{"product_id":"eaton-290058","title":"EATON 290058","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e290058\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminal capacity (flexible with ferrule)\u003c\/dt\u003e\n\u003cdd\u003e2 x (0.75 - 2.5) mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current for specified heat dissipation (In)\u003c\/dt\u003e\n\u003cdd\u003e15.5 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.11 Short-circuit rating\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility. The specifications for the switchgear must be observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-3, 380\/400 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e7.5 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConventional thermal current ith (3-pole, enclosed)\u003c\/dt\u003e\n\u003cdd\u003e18 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-4, 380\/400 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e3 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-4, 440 V\u003c\/dt\u003e\n\u003cdd\u003e7 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at AC, 50 Hz - min\u003c\/dt\u003e\n\u003cdd\u003e230 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.4 Clearances and creepage distances\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of contacts (normally closed) as main contact\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit current rating (high fault at 480 V)\u003c\/dt\u003e\n\u003cdd\u003e25 A, Class RK5\/ 60 A Class J, max. Fuse, SCCR (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConventional thermal current ith at 55°C (3-pole, open)\u003c\/dt\u003e\n\u003cdd\u003e21 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power (NEMA)\u003c\/dt\u003e\n\u003cdd\u003e7.4 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.1 Verification of thermal stability of enclosures\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient storage temperature - min\u003c\/dt\u003e\n\u003cdd\u003e40°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated breaking capacity at 380\/400 V\u003c\/dt\u003e\n\u003cdd\u003e124 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit current rating (basic rating)\u003c\/dt\u003e\n\u003cdd\u003e60 A, max. CB, SCCR (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at AC, 50 Hz - max\u003c\/dt\u003e\n\u003cdd\u003e230 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated breaking capacity at 660\/690 V\u003c\/dt\u003e\n\u003cdd\u003e70 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at DC-1, 220 V\u003c\/dt\u003e\n\u003cdd\u003e15 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSpecial purpose rating of elevator control\u003c\/dt\u003e\n\u003cdd\u003e7.8 A, 200 V 60 Hz 3-ph, (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient operating temperature - max\u003c\/dt\u003e\n\u003cdd\u003e60°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 115\/120 V, 60 Hz, 1-phase\u003c\/dt\u003e\n\u003cdd\u003e1 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-4, 440 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e3.6 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectrical connection type of main circuit\u003c\/dt\u003e\n\u003cdd\u003eScrew connection\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber Of Poles\u003c\/dt\u003e\n\u003cdd\u003eThree-pole\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient operating temperature - min\u003c\/dt\u003e\n\u003cdd\u003e-25°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.6 Incorporation of switching devices and components\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.6 Mechanical impact\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.3 Degree of protection of assemblies\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eApplication\u003c\/dt\u003e\n\u003cdd\u003eContactors for Motors\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating frequency\u003c\/dt\u003e\n\u003cdd\u003e5000 mechanical Operations\/h (AC operated)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage type\u003c\/dt\u003e\n\u003cdd\u003eAC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit protection rating (type 1 coordination) at 400 V\u003c\/dt\u003e\n\u003cdd\u003e63 A gG\/gL\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct category\u003c\/dt\u003e\n\u003cdd\u003eContactors\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-4, 220 V, 230 V, 240 V\u003c\/dt\u003e\n\u003cdd\u003e7 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption, pick-up, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e24 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeat dissipation capacity Pdiss\u003c\/dt\u003e\n\u003cdd\u003e0 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 460\/480 V, 60 Hz, 3-phase\u003c\/dt\u003e\n\u003cdd\u003e10 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSpecial purpose rating of tungsten incandescent lamps\u003c\/dt\u003e\n\u003cdd\u003e14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching time (AC operated, make contacts, opening delay) - min\u003c\/dt\u003e\n\u003cdd\u003e9 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eContinuous ampere rating\u003c\/dt\u003e\n\u003cdd\u003e15.5 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-4, 500 V\u003c\/dt\u003e\n\u003cdd\u003e6 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-3, 240 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e4.6 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminal capacity (solid\/stranded AWG)\u003c\/dt\u003e\n\u003cdd\u003eSingle 18 - 10, double 18 - 14\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.2 Power-frequency electric strength\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDegree of protection\u003c\/dt\u003e\n\u003cdd\u003eIP20\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOvervoltage category\u003c\/dt\u003e\n\u003cdd\u003eIII\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching time (AC operated, make contacts, opening delay) - max\u003c\/dt\u003e\n\u003cdd\u003e18 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient storage temperature - max\u003c\/dt\u003e\n\u003cdd\u003e80°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePollution degree\u003c\/dt\u003e\n\u003cdd\u003e3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-1, 380 V, 400 V, 415 V\u003c\/dt\u003e\n\u003cdd\u003e22 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption, pick-up, 60 Hz\u003c\/dt\u003e\n\u003cdd\u003e30 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching time (AC operated, make contacts, closing delay) - max\u003c\/dt\u003e\n\u003cdd\u003e21 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated impulse withstand voltage (Uimp)\u003c\/dt\u003e\n\u003cdd\u003e8000 V AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection\u003c\/dt\u003e\n\u003cdd\u003eScrew connection\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTightening torque\u003c\/dt\u003e\n\u003cdd\u003e1.2 Nm, Screw terminals\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-4, 660\/690 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e4.4 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFrame size\u003c\/dt\u003e\n\u003cdd\u003e45 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConventional thermal current ith (1-pole, enclosed)\u003c\/dt\u003e\n\u003cdd\u003e45 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-3, 660 V, 690 V\u003c\/dt\u003e\n\u003cdd\u003e9 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eType\u003c\/dt\u003e\n\u003cdd\u003eFull voltage non-reversing miniature contactor\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.2 Corrosion resistance\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.4 Resistance to ultra-violet (UV) radiation\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.7 Inscriptions\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-3, 380 V, 400 V, 415 V\u003c\/dt\u003e\n\u003cdd\u003e15.5 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of contacts (normally open contacts)\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching time (AC operated, make contacts, closing delay) - min\u003c\/dt\u003e\n\u003cdd\u003e15 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit protection rating (type 2 coordination) at 400 V\u003c\/dt\u003e\n\u003cdd\u003e20 A gG\/gL\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSpecial purpose rating of ballast electrical discharge lamps\u003c\/dt\u003e\n\u003cdd\u003e20 A (480V 60Hz 3phase, 277V 60Hz 1phase)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of auxiliary contacts (normally open contacts)\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSpecial purpose rating of definite purpose rating\u003c\/dt\u003e\n\u003cdd\u003e90 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShock resistance\u003c\/dt\u003e\n\u003cdd\u003e10 g, N\/O main contact, Mechanical, according to IEC\/EN 60068-2-27, Half-sinusoidal shock 10 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at DC-1, 110 V\u003c\/dt\u003e\n\u003cdd\u003e20 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 230\/240 V, 60 Hz, 3-phase\u003c\/dt\u003e\n\u003cdd\u003e5 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDrop-out voltage\u003c\/dt\u003e\n\u003cdd\u003eAC operated: 0.6 - 0.3 x UC, AC operated\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption, sealing, 60 Hz\u003c\/dt\u003e\n\u003cdd\u003e4.4 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResistance per pole\u003c\/dt\u003e\n\u003cdd\u003e2.5 m©\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient operating temperature (enclosed) - min\u003c\/dt\u003e\n\u003cdd\u003e25°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStripping length (control circuit cable)\u003c\/dt\u003e\n\u003cdd\u003e10 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.12 Electromagnetic compatibility\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility. The specifications for the switchgear must be observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSpecial purpose rating of refrigeration control (CSA only)\u003c\/dt\u003e\n\u003cdd\u003e60 A, LRA 600 V 60 Hz 3phase; (CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmperage Rating\u003c\/dt\u003e\n\u003cdd\u003e170A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.5 Lifting\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStripping length (main cable)\u003c\/dt\u003e\n\u003cdd\u003e10 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient operating temperature (enclosed) - max\u003c\/dt\u003e\n\u003cdd\u003e40°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSpecial purpose rating of resistance air heating\u003c\/dt\u003e\n\u003cdd\u003e20 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at DC - min\u003c\/dt\u003e\n\u003cdd\u003e0 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit current rating (high fault at 600 V)\u003c\/dt\u003e\n\u003cdd\u003e30\/100 kA, Fuse, SCCR (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFrequency rating\u003c\/dt\u003e\n\u003cdd\u003e50-60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.8 Connections for external conductors\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of main contacts (normally open contact)\u003c\/dt\u003e\n\u003cdd\u003e3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated breaking capacity at 220\/230 V\u003c\/dt\u003e\n\u003cdd\u003e124 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eScrew size\u003c\/dt\u003e\n\u003cdd\u003eM3.5, Terminal screw\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-4, 400 V\u003c\/dt\u003e\n\u003cdd\u003e7 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminals\u003c\/dt\u003e\n\u003cdd\u003eScrew terminals\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit protection rating (type 2 coordination) at 690 V\u003c\/dt\u003e\n\u003cdd\u003e20 A gG\/gL\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 575\/600 V, 60 Hz, 3-phase\u003c\/dt\u003e\n\u003cdd\u003e10 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtection\u003c\/dt\u003e\n\u003cdd\u003eFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption, sealing, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e1.4 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHP rating - max\u003c\/dt\u003e\n\u003cdd\u003e1, 3\/ 5, 5, 10, 10 hp (1\/3PH @120, 240\/208, 240, 480 V)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated breaking capacity at 500 V\u003c\/dt\u003e\n\u003cdd\u003e100 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-3, 415 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e8 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eClimatic proofing\u003c\/dt\u003e\n\u003cdd\u003eDamp heat, constant, to IEC 60068-2-78\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEmitted interference\u003c\/dt\u003e\n\u003cdd\u003eAccording to EN 60947-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection to SmartWire-DT\u003c\/dt\u003e\n\u003cdd\u003eNo\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStatic heat dissipation, non-current-dependent Pvs\u003c\/dt\u003e\n\u003cdd\u003e1.4 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at DC - max\u003c\/dt\u003e\n\u003cdd\u003e0 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.3 Impulse withstand voltage\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUtilization category\u003c\/dt\u003e\n\u003cdd\u003eAC-1: Non-inductive or slightly inductive loads, resistance furnaces\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCoil voltage\u003c\/dt\u003e\n\u003cdd\u003e230-240 Vac, 50\/60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-3, 440 V\u003c\/dt\u003e\n\u003cdd\u003e15.5 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.5 Protection against electric shock\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSafe isolation\u003c\/dt\u003e\n\u003cdd\u003e400 V AC, Between coil and contactss, According to EN 61140\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.13 Mechanical function\u003c\/dt\u003e\n\u003cdd\u003eThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.4 Testing of enclosures made of insulating material\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeat dissipation per pole, current-dependent Pvid\u003c\/dt\u003e\n\u003cdd\u003e.5 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching capacity (auxiliary contacts, general use)\u003c\/dt\u003e\n\u003cdd\u003e1 A, 250 V DC, (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating temperature - min\u003c\/dt\u003e\n\u003cdd\u003e-25°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-4, 660 V, 690 V\u003c\/dt\u003e\n\u003cdd\u003e5 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEquipment heat dissipation, current-dependent Pvid\u003c\/dt\u003e\n\u003cdd\u003e0 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 200\/208 V, 60 Hz, 3-phase\u003c\/dt\u003e\n\u003cdd\u003e5 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePick-up voltage\u003c\/dt\u003e\n\u003cdd\u003e0.8 - 1.1 V AC x Uc\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperation\u003c\/dt\u003e\n\u003cdd\u003eReversing\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminal capacity (solid)\u003c\/dt\u003e\n\u003cdd\u003e2 x (0.75 - 2.5) mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of auxiliary contacts (normally closed contacts)\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInterference immunity\u003c\/dt\u003e\n\u003cdd\u003eAccording to EN 60947-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption\u003c\/dt\u003e\n\u003cdd\u003e7.5 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.2 Verification of resistance of insulating materials to normal heat\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating temperature - max\u003c\/dt\u003e\n\u003cdd\u003e60°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.3 Resist. of insul. mat. to abnormal heat\/fire by internal elect. effects\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLifespan, mechanical\u003c\/dt\u003e\n\u003cdd\u003e10,000,000 Operations (AC operated)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit protection rating (type 1 coordination) at 690 V\u003c\/dt\u003e\n\u003cdd\u003e50 A gG\/gL\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated making capacity up to 690 V (cos phi to IEC\/EN 60947)\u003c\/dt\u003e\n\u003cdd\u003e155 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-4, 240 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e2.2 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-4, 500 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e3.5 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage rating\u003c\/dt\u003e\n\u003cdd\u003e400 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of contacts\u003c\/dt\u003e\n\u003cdd\u003e1 NO\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at DC-1, 60 V\u003c\/dt\u003e\n\u003cdd\u003e20 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-4, 220\/230 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e2 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational voltage (Ue) at AC - max\u003c\/dt\u003e\n\u003cdd\u003e690 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at AC, 60 Hz - min\u003c\/dt\u003e\n\u003cdd\u003e240 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.7 Internal electrical circuits and connections\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.10 Temperature rise\u003c\/dt\u003e\n\u003cdd\u003eThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching capacity (main contacts, general use)\u003c\/dt\u003e\n\u003cdd\u003e20 A, Maximum motor rating (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-3, 500 V\u003c\/dt\u003e\n\u003cdd\u003e12.5 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 230\/240 V, 60 Hz, 1-phase\u003c\/dt\u003e\n\u003cdd\u003e3 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eScrewdriver size\u003c\/dt\u003e\n\u003cdd\u003e0.8 x 5.5\/1 x 6 mm, Terminal screw, Standard screwdriver\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDuty factor\u003c\/dt\u003e\n\u003cdd\u003e100 %\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-3, 220 V, 230 V, 240 V\u003c\/dt\u003e\n\u003cdd\u003e15.5 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConventional thermal current ith of main contacts (1-pole, open)\u003c\/dt\u003e\n\u003cdd\u003e50 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at AC, 60 Hz - max\u003c\/dt\u003e\n\u003cdd\u003e240 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eArcing time\u003c\/dt\u003e\n\u003cdd\u003e10 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-4, 415 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e3.4 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching capacity (auxiliary contacts, pilot duty)\u003c\/dt\u003e\n\u003cdd\u003eA600, AC operated (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated insulation voltage (Ui)\u003c\/dt\u003e\n\u003cdd\u003e690 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eGeneral\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eModel Code\u003c\/dt\u003e\n\u003cdd\u003eDILM15-10(230V50HZ,240V60HZ)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEAN\u003c\/dt\u003e\n\u003cdd\u003e4015082900588\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Length\/Depth\u003c\/dt\u003e\n\u003cdd\u003e75 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Height\u003c\/dt\u003e\n\u003cdd\u003e68 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Width\u003c\/dt\u003e\n\u003cdd\u003e45 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Weight\u003c\/dt\u003e\n\u003cdd\u003e.24 kg\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWarranty\u003c\/dt\u003e\n\u003cdd\u003e1 year\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCompliances\u003c\/dt\u003e\n\u003cdd\u003eCE Marked\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCertifications\u003c\/dt\u003e\n\u003cdd\u003eUL Listed\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCatalog Notes\u003c\/dt\u003e\n\u003cdd\u003eContacts according to EN 50012|Not suitable for motors with efficiency class IE3.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49108022559005,"sku":"DA-492444","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/eaton-290058-dropship-automation.webp?v=1754312480","url":"https:\/\/dropshipautomation.com\/products\/eaton-290058","provider":"Dropship Automation","version":"1.0","type":"link"}