\n\u003cdd\u003econtrol circuit 1.7 N.m lugs-ring terminals flat ˜ 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 1.7 N.m lugs-ring terminals flat ˜ 8 mm M3.5 || power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5 || power circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectrical Durability\u003c\/dt\u003e\n\u003cdd\u003e2 Mcycles 12 A AC-3 \u0026lt;= 440 V || 0.8 Mcycles 25 A AC-1 \u0026lt;= 440 V || 2 Mcycles 12 A AC-3e \u0026lt;= 440 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMechanical Durability\u003c\/dt\u003e\n\u003cdd\u003e30 Mcycles\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInrush Power In W\u003c\/dt\u003e\n\u003cdd\u003e2.4-2.4 W 20°C)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAuxiliary Contacts Type\u003c\/dt\u003e\n\u003cdd\u003emechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCompatibility Code\u003c\/dt\u003e\n\u003cdd\u003eLC1D\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOvervoltage Category\u003c\/dt\u003e\n\u003cdd\u003eIII\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Horse Power Rating\u003c\/dt\u003e\n\u003cdd\u003e0.5 hp at 115 V AC 50\/60 Hz for 1 phase motors || 2 hp at 230\/240 V AC 50\/60 Hz for 1 phase motors || 3 hp at 200\/208 V AC 50\/60 Hz for 3 phase motors || 3 hp at 230\/240 V AC 50\/60 Hz for 3 phase motors || 7.5 hp at 460\/480 V AC 50\/60 Hz for 3 phase motors || 10 hp at 575\/600 V AC 50\/60 Hz for 3 phase motors\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMotor Power Kw\u003c\/dt\u003e\n\u003cdd\u003e3 kW at 220...230 V AC 50\/60 Hz (AC-3) || 5.5 kW at 380...400 V AC 50\/60 Hz (AC-3) || 5.5 kW at 415 V AC 50\/60 Hz (AC-3) || 5.5 kW at 440 V AC 50\/60 Hz (AC-3) || 7.5 kW at 500 V AC 50\/60 Hz (AC-3) || 7.5 kW at 660...690 V AC 50\/60 Hz (AC-3) || 3 kW at 220...230 V AC 50\/60 Hz (AC-3e) || 5.5 kW at 380...400 V AC 50\/60 Hz (AC-3e) || 5.5 kW at 415 V AC 50\/60 Hz (AC-3e) || 5.5 kW at 440 V AC 50\/60 Hz (AC-3e) || 7.5 kW at 500 V AC 50\/60 Hz (AC-3e) || 7.5 kW at 660...690 V AC 50\/60 Hz (AC-3e) || 3.7 kW at 400 V AC 50\/60 Hz (AC-4)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ui] Rated Insulation Voltage\u003c\/dt\u003e\n\u003cdd\u003epower circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Icw] Rated Short-Time Withstand Current\u003c\/dt\u003e\n\u003cdd\u003e105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtective Cover\u003c\/dt\u003e\n\u003cdd\u003ewith\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Uc] Control Circuit Voltage\u003c\/dt\u003e\n\u003cdd\u003e24 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ue] Rated Operational Voltage\u003c\/dt\u003e\n\u003cdd\u003epower circuit \u0026lt;= 690 V AC 25...400 Hz || power circuit \u0026lt;= 300 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRange Of Product\u003c\/dt\u003e\n\u003cdd\u003eTeSys Deca\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eContactor Application\u003c\/dt\u003e\n\u003cdd\u003eresistive load || motor control\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Or Component Type\u003c\/dt\u003e\n\u003cdd\u003econtactor\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUtilisation Category\u003c\/dt\u003e\n\u003cdd\u003eAC-4 || AC-1 || AC-3 || AC-3e\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e[Ie] Rated Operational Current\u003c\/dt\u003e\n\u003cdd\u003e25 A (at \u0026lt;60°C) at \u0026lt;= 440 V AC AC-1 for power circuit || 12 A (at \u0026lt;60°C) at \u0026lt;= 440 V AC AC-3 for power circuit || 12 A (at \u0026lt;60°C) at \u0026lt;= 440 V AC AC-3e for power circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePoles Description\u003c\/dt\u003e\n\u003cdd\u003e3P\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice Short Name\u003c\/dt\u003e\n\u003cdd\u003eLC1D\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49120784318749,"sku":"DA-551479","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/dropship-automation_48d92b25-4bb3-438c-bf98-817e0fd6b3e3.webp?v=1731904118","url":"https:\/\/dropshipautomation.com\/products\/schneider-electric-lc1d126bl","provider":"Dropship Automation","version":"1.0","type":"link"}