{"product_id":"fluke-fluke-1550c","title":"FLUKE FLUKE 1550C","description":"\u003ch2 class=\" \"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003eFLUKE 1550C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eUPC\u003c\/dt\u003e\n\u003cdd\u003e095969550918\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eTest voltage (DC)\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e250 V Range\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt; 250 k?,250 k? to 5 G?5 G? to 50 G?\u0026gt; 50 G?\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e250 V\u003c\/dt\u003e\n\u003cdd\u003eAccuracy (± reading): Unspecified5%20%Unspecified\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e500 V Range\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt; 500 k?500 k? to 10 G?10 G? to 100 G?\u0026gt; 100 G?\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e500 V\u003c\/dt\u003e\n\u003cdd\u003eAccuracy (± reading): Unspecified5%20%Unspecified\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e1000 V Range\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt; 1 M?1 M? to 20 G?20 G? to 200 G?\u0026gt; 200 G?\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e1000 V\u003c\/dt\u003e\n\u003cdd\u003eAccuracy (± reading): Unspecified5%20%Unspecified\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e2500 V Range\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt; 2.5 M?2.5 M? to 50 G?50 G? to 500 G?\u0026gt; 500 G?\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e2500 V\u003c\/dt\u003e\n\u003cdd\u003eAccuracy (± reading): Unspecified5%20%Unspecified\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e5000 V Range\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt; 5 M?5 M? to 100 G?100 G? to 1 T?\u0026gt; 1 T?\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003e5000 V\u003c\/dt\u003e\n\u003cdd\u003eAccuracy (± reading): Unspecified5%20%Unspecified\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eBar graph range\u003c\/dt\u003e\n\u003cdd\u003e0 to 1 T? (1550C) - 0 to 2 T? (1555)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eInsulation test voltage accuracy\u003c\/dt\u003e\n\u003cdd\u003e-0%, +10% at 1 mA load current\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eInduced AC mains current rejection\u003c\/dt\u003e\n\u003cdd\u003e2 mA maximum\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCharging rate for capacitive load\u003c\/dt\u003e\n\u003cdd\u003e5 seconds per ?F\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eDischarge rate for capacitive load\u003c\/dt\u003e\n\u003cdd\u003e1.5 s\/?F\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eLeakage current measurement Range\u003c\/dt\u003e\n\u003cdd\u003e1 nA to 2 mA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eLeakage current measurement Accuracy\u003c\/dt\u003e\n\u003cdd\u003e± (5% + 2 nA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCapacitance measurement Range\u003c\/dt\u003e\n\u003cdd\u003e0.01 ?F to 15.00 ?F\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCapacitance measurement Accuracy\u003c\/dt\u003e\n\u003cdd\u003e± (15% rdg + 0.03 ?F)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTimer Range\u003c\/dt\u003e\n\u003cdd\u003e0 to 99 minutes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTimer\u003c\/dt\u003e\n\u003cdd\u003eResolution setting: 1 minute || Resolution indication: 1 second\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eLive circuit warning\u003c\/dt\u003e\n\u003cdd\u003eWarning range: 30 V to 660 V AC\/DC, 50\/60 Hz || Voltage accuracy: ± (15% + 2 V)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eSoftware specifications\u003c\/dt\u003e\n\u003cdd\u003eFlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\" \"\u003eGeneral Specifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eDisplay\u003c\/dt\u003e\n\u003cdd\u003e75 x 105 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003ePower\u003c\/dt\u003e\n\u003cdd\u003e12 V lead-acid rechargeable battery, Yuasa NP2.8-12\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eCharger Input (AC)\u003c\/dt\u003e\n\u003cdd\u003e85 V to 250 V AC 50\/60 Hz 20 VA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eDimensions\u003c\/dt\u003e\n\u003cdd\u003e269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eWeight\u003c\/dt\u003e\n\u003cdd\u003e3.7 kg (8.2 lb)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTemperature (operating)\u003c\/dt\u003e\n\u003cdd\u003e-20°C to 50°C (-4°F to 122°F)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eTemperature (storage)\u003c\/dt\u003e\n\u003cdd\u003e-20°C to 65°C (-4°F to 149°F)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eHumidity\u003c\/dt\u003e\n\u003cdd\u003e80% to 31°C decreasing linearly to 50% at 50°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eAltitude\u003c\/dt\u003e\n\u003cdd\u003e2000 m\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eEnclosure sealing\u003c\/dt\u003e\n\u003cdd\u003eIP40\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eInput overload protection\u003c\/dt\u003e\n\u003cdd\u003e1000 V AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eElectromagnetic compatibility\u003c\/dt\u003e\n\u003cdd\u003eEN 61326\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"   \"\u003e\n\u003cdt\u003eSafety compliance\u003c\/dt\u003e\n\u003cdd\u003eIEC 61010-1: Overvoltage category II, Pollution Degree 2.IEC 61010-2-030: Measurement 600V CAT IV \/ 1000V CAT IIIIEC 61557-1, IEC 61557-2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49516972966173,"sku":"DA-1100868","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/dropship-automation_0092e0b7-325d-4ed9-9669-83ffda27b017.webp?v=1735645123","url":"https:\/\/dropshipautomation.com\/products\/fluke-fluke-1550c","provider":"Dropship Automation","version":"1.0","type":"link"}