{"product_id":"phoenix-contact-2878379","title":"PHOENIX-CONTACT 2878379","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e2878379\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUPC\u003c\/dt\u003e\n\u003cdd\u003e4046356073271\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCountry of Origin\u003c\/dt\u003e\n\u003cdd\u003eDE\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eNote\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUtilization restriction\u003c\/dt\u003e\n\u003cdd\u003eEMC: class A product, see manufacturer's declaration in the download area\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eDimensions\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e80 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e119.8 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e71.5 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNote on dimensions\u003c\/dt\u003e\n\u003cdd\u003eSpecfications with connectors\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eDigital inputs\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInput name\u003c\/dt\u003e\n\u003cdd\u003eDigital inputs\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDescription of the input\u003c\/dt\u003e\n\u003cdd\u003eEN 61131-2 type 1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection method\u003c\/dt\u003e\n\u003cdd\u003eInline connector\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection technology\u003c\/dt\u003e\n\u003cdd\u003e3-wire\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of inputs\u003c\/dt\u003e\n\u003cdd\u003e8\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTypical response time\u003c\/dt\u003e\n\u003cdd\u003eapprox. 500 µs\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtective circuit\u003c\/dt\u003e\n\u003cdd\u003eReverse polarity protection Suppressor diode\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal input voltage UIN\u003c\/dt\u003e\n\u003cdd\u003e24 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal input current at UIN\u003c\/dt\u003e\n\u003cdd\u003etyp. 3 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFilter time\u003c\/dt\u003e\n\u003cdd\u003e3 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInput voltage\u003c\/dt\u003e\n\u003cdd\u003e24 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInput voltage range \"0\" signal\u003c\/dt\u003e\n\u003cdd\u003e-30 V DC - 5 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInput voltage range \"1\" signal\u003c\/dt\u003e\n\u003cdd\u003e15 V DC - 30 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTypical input current per channel\u003c\/dt\u003e\n\u003cdd\u003etyp. 3 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDelay at signal change from 0 to 1\u003c\/dt\u003e\n\u003cdd\u003e5 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDelay at signal change from 1 to 0\u003c\/dt\u003e\n\u003cdd\u003e5 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eAmbient conditions\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature (operation)\u003c\/dt\u003e\n\u003cdd\u003e-25°C - 55°C (observe derating)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature (storage\/transport)\u003c\/dt\u003e\n\u003cdd\u003e-40°C - 85°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePermissible humidity (operation)\u003c\/dt\u003e\n\u003cdd\u003e10 % - 95 % (according to DIN EN 61131-2)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePermissible humidity (storage\/transport)\u003c\/dt\u003e\n\u003cdd\u003e10 % - 95 % (according to DIN EN 61131-2)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAir pressure (operation)\u003c\/dt\u003e\n\u003cdd\u003e80 kPa - 106 kPa (up to 3000 m above sea level)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAir pressure (storage\/transport)\u003c\/dt\u003e\n\u003cdd\u003e70 kPa - 106 kPa (up to 3000 m above sea level)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDegree of protection\u003c\/dt\u003e\n\u003cdd\u003eIP20\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironmental Product Compliance\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eREACh SVHC\u003c\/dt\u003e\n\u003cdd\u003eLead 7439-92-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eChina RoHS\u003c\/dt\u003e\n\u003cdd\u003eEnvironmentally Friendly Use Period = 50 years\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eChina RoHS\u003c\/dt\u003e\n\u003cdd\u003eFor details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eDigital outputs\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOutput name\u003c\/dt\u003e\n\u003cdd\u003eDigital outputs\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection method\u003c\/dt\u003e\n\u003cdd\u003eInline connector\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection technology\u003c\/dt\u003e\n\u003cdd\u003e3-wire\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of outputs\u003c\/dt\u003e\n\u003cdd\u003e4\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtective circuit\u003c\/dt\u003e\n\u003cdd\u003eShort-circuit and overload protection Free running circuit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOutput voltage\u003c\/dt\u003e\n\u003cdd\u003e24 V DC -1 V (At nominal current)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal output voltage\u003c\/dt\u003e\n\u003cdd\u003e24 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum output current per channel\u003c\/dt\u003e\n\u003cdd\u003e500 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum output current per module \/ terminal block\u003c\/dt\u003e\n\u003cdd\u003e2 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum output current per module\u003c\/dt\u003e\n\u003cdd\u003e2 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal load, inductive\u003c\/dt\u003e\n\u003cdd\u003e12 VA (1.2 H, 48 ©)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal load, lamp\u003c\/dt\u003e\n\u003cdd\u003e12 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal load, ohmic\u003c\/dt\u003e\n\u003cdd\u003e12 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLimitation of the voltage induced on circuit interruption\u003c\/dt\u003e\n\u003cdd\u003eapprox. -30 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOutput current when switched off\u003c\/dt\u003e\n\u003cdd\u003emax. 10 µA (When not loaded, a voltage can be measured even at an output that is not set.)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eBehavior with overload\u003c\/dt\u003e\n\u003cdd\u003eAuto restart\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eBehavior with inductive overload\u003c\/dt\u003e\n\u003cdd\u003eOutput can be destroyed\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReverse voltage resistance to short pulses\u003c\/dt\u003e\n\u003cdd\u003eReverse voltage proof\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eInterfaces\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesignation\u003c\/dt\u003e\n\u003cdd\u003ePROFINET\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNo. of channels\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection method\u003c\/dt\u003e\n\u003cdd\u003eSC-RJ socket\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWavelength\u003c\/dt\u003e\n\u003cdd\u003e660 nm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTransmission speed\u003c\/dt\u003e\n\u003cdd\u003e100 Mbps (acc. to PROFINET standard)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesignation\u003c\/dt\u003e\n\u003cdd\u003eInline local bus\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection method\u003c\/dt\u003e\n\u003cdd\u003eInline data jumper\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTransmission speed\u003c\/dt\u003e\n\u003cdd\u003e500 kbps \/ 2 Mbps (automatic detection, no combined system)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eStandards and Regulations\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMechanical tests\u003c\/dt\u003e\n\u003cdd\u003eVibration resistance in acc. with EN 60068-2-6\/IEC 60068-2-6 5g\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMechanical tests\u003c\/dt\u003e\n\u003cdd\u003eShock in acc. with EN 60068-2-27\/IEC 60068-2-27 Operation: 25g, 11 ms duration, semi-sinusoidal shock impulse\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtection class\u003c\/dt\u003e\n\u003cdd\u003eIII (IEC 61140, EN 61140, VDE 0140-1)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003ePower supply for module electronics\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection method\u003c\/dt\u003e\n\u003cdd\u003eSpring-cage connection\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesignation\u003c\/dt\u003e\n\u003cdd\u003eBus coupler supply UBC; Communications power UL (7.5 V) and the analog supply UANA (24 V) are generated from the bus coupler supply.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply voltage\u003c\/dt\u003e\n\u003cdd\u003e24 V DC (via Inline connector)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply voltage range\u003c\/dt\u003e\n\u003cdd\u003e19.2 V DC - 30 V DC (including all tolerances, including ripple)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply current\u003c\/dt\u003e\n\u003cdd\u003e250 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent consumption\u003c\/dt\u003e\n\u003cdd\u003etyp. 250 mA (from UBK)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent consumption\u003c\/dt\u003e\n\u003cdd\u003emax. 0.83 A DC (from UBK)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower dissipation\u003c\/dt\u003e\n\u003cdd\u003etyp. 3 W (entire device)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eInline potentials\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesignation\u003c\/dt\u003e\n\u003cdd\u003eBus coupler supply UBC; Communications power UL (7.5 V) and the analog supply UANA (24 V) are generated from the bus coupler supply.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply voltage\u003c\/dt\u003e\n\u003cdd\u003e24 V DC (via Inline connector)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply voltage range\u003c\/dt\u003e\n\u003cdd\u003e19.2 V DC - 30 V DC (including all tolerances, including ripple)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent consumption\u003c\/dt\u003e\n\u003cdd\u003e50 mA (without connected I\/O terminal blocks)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent consumption\u003c\/dt\u003e\n\u003cdd\u003etyp. 250 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent consumption\u003c\/dt\u003e\n\u003cdd\u003emax. 0.83 A DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesignation\u003c\/dt\u003e\n\u003cdd\u003eCommunications power (UL)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply voltage\u003c\/dt\u003e\n\u003cdd\u003e7.5 V DC ±5 %\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower supply unit\u003c\/dt\u003e\n\u003cdd\u003emax. 0.8 A DC (observe derating)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesignation\u003c\/dt\u003e\n\u003cdd\u003eSupply of analog modules (UANA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply voltage\u003c\/dt\u003e\n\u003cdd\u003e24 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower supply unit\u003c\/dt\u003e\n\u003cdd\u003emax. 0.5 A DC (observe derating)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesignation\u003c\/dt\u003e\n\u003cdd\u003eMain circuit supply (UM)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower supply unit\u003c\/dt\u003e\n\u003cdd\u003emax. 8 A DC (Sum of UM + US; 4 A, maximum, when used in potentially explosive areas.)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent consumption\u003c\/dt\u003e\n\u003cdd\u003e3 mA (without sensors)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent consumption\u003c\/dt\u003e\n\u003cdd\u003emax. 8 A DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesignation\u003c\/dt\u003e\n\u003cdd\u003eSegment circuit supply (US)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent consumption\u003c\/dt\u003e\n\u003cdd\u003e3 mA (without actuators)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49045746581789,"sku":"DA-296545","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/phoenix-contact-2878379-dropship-automation.webp?v=1752928570","url":"https:\/\/dropshipautomation.com\/products\/phoenix-contact-2878379","provider":"Dropship Automation","version":"1.0","type":"link"}