{"product_id":"phoenix-contact-2810230","title":"PHOENIX-CONTACT 2810230","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e2810230\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUPC\u003c\/dt\u003e\n\u003cdd\u003e4046356009959\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCountry of Origin\u003c\/dt\u003e\n\u003cdd\u003eDE\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\"grid items-center gap-x-4 px-4 \"\u003e\n\u003cdt\u003eETIM\u003c\/dt\u003e\n\u003cdd\u003e\u003cdl\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eGroup Code : EG000026\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eGroup Description : Sensors\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eClass Description : Isolation amplifier\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eClass Code : EC002653\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eVersion : 7\u003c\/dd\u003e\u003c\/div\u003e\n\u003c\/dl\u003e\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eInput data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDescription of the input\u003c\/dt\u003e\n\u003cdd\u003eCurrent input (sensor circuit)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of inputs\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent input signal\u003c\/dt\u003e\n\u003cdd\u003e4 mA - 20 mA (repeater power supply and isolator operation)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent input signal\u003c\/dt\u003e\n\u003cdd\u003e0 mA - 20 mA (isolator operation)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInput resistance current input\u003c\/dt\u003e\n\u003cdd\u003eapprox. 50 ©\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTransmitter supply voltage\u003c\/dt\u003e\n\u003cdd\u003e16.5 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eDimensions\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e6.2 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e93.1 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e102.5 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eConnection data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection method\u003c\/dt\u003e\n\u003cdd\u003eSpring-cage connection\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStripping length\u003c\/dt\u003e\n\u003cdd\u003e8 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConductor cross section solid\u003c\/dt\u003e\n\u003cdd\u003e0.2 mm² - 2.5 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConductor cross section flexible\u003c\/dt\u003e\n\u003cdd\u003e0.2 mm² - 2.5 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConductor cross section AWG\u003c\/dt\u003e\n\u003cdd\u003e24 - 12\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eOutput data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOutput name\u003c\/dt\u003e\n\u003cdd\u003eCurrent output\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of outputs\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent output signal\u003c\/dt\u003e\n\u003cdd\u003e4 mA - 20 mA (repeater power supply and isolator operation)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent output signal\u003c\/dt\u003e\n\u003cdd\u003e0 mA - 20 mA (isolator operation)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMax. output current\u003c\/dt\u003e\n\u003cdd\u003e\u0026gt; 21 mA (22.5 mA, typical)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLoad\/output load current output\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 500 © (I = 20 mA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRipple\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt; 20 mVrms (at 500 ©)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTransmission Behavior\u003c\/dt\u003e\n\u003cdd\u003e1:1 to input signal\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eData communication (bypass)\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLimit frequency (3 dB)\u003c\/dt\u003e\n\u003cdd\u003eapprox. 2.5 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eAmbient conditions\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature (operation)\u003c\/dt\u003e\n\u003cdd\u003e-20°C - 60°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature (storage\/transport)\u003c\/dt\u003e\n\u003cdd\u003e-40°C - 85°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDegree of protection\u003c\/dt\u003e\n\u003cdd\u003eIP20\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNoise immunity\u003c\/dt\u003e\n\u003cdd\u003eEN 61000-6-2 When being exposed to interference, there may be minimal deviations.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironmental Product Compliance\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eChina RoHS\u003c\/dt\u003e\n\u003cdd\u003eEnvironmentally Friendly Use Period = 50 years\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eChina RoHS\u003c\/dt\u003e\n\u003cdd\u003eFor details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEMC data\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesignation\u003c\/dt\u003e\n\u003cdd\u003eElectromagnetic RF field\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\/regulations\u003c\/dt\u003e\n\u003cdd\u003eEN 61000-4-3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTypical deviation from the measuring range final value\u003c\/dt\u003e\n\u003cdd\u003e3 %\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesignation\u003c\/dt\u003e\n\u003cdd\u003eFast transients (burst)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\/regulations\u003c\/dt\u003e\n\u003cdd\u003eEN 61000-4-4\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesignation\u003c\/dt\u003e\n\u003cdd\u003eConducted interferences\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\/regulations\u003c\/dt\u003e\n\u003cdd\u003eEN 61000-4-6\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eStandards and Regulations\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectromagnetic compatibility\u003c\/dt\u003e\n\u003cdd\u003eConformance with EMC directive\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNoise emission\u003c\/dt\u003e\n\u003cdd\u003eEN 61000-6-4\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\/regulations\u003c\/dt\u003e\n\u003cdd\u003eEN 61000-4-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesignation\u003c\/dt\u003e\n\u003cdd\u003eElectromagnetic RF field\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\/regulations\u003c\/dt\u003e\n\u003cdd\u003eEN 61000-4-3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\/regulations\u003c\/dt\u003e\n\u003cdd\u003eEN 61000-4-4\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\/regulations\u003c\/dt\u003e\n\u003cdd\u003eEN 61000-4-5\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDesignation\u003c\/dt\u003e\n\u003cdd\u003eConducted interferences\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\/regulations\u003c\/dt\u003e\n\u003cdd\u003eEN 61000-4-6\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectrical isolation\u003c\/dt\u003e\n\u003cdd\u003eBasic insulation according to EN 61010\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConformance\u003c\/dt\u003e\n\u003cdd\u003eCE-compliant\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eATEX\u003c\/dt\u003e\n\u003cdd\u003eII 3 G Ex nA IIC T4 Gc X\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUL, USA\/Canada\u003c\/dt\u003e\n\u003cdd\u003eUL 508 Listed\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUL, USA\/Canada\u003c\/dt\u003e\n\u003cdd\u003eClass I, Div. 2, Groups A, B, C, D T4\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUL, USA\/Canada\u003c\/dt\u003e\n\u003cdd\u003eClass I, Zone 2, Group IIC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003ePower supply\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal supply voltage\u003c\/dt\u003e\n\u003cdd\u003e24 V DC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSupply voltage range\u003c\/dt\u003e\n\u003cdd\u003e20.4 V DC - 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5\/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt; 900 mW (at 24 V DC and in repeater power supply operation)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt; 600 mW (at 24 V DC and in isolator operation)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49042052251933,"sku":"DA-289474","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/phoenix-contact-2810230-dropship-automation.webp?v=1752911005","url":"https:\/\/dropshipautomation.com\/products\/phoenix-contact-2810230","provider":"Dropship Automation","version":"1.0","type":"link"}