{"product_id":"fluke-fp-probe","title":"FLUKE FP Probe","description":"\u003ch2 class=\" \"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003eFP Probe\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eUPC\u003c\/dt\u003e\n\u003cdd\u003e095969298711\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eInfrared Specifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eDistance to spot size\/Optical resolution (D:S)\u003c\/dt\u003e\n\u003cdd\u003e2.5:1 @ 90% energy, typical\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eResponse time\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt; 500 ms after initial reading\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eIllumination to IR channel offset\u003c\/dt\u003e\n\u003cdd\u003e13 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTemperature\u003c\/dt\u003e\n\u003cdd\u003e-35¡C to 275¡C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTypical working range (target illumination)\u003c\/dt\u003e\n\u003cdd\u003eÅ25 mm to 250 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMinimum target size\u003c\/dt\u003e\n\u003cdd\u003e12 mm ¿\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eSpectral response\u003c\/dt\u003e\n\u003cdd\u003e8-14 microns\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAccuracy\u003c\/dt\u003e\n\u003cdd\u003eAbove 65¡C): ±1.5% of reading\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eEmissivity\u003c\/dt\u003e\n\u003cdd\u003ePre-set for foodservice applications\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAccuracy\u003c\/dt\u003e\n\u003cdd\u003eBelow 0¡C: ±1¡ ±0.1 degree\/degree\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAccuracy\u003c\/dt\u003e\n\u003cdd\u003e(Assumes ambient operating temperature of 23¡C ±2¡)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAccuracy\u003c\/dt\u003e\n\u003cdd\u003eBetween 0¡C and 65¡C: ±1¡C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eOperational Specifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eEnvironmental data\u003c\/dt\u003e\n\u003cdd\u003eIP54 sealing (hand-washable, non-submersible)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eDimensions\u003c\/dt\u003e\n\u003cdd\u003e165 x 32 x 50 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eDisplay resolution\u003c\/dt\u003e\n\u003cdd\u003e4 digits, 0.1¡C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTarget illumination\u003c\/dt\u003e\n\u003cdd\u003eHigh brightness LED\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eDisplayhold (7seconds)\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTimer\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eLCD backlit display\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMaximum temperature displayed\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eBattery life\u003c\/dt\u003e\n\u003cdd\u003eAlkaline: 10 hours minimum @ 23¡C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePower, battery life\u003c\/dt\u003e\n\u003cdd\u003e9 V alkaline\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTemperature display\u003c\/dt\u003e\n\u003cdd\u003e4 digits, 0.1¡C resolution\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eRelative humidity\u003c\/dt\u003e\n\u003cdd\u003e90% (±5%) RH non condensing @ 30¡C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eStorage temperature\u003c\/dt\u003e\n\u003cdd\u003e-20¡C to 60¡C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAmbient operating range\u003c\/dt\u003e\n\u003cdd\u003e0¡C to 50¡C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eWeight\u003c\/dt\u003e\n\u003cdd\u003e150 g (with battery)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eRepeatability\u003c\/dt\u003e\n\u003cdd\u003eWithin accuracy specifications of the unit\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eOverview\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eReceiving:\u003c\/dt\u003e\n\u003cdd\u003eUse FoodPro Plus thermometer to quickly verify proper temperatures of food products at the point of delivery as recommended by your HACCP program.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eFood holding:\u003c\/dt\u003e\n\u003cdd\u003eEasily monitor hot and cold food holding. HACCP check lights provide instant recognition of safe\/unsafe temperatures.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eInspection:\u003c\/dt\u003e\n\u003cdd\u003eConduct food line inspections daily to ensure compliance with local food temperature monitoring requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eEquipment Calibration:\u003c\/dt\u003e\n\u003cdd\u003eVerify proper operating temperature of coolers, freezers, grills, fryers, warmers, as well as hot and cold storage units to avoid inconsistent food service, costly spoilage and to allow quicker response, reducing equipment repair costs.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eDining room:\u003c\/dt\u003e\n\u003cdd\u003eEasily verify temperatures in every aspect of food serving to ensure safety, enhance quality and reduce waste.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eOther Specifications (Both)\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eOptions\/Accessories\u003c\/dt\u003e\n\u003cdd\u003eAt calibration geometry of 279 mm with a 140 mm diameter, 0.97 emissivity blackbody. Specifications subject to change without notice.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eOptions\/Accessories\u003c\/dt\u003e\n\u003cdd\u003eReplacement probe\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCertifications\u003c\/dt\u003e\n\u003cdd\u003eCE NSF\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCalibration certificate\u003c\/dt\u003e\n\u003cdd\u003eCalibration accuracy with NIST and DKD traceability\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eStandards\u003c\/dt\u003e\n\u003cdd\u003eConforms to EN 61236-1 Electromagnetic Emissions and Susceptibility, EN 6101-1 General Safety, Sealing IP54 (hand washable, non-submersible)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eWarranty\u003c\/dt\u003e\n\u003cdd\u003e2 years\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eProbe Specifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eProbe dimensions\u003c\/dt\u003e\n\u003cdd\u003eLength: 90 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eSensor type\u003c\/dt\u003e\n\u003cdd\u003eThin-film platinum, class A, Resistance\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAccuracy\u003c\/dt\u003e\n\u003cdd\u003eBelow Ð5¡C: ±1¡C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eProbe dimensions\u003c\/dt\u003e\n\u003cdd\u003eDiameter: 3.0 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTemperature\u003c\/dt\u003e\n\u003cdd\u003e-40¡C to 200¡C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAccuracy\u003c\/dt\u003e\n\u003cdd\u003e(Assumes ambient operating temperature of 23¡C ±2¡)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eSensor type\u003c\/dt\u003e\n\u003cdd\u003eThermal device (RTD)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAccuracy\u003c\/dt\u003e\n\u003cdd\u003eBetween Ð5¡C and 65¡C: ±0.5¡C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eResponse time\u003c\/dt\u003e\n\u003cdd\u003e7-8 seconds (3 time constants)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAccuracy\u003c\/dt\u003e\n\u003cdd\u003eAbove 65¡C: ±1% of reading\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49523323404573,"sku":"DA-1133572","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/dropship-automation_e5966a92-4faf-4ed3-b3c6-2b35d2ff7ffb.webp?v=1735752919","url":"https:\/\/dropshipautomation.com\/products\/fluke-fp-probe","provider":"Dropship Automation","version":"1.0","type":"link"}