{"product_id":"eaton-259622","title":"EATON 259622","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e259622\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.11 Short-circuit rating\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility. The specifications for the switchgear must be observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at AC, 50 Hz - min\u003c\/dt\u003e\n\u003cdd\u003e208 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.4 Clearances and creepage distances\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMinimum command time - min\u003c\/dt\u003e\n\u003cdd\u003e10 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.12 Electromagnetic compatibility\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility. The specifications for the switchgear must be observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.5 Lifting\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePick-up power consumption at AC (undervoltage release)\u003c\/dt\u003e\n\u003cdd\u003e1.5 VA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.1 Verification of thermal stability of enclosures\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at DC - min\u003c\/dt\u003e\n\u003cdd\u003e0 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFitted with:\u003c\/dt\u003e\n\u003cdd\u003eTwo separate early-make auxiliary contacts\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePick-up power consumption at DC (undervoltage release)\u003c\/dt\u003e\n\u003cdd\u003e.8 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at AC, 50 Hz - max\u003c\/dt\u003e\n\u003cdd\u003e240 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.8 Connections for external conductors\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMinimum command time - max\u003c\/dt\u003e\n\u003cdd\u003e15 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSpecial features\u003c\/dt\u003e\n\u003cdd\u003eUndervoltage release with 2 early-make auxiliary contacts, e.g., for early-make connection of undervoltage release in main switch applications, as well as for interlock and load shedding circuits.|For use with emergency-stop devices in connection with an emergency-stop button.|When the under-voltage trip is switched off, accidental contact with the circuit breaker™s primary contacts is prevented when switched on.|Early make of auxiliary contacts on switching on and off (manual operation): approx. 20 ms|Cannot be used in conjunction with NZM...-XR... remote operator.|Undervoltage releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XA... shunt release.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at DC - max\u003c\/dt\u003e\n\u003cdd\u003e0 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.3 Impulse withstand voltage\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage\u003c\/dt\u003e\n\u003cdd\u003e208 - 240 V 50\/60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.6 Incorporation of switching devices and components\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.5 Protection against electric shock\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUsed with\u003c\/dt\u003e\n\u003cdd\u003eNZM1(-4), N(S)1(-4)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectric connection type\u003c\/dt\u003e\n\u003cdd\u003eScrew connection\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.13 Mechanical function\u003c\/dt\u003e\n\u003cdd\u003eThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.6 Mechanical impact\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.4 Testing of enclosures made of insulating material\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.3 Degree of protection of assemblies\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage type\u003c\/dt\u003e\n\u003cdd\u003eAC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDrop-out voltage of undervoltage release AC\/DC - min\u003c\/dt\u003e\n\u003cdd\u003e0.35 x Us\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFrame\u003c\/dt\u003e\n\u003cdd\u003eNZM1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eReaction time\u003c\/dt\u003e\n\u003cdd\u003e19 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSuitable for\u003c\/dt\u003e\n\u003cdd\u003eOff-load switch\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage tolerance - min\u003c\/dt\u003e\n\u003cdd\u003e.85\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control voltage (relay contacts)\u003c\/dt\u003e\n\u003cdd\u003e208 V AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower consumption\u003c\/dt\u003e\n\u003cdd\u003e0.8 W (sealing DC)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.2 Verification of resistance of insulating materials to normal heat\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDrop-out voltage of undervoltage release AC\/DC - max\u003c\/dt\u003e\n\u003cdd\u003e0.7 x Us\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.3 Resist. of insul. mat. to abnormal heat\/fire by internal elect. effects\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection type\u003c\/dt\u003e\n\u003cdd\u003eWith 3 m connection cable instead of screw termination\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.2 Power-frequency electric strength\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage tolerance - max\u003c\/dt\u003e\n\u003cdd\u003e1.1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at AC, 60 Hz - min\u003c\/dt\u003e\n\u003cdd\u003e208 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.7 Internal electrical circuits and connections\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminal capacity (solid\/flexible conductor)\u003c\/dt\u003e\n\u003cdd\u003e0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.10 Temperature rise\u003c\/dt\u003e\n\u003cdd\u003eThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eType\u003c\/dt\u003e\n\u003cdd\u003eAccessory|Undervoltage release|Undervoltage release with early-make auxiliary contact\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.2 Corrosion resistance\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.4 Resistance to ultra-violet (UV) radiation\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.7 Inscriptions\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated control supply voltage (Us) at AC, 60 Hz - max\u003c\/dt\u003e\n\u003cdd\u003e240 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of contacts (normally open contacts)\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eGeneral\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eModel Code\u003c\/dt\u003e\n\u003cdd\u003eNZM1-XUHIV20L208-240AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEAN\u003c\/dt\u003e\n\u003cdd\u003e4015082596224\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Length\/Depth\u003c\/dt\u003e\n\u003cdd\u003e37 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Height\u003c\/dt\u003e\n\u003cdd\u003e66 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Width\u003c\/dt\u003e\n\u003cdd\u003e32 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Weight\u003c\/dt\u003e\n\u003cdd\u003e.169 kg\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWarranty\u003c\/dt\u003e\n\u003cdd\u003eEaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCompliances\u003c\/dt\u003e\n\u003cdd\u003eUL\/CSA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCertifications\u003c\/dt\u003e\n\u003cdd\u003eUL (File No. E140305)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49101775962397,"sku":"DA-456920","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/eaton-259622-dropship-automation.webp?v=1754140999","url":"https:\/\/dropshipautomation.com\/products\/eaton-259622","provider":"Dropship Automation","version":"1.0","type":"link"}