{"product_id":"fluke-fluke-1621","title":"FLUKE FLUKE 1621","description":"\u003ch2 class=\" \"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003eFLUKE 1621\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eUPC\u003c\/dt\u003e\n\u003cdd\u003e095969401210\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eGeneral Specifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMeasuring functions\u003c\/dt\u003e\n\u003cdd\u003e3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eIntrinsic error\u003c\/dt\u003e\n\u003cdd\u003eRefers to the reference temperature range and is guaranteed for one year\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMeasuring rate\u003c\/dt\u003e\n\u003cdd\u003e2 measurements\/second\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eBattery1\u003c\/dt\u003e\n\u003cdd\u003eOne 9 volt alkaline (LR61)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eBattery condition\u003c\/dt\u003e\n\u003cdd\u003eLO-BAT is displayed if voltage drops below 6.5 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eVoltages Between jacks H\/C2 and E\/C1\u003c\/dt\u003e\n\u003cdd\u003e250 Veff maximum (effective voltage)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eVoltages Between jacks S\/P2 and E\/C1\u003c\/dt\u003e\n\u003cdd\u003e250 Veff maximum\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eClimatic class\u003c\/dt\u003e\n\u003cdd\u003eVDE\/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4\/87)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTemperature performance2\u003c\/dt\u003e\n\u003cdd\u003eWorking: -10¡C to +50¡C (+14¡F to +122¡F)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTemperature performance\u003c\/dt\u003e\n\u003cdd\u003eOperating: 0¡C to +35¡C (+32¡F to +95¡F)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTemperature performance Storage\u003c\/dt\u003e\n\u003cdd\u003e-20¡C to +60¡C (+68¡F to +140¡F)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTemperature performance Reference\u003c\/dt\u003e\n\u003cdd\u003e+23¡C ±2¡C (+73¡F ±4¡F)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTemperature coefficient\u003c\/dt\u003e\n\u003cdd\u003e±0.1% of range per degree Kelvin\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eSafety\u003c\/dt\u003e\n\u003cdd\u003eIEC\/EN 61010-1, 600 V CAT II, pollution degree 2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eDimensions\u003c\/dt\u003e\n\u003cdd\u003e113 x 54 x 216 mm (4.5 x 2.1 x 8.5 in), including holster\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eWeight\u003c\/dt\u003e\n\u003cdd\u003e850 g (1.9 lb), including standard accessories, volume approximately 600 cm3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eMeasuring Range\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e0.15 ? to 20 ? Resolution\u003c\/dt\u003e\n\u003cdd\u003e0.01 ?\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e0.15 ? to 20 ? Display range\u003c\/dt\u003e\n\u003cdd\u003e0 to 19.99 ?\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e200 ? Resolution\u003c\/dt\u003e\n\u003cdd\u003e0.1 ?\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e200 ? Display range\u003c\/dt\u003e\n\u003cdd\u003e20 to 199.9 ?\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e2 k? Resolution\u003c\/dt\u003e\n\u003cdd\u003e1 ?\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e2 k? Display range\u003c\/dt\u003e\n\u003cdd\u003e200 to 1999 ?\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eIntrinsic Uncertainty\u003c\/dt\u003e\n\u003cdd\u003e±(6% of measured value + 5D)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eOperating uncertainty IEC 615573\u003c\/dt\u003e\n\u003cdd\u003e±(18% of measured value + 5D)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eElectrical Specifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMaximum deviations E1 Influence factor\u003c\/dt\u003e\n\u003cdd\u003ePosition\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMaximum deviations\u003c\/dt\u003e\n\u003cdd\u003eE1 Deviation influence: 0% || E2 Deviation influence: 0% || E3 Deviation influence: 2.3% || E4 Deviation influence: 0.6% || E5 Deviation influence: 10%\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMaximum deviations E2 Influence factor\u003c\/dt\u003e\n\u003cdd\u003eSupply voltage\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMaximum deviations E3 Influence factor\u003c\/dt\u003e\n\u003cdd\u003eTemperature E3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMaximum deviations E4 Influence factor\u003c\/dt\u003e\n\u003cdd\u003eSerial interference voltage (20 V)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMaximum deviations E5 Influence factor\u003c\/dt\u003e\n\u003cdd\u003eProbe- and auxiliary probe resistance\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTest voltage\u003c\/dt\u003e\n\u003cdd\u003e3.7 kV\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eProtection type\u003c\/dt\u003e\n\u003cdd\u003eIP 40; IEC\/EN 60529\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eElectromagnetic compatibility Emission\u003c\/dt\u003e\n\u003cdd\u003eIEC\/EN 61326 Class B\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eElectromagnetic compatibility\u003c\/dt\u003e\n\u003cdd\u003eImmunity: IEC\/EN 61326 Annex C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eRE Resistance measurement\u003c\/dt\u003e\n\u003cdd\u003eMeasuring method: Current-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC\/EN 61557Ð5\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eR Open circuit voltage\u003c\/dt\u003e\n\u003cdd\u003e23 to 24 V AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eR Short circuit current\u003c\/dt\u003e\n\u003cdd\u003e\u0026gt; 50 mA AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eR\u003c\/dt\u003e\n\u003cdd\u003eMeasuring frequency: 128 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eR Maximum permissible overload\u003c\/dt\u003e\n\u003cdd\u003e250 Veff\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eMeasuring time\u003c\/dt\u003e\n\u003cdd\u003e8 seconds (average from when START is pressed)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eLimit input\u003c\/dt\u003e\n\u003cdd\u003eTester retains set value even if instrument is turned off (assuming battery power supply is sufficient)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAutomatic changeover of resolution RH\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt; 7 k? || \u0026lt; 50 k? || \u0026gt; 50 k?\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAutomatic changeover of resolution Resolution\u003c\/dt\u003e\n\u003cdd\u003e0.01 ? || 0.1 ? || 1 ?\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eInterference voltage display DC + AC\u003c\/dt\u003e\n\u003cdd\u003eVmax: 30 Veff || Common mode rejection: \u0026gt; 80 dB at 50 Hz and 60 Hz || Measuring uncertainty: \u0026lt; 10% for pure AC and DC signals\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eInterference voltage display DC + AC Ri\u003c\/dt\u003e\n\u003cdd\u003e680 k?\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49524896203037,"sku":"DA-1140372","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/dropship-automation_1597b698-edf7-4bce-8bd3-1f29ef1957e7.webp?v=1735790005","url":"https:\/\/dropshipautomation.com\/products\/fluke-fluke-1621","provider":"Dropship Automation","version":"1.0","type":"link"}