{"product_id":"eaton-277766","title":"EATON 277766","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e277766\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminal capacity (flexible with ferrule)\u003c\/dt\u003e\n\u003cdd\u003e2 x (0.75 - 2.5) mm², Control circuit cables\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current for specified heat dissipation (In)\u003c\/dt\u003e\n\u003cdd\u003e40 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.11 Short-circuit rating\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility. The specifications for the switchgear must be observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-3, 380\/400 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e18.5 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConventional thermal current ith (3-pole, enclosed)\u003c\/dt\u003e\n\u003cdd\u003e45 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-4, 380\/400 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e9 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-4, 440 V\u003c\/dt\u003e\n\u003cdd\u003e18 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminal capacity (copper band)\u003c\/dt\u003e\n\u003cdd\u003e2 x (6 x 9 x 0.8) mm (Number of segments x width x thickness), Main cables\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at AC, 50 Hz - min\u003c\/dt\u003e\n\u003cdd\u003e230 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.4 Clearances and creepage distances\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of contacts (normally closed) as main contact\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit current rating (high fault at 480 V)\u003c\/dt\u003e\n\u003cdd\u003e250\/150 A, Class J, max. Fuse, SCCR (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConventional thermal current ith at 55°C (3-pole, open)\u003c\/dt\u003e\n\u003cdd\u003e55 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power (NEMA)\u003c\/dt\u003e\n\u003cdd\u003e22 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.1 Verification of thermal stability of enclosures\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient storage temperature - min\u003c\/dt\u003e\n\u003cdd\u003e40°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated breaking capacity at 380\/400 V\u003c\/dt\u003e\n\u003cdd\u003e400 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit current rating (basic rating)\u003c\/dt\u003e\n\u003cdd\u003e10 kA, SCCR (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at AC, 50 Hz - max\u003c\/dt\u003e\n\u003cdd\u003e230 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated breaking capacity at 660\/690 V\u003c\/dt\u003e\n\u003cdd\u003e250 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at DC-1, 220 V\u003c\/dt\u003e\n\u003cdd\u003e45 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSpecial purpose rating of elevator control\u003c\/dt\u003e\n\u003cdd\u003e10 HP, 240 V 60 Hz 3-ph, (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient operating temperature - max\u003c\/dt\u003e\n\u003cdd\u003e60°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 115\/120 V, 60 Hz, 1-phase\u003c\/dt\u003e\n\u003cdd\u003e3 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-4, 440 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e10 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectrical connection type of main circuit\u003c\/dt\u003e\n\u003cdd\u003eScrew connection\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber Of Poles\u003c\/dt\u003e\n\u003cdd\u003eThree-pole\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient operating temperature - min\u003c\/dt\u003e\n\u003cdd\u003e-25°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.6 Incorporation of switching devices and components\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.6 Mechanical impact\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.3 Degree of protection of assemblies\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eApplication\u003c\/dt\u003e\n\u003cdd\u003eContactors for Motors\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating frequency\u003c\/dt\u003e\n\u003cdd\u003e5000 mechanical Operations\/h (AC operated)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage type\u003c\/dt\u003e\n\u003cdd\u003eAC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit protection rating (type 1 coordination) at 400 V\u003c\/dt\u003e\n\u003cdd\u003e125 A gG\/gL\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct category\u003c\/dt\u003e\n\u003cdd\u003eContactors\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-4, 220 V, 230 V, 240 V\u003c\/dt\u003e\n\u003cdd\u003e18 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption, pick-up, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e149 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeat dissipation capacity Pdiss\u003c\/dt\u003e\n\u003cdd\u003e0 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 460\/480 V, 60 Hz, 3-phase\u003c\/dt\u003e\n\u003cdd\u003e30 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSpecial purpose rating of tungsten incandescent lamps\u003c\/dt\u003e\n\u003cdd\u003e74 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching time (AC operated, make contacts, opening delay) - min\u003c\/dt\u003e\n\u003cdd\u003e8 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eContinuous ampere rating\u003c\/dt\u003e\n\u003cdd\u003e63 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-4, 500 V\u003c\/dt\u003e\n\u003cdd\u003e18 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-3, 240 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e13.5 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminal capacity (solid\/stranded AWG)\u003c\/dt\u003e\n\u003cdd\u003eSingle 14 - 1, double 14 - 2, Main cables\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.2 Power-frequency electric strength\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDegree of protection\u003c\/dt\u003e\n\u003cdd\u003eIP00\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOvervoltage category\u003c\/dt\u003e\n\u003cdd\u003eIII\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching time (AC operated, make contacts, opening delay) - max\u003c\/dt\u003e\n\u003cdd\u003e13 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient storage temperature - max\u003c\/dt\u003e\n\u003cdd\u003e80°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePollution degree\u003c\/dt\u003e\n\u003cdd\u003e3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-1, 380 V, 400 V, 415 V\u003c\/dt\u003e\n\u003cdd\u003e60 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption, pick-up, 60 Hz\u003c\/dt\u003e\n\u003cdd\u003e178 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching time (AC operated, make contacts, closing delay) - max\u003c\/dt\u003e\n\u003cdd\u003e18 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated impulse withstand voltage (Uimp)\u003c\/dt\u003e\n\u003cdd\u003e8000 V AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection\u003c\/dt\u003e\n\u003cdd\u003eSpring-loaded\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTightening torque\u003c\/dt\u003e\n\u003cdd\u003e1.2 Nm, Screw terminals, Control circuit cables\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-4, 660\/690 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e12 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConventional thermal current ith (1-pole, enclosed)\u003c\/dt\u003e\n\u003cdd\u003e112 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-3, 660 V, 690 V\u003c\/dt\u003e\n\u003cdd\u003e25 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eType\u003c\/dt\u003e\n\u003cdd\u003eFull voltage non-reversing contactor\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.2 Corrosion resistance\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.4 Resistance to ultra-violet (UV) radiation\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.7 Inscriptions\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-3, 380 V, 400 V, 415 V\u003c\/dt\u003e\n\u003cdd\u003e40 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching time (AC operated, make contacts, closing delay) - min\u003c\/dt\u003e\n\u003cdd\u003e12 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit protection rating (type 2 coordination) at 400 V\u003c\/dt\u003e\n\u003cdd\u003e63 A gG\/gL\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSpecial purpose rating of ballast electrical discharge lamps\u003c\/dt\u003e\n\u003cdd\u003e79 A (480V 60Hz 3phase, 277V 60Hz 1phase)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of auxiliary contacts (normally open contacts)\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShock resistance\u003c\/dt\u003e\n\u003cdd\u003e5 g, N\/C auxiliary contact, Mechanical, according to IEC\/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at DC-1, 110 V\u003c\/dt\u003e\n\u003cdd\u003e50 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 230\/240 V, 60 Hz, 3-phase\u003c\/dt\u003e\n\u003cdd\u003e15 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDrop-out voltage\u003c\/dt\u003e\n\u003cdd\u003eAC operated: 0.6 - 0.3 x UC, AC operated\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption, sealing, 60 Hz\u003c\/dt\u003e\n\u003cdd\u003e4.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResistance per pole\u003c\/dt\u003e\n\u003cdd\u003e1.9 mΩ\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient operating temperature (enclosed) - min\u003c\/dt\u003e\n\u003cdd\u003e25°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStripping length (control circuit cable)\u003c\/dt\u003e\n\u003cdd\u003e10 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.12 Electromagnetic compatibility\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility. The specifications for the switchgear must be observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmperage Rating\u003c\/dt\u003e\n\u003cdd\u003e170A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.5 Lifting\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStripping length (main cable)\u003c\/dt\u003e\n\u003cdd\u003e14 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient operating temperature (enclosed) - max\u003c\/dt\u003e\n\u003cdd\u003e40°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSpecial purpose rating of resistance air heating\u003c\/dt\u003e\n\u003cdd\u003e79 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at DC - min\u003c\/dt\u003e\n\u003cdd\u003e0 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit current rating (high fault at 600 V)\u003c\/dt\u003e\n\u003cdd\u003e250 A, max. CB, SCCR (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFrequency rating\u003c\/dt\u003e\n\u003cdd\u003e50-60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.8 Connections for external conductors\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of main contacts (normally open contact)\u003c\/dt\u003e\n\u003cdd\u003e3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated breaking capacity at 220\/230 V\u003c\/dt\u003e\n\u003cdd\u003e400 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eScrew size\u003c\/dt\u003e\n\u003cdd\u003eM6, Terminal screw, Main cables\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-4, 400 V\u003c\/dt\u003e\n\u003cdd\u003e18 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminals\u003c\/dt\u003e\n\u003cdd\u003eSpring loaded terminals\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit protection rating (type 2 coordination) at 690 V\u003c\/dt\u003e\n\u003cdd\u003e50 A gG\/gL\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 575\/600 V, 60 Hz, 3-phase\u003c\/dt\u003e\n\u003cdd\u003e40 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtection\u003c\/dt\u003e\n\u003cdd\u003eFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption, sealing, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e16 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminal capacity (stranded)\u003c\/dt\u003e\n\u003cdd\u003e1 x (16 - 50) mm², Main cables\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHP rating - max\u003c\/dt\u003e\n\u003cdd\u003e3, 7.5\/ 10, 15, 30, 40 hp (1\/3PH @120, 240\/ 208, 240, 480, 600 V)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated breaking capacity at 500 V\u003c\/dt\u003e\n\u003cdd\u003e400 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-3, 415 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e24 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eClimatic proofing\u003c\/dt\u003e\n\u003cdd\u003eDamp heat, constant, to IEC 60068-2-78\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEmitted interference\u003c\/dt\u003e\n\u003cdd\u003eAccording to EN 60947-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection to SmartWire-DT\u003c\/dt\u003e\n\u003cdd\u003eNo\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStatic heat dissipation, non-current-dependent Pvs\u003c\/dt\u003e\n\u003cdd\u003e4.1 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at DC - max\u003c\/dt\u003e\n\u003cdd\u003e0 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.3 Impulse withstand voltage\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUtilization category\u003c\/dt\u003e\n\u003cdd\u003eAC-3: Normal AC induction motors: starting, switch off during running\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCoil voltage\u003c\/dt\u003e\n\u003cdd\u003e230-240 Vac, 50\/60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-3, 440 V\u003c\/dt\u003e\n\u003cdd\u003e40 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.5 Protection against electric shock\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSafe isolation\u003c\/dt\u003e\n\u003cdd\u003e440 V AC, Between the contacts, According to EN 61140\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.13 Mechanical function\u003c\/dt\u003e\n\u003cdd\u003eThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.4 Testing of enclosures made of insulating material\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeat dissipation per pole, current-dependent Pvid\u003c\/dt\u003e\n\u003cdd\u003e2.2 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating temperature - min\u003c\/dt\u003e\n\u003cdd\u003e-25°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-4, 660 V, 690 V\u003c\/dt\u003e\n\u003cdd\u003e14 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEquipment heat dissipation, current-dependent Pvid\u003c\/dt\u003e\n\u003cdd\u003e6.6 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 200\/208 V, 60 Hz, 3-phase\u003c\/dt\u003e\n\u003cdd\u003e10 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePick-up voltage\u003c\/dt\u003e\n\u003cdd\u003e0.8 - 1.1 V AC x Uc\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSuitable for\u003c\/dt\u003e\n\u003cdd\u003eAlso motors with efficiency class IE3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperation\u003c\/dt\u003e\n\u003cdd\u003eNon-reversing\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminal capacity (solid)\u003c\/dt\u003e\n\u003cdd\u003e1 x (0.75 - 16) mm², Main cables\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of auxiliary contacts (normally closed contacts)\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eInterference immunity\u003c\/dt\u003e\n\u003cdd\u003eAccording to EN 60947-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption\u003c\/dt\u003e\n\u003cdd\u003e18 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.2 Verification of resistance of insulating materials to normal heat\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating temperature - max\u003c\/dt\u003e\n\u003cdd\u003e60°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.3 Resist. of insul. mat. to abnormal heat\/fire by internal elect. effects\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLifespan, mechanical\u003c\/dt\u003e\n\u003cdd\u003e10,000,000 Operations (AC operated)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit protection rating (type 1 coordination) at 690 V\u003c\/dt\u003e\n\u003cdd\u003e80 A gG\/gL\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated making capacity up to 690 V (cos phi to IEC\/EN 60947)\u003c\/dt\u003e\n\u003cdd\u003e560 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-4, 240 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e5.5 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-4, 500 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e11 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage rating\u003c\/dt\u003e\n\u003cdd\u003e400 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at DC-1, 60 V\u003c\/dt\u003e\n\u003cdd\u003e50 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-4, 220\/230 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e5 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational voltage (Ue) at AC - max\u003c\/dt\u003e\n\u003cdd\u003e690 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at AC, 60 Hz - min\u003c\/dt\u003e\n\u003cdd\u003e240 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.7 Internal electrical circuits and connections\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.10 Temperature rise\u003c\/dt\u003e\n\u003cdd\u003eThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching capacity (main contacts, general use)\u003c\/dt\u003e\n\u003cdd\u003e63 A, Maximum motor rating (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-3, 500 V\u003c\/dt\u003e\n\u003cdd\u003e40 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 230\/240 V, 60 Hz, 1-phase\u003c\/dt\u003e\n\u003cdd\u003e7.5 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eScrewdriver size\u003c\/dt\u003e\n\u003cdd\u003e2, Terminal screw, Pozidriv screwdriver\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDuty factor\u003c\/dt\u003e\n\u003cdd\u003e100 %\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-3, 220 V, 230 V, 240 V\u003c\/dt\u003e\n\u003cdd\u003e40 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConventional thermal current ith of main contacts (1-pole, open)\u003c\/dt\u003e\n\u003cdd\u003e125 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at AC, 60 Hz - max\u003c\/dt\u003e\n\u003cdd\u003e240 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eArcing time\u003c\/dt\u003e\n\u003cdd\u003e10 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-4, 415 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e9.5 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated insulation voltage (Ui)\u003c\/dt\u003e\n\u003cdd\u003e690 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eGeneral\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eModel Code\u003c\/dt\u003e\n\u003cdd\u003eDILM40(230V50HZ,240V60HZ)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEAN\u003c\/dt\u003e\n\u003cdd\u003e4015082777661\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Length\/Depth\u003c\/dt\u003e\n\u003cdd\u003e132.1 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Height\u003c\/dt\u003e\n\u003cdd\u003e115 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Width\u003c\/dt\u003e\n\u003cdd\u003e55 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Weight\u003c\/dt\u003e\n\u003cdd\u003e.872 kg\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWarranty\u003c\/dt\u003e\n\u003cdd\u003eNot Applicable\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCompliances\u003c\/dt\u003e\n\u003cdd\u003eCE Marked\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCertifications\u003c\/dt\u003e\n\u003cdd\u003eIEC 60947-4-1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCatalog Notes\u003c\/dt\u003e\n\u003cdd\u003eContacts according to EN 50012|IE3-ready devices are identified by the logo on their packaging.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":48970175021341,"sku":"DA-7581","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/eaton-277766-dropship-automation.webp?v=1752245109","url":"https:\/\/dropshipautomation.com\/products\/eaton-277766","provider":"Dropship Automation","version":"1.0","type":"link"}