{"product_id":"phoenix-contact-2800742","title":"PHOENIX-CONTACT 2800742","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e2800742\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUPC\u003c\/dt\u003e\n\u003cdd\u003e4046356641968\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCountry of Origin\u003c\/dt\u003e\n\u003cdd\u003eDE\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\"grid items-center gap-x-4 px-4 \"\u003e\n\u003cdt\u003eETIM\u003c\/dt\u003e\n\u003cdd\u003e\u003cdl\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eGroup Code : EG000021\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eGroup Description : Earthing, lightning and surge protection\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eClass Description : Surge protection device for power supply systems\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eClass Code : EC000941\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eVersion : 7\u003c\/dd\u003e\u003c\/div\u003e\n\u003c\/dl\u003e\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eUL specifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSPD Type\u003c\/dt\u003e\n\u003cdd\u003e4CA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum continuous operating voltage MCOV (L-N)\u003c\/dt\u003e\n\u003cdd\u003e440 V AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNom. voltage\u003c\/dt\u003e\n\u003cdd\u003e347 V AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMode of protection\u003c\/dt\u003e\n\u003cdd\u003eL-N\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower distribution system\u003c\/dt\u003e\n\u003cdd\u003eSingle phase\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal frequency\u003c\/dt\u003e\n\u003cdd\u003e50\/60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMeasured limiting voltage MLV (L-N)\u003c\/dt\u003e\n\u003cdd\u003e2280 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal discharge current In (L-N)\u003c\/dt\u003e\n\u003cdd\u003e20 kA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eDimensions\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e52.4 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e17.5 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e55.3 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHorizontal pitch\u003c\/dt\u003e\n\u003cdd\u003e1 Div.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eAmbient conditions\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDegree of protection\u003c\/dt\u003e\n\u003cdd\u003eIP20\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature (operation)\u003c\/dt\u003e\n\u003cdd\u003e-40°C - 80°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient temperature (storage\/transport)\u003c\/dt\u003e\n\u003cdd\u003e-40°C - 80°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAltitude\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 2000 m (amsl (above mean sea level))\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePermissible humidity (operation)\u003c\/dt\u003e\n\u003cdd\u003e5 % - 95 %\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShock (operation)\u003c\/dt\u003e\n\u003cdd\u003e25g (Half-sine \/ 11 ms \/ 3x ±X, ±Y, ±Z)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVibration (operation)\u003c\/dt\u003e\n\u003cdd\u003e5g (10 - 500 Hz \/ 2.5 h \/ X, Y, Z)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eProtective circuit\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal voltage UN\u003c\/dt\u003e\n\u003cdd\u003e240\/415 V AC (TN)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal voltage UN\u003c\/dt\u003e\n\u003cdd\u003e240\/415 V AC (TT)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal frequency fN\u003c\/dt\u003e\n\u003cdd\u003e60 Hz (50 Hz)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum continuous voltage UC\u003c\/dt\u003e\n\u003cdd\u003e440 V AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResidual current IPE\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 0.45 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandby power consumption PC\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 200 mVA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNominal discharge current In (8\/20) µs\u003c\/dt\u003e\n\u003cdd\u003e20 kA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum discharge current Imax (8\/20) µs\u003c\/dt\u003e\n\u003cdd\u003e40 kA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit current rating ISCCR\u003c\/dt\u003e\n\u003cdd\u003e25 kA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage protection level Up\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 2.2 kV\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResidual voltage Ures\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 2.2 kV (at In)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResidual voltage Ures\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 1.8 kV (at 10 kA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResidual voltage Ures\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 1.5 kV (at 5 kA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResidual voltage Ures\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 1.4 kV (at 3 kA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTOV behavior at UT\u003c\/dt\u003e\n\u003cdd\u003e440 V AC (5 s \/ withstand mode)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTOV behavior at UT\u003c\/dt\u003e\n\u003cdd\u003e440 V AC (120 min \/ withstand mode)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResponse time tA\u003c\/dt\u003e\n\u003cdd\u003e‰¤ 25 ns\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMax. backup fuse with branch wiring\u003c\/dt\u003e\n\u003cdd\u003e125 A (gG)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eStandards and Regulations\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\/regulations\u003c\/dt\u003e\n\u003cdd\u003eIEC 61643-11 2011\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStandards\/regulations\u003c\/dt\u003e\n\u003cdd\u003eEN 61643-11 2012\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49087738511645,"sku":"DA-414574","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/phoenix-contact-2800742-dropship-automation.webp?v=1753932211","url":"https:\/\/dropshipautomation.com\/products\/phoenix-contact-2800742","provider":"Dropship Automation","version":"1.0","type":"link"}