{"product_id":"eaton-255907","title":"EATON 255907","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e255907\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current for specified heat dissipation (In)\u003c\/dt\u003e\n\u003cdd\u003e100 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.11 Short-circuit rating\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility. The specifications for the switchgear must be observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at DC-23A, 24 V\u003c\/dt\u003e\n\u003cdd\u003e50 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-3, 380\/400 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e37 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.4 Clearances and creepage distances\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting method\u003c\/dt\u003e\n\u003cdd\u003eSurface mounting\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated breaking capacity at 220\/230 V (cos phi to IEC 60947-3)\u003c\/dt\u003e\n\u003cdd\u003e760 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.1 Verification of thermal stability of enclosures\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFitted with:\u003c\/dt\u003e\n\u003cdd\u003eRed rotary handle and yellow locking ring\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDegree of protection (front side)\u003c\/dt\u003e\n\u003cdd\u003eIP65\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit current rating (basic rating)\u003c\/dt\u003e\n\u003cdd\u003e10 kA, SCCR (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at DC-23A, 120 V\u003c\/dt\u003e\n\u003cdd\u003e25 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated conditional short-circuit current (Iq)\u003c\/dt\u003e\n\u003cdd\u003e4 kA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eActuator type\u003c\/dt\u003e\n\u003cdd\u003eDoor coupling rotary drive\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated making capacity up to 690 V (cos phi to IEC\/EN 60947-3)\u003c\/dt\u003e\n\u003cdd\u003e950 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient operating temperature - max\u003c\/dt\u003e\n\u003cdd\u003e40°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 115\/120 V, 60 Hz, 1-phase\u003c\/dt\u003e\n\u003cdd\u003e5 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFeatures\u003c\/dt\u003e\n\u003cdd\u003eVersion as maintenance-\/service switch\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eElectrical connection type of main circuit\u003c\/dt\u003e\n\u003cdd\u003eScrew connection\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated breaking capacity at 500 V (cos phi to IEC 60947-3)\u003c\/dt\u003e\n\u003cdd\u003e880 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of poles\u003c\/dt\u003e\n\u003cdd\u003eThree-pole\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient operating temperature - min\u003c\/dt\u003e\n\u003cdd\u003e-25°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.6 Incorporation of switching devices and components\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated uninterrupted current (Iu)\u003c\/dt\u003e\n\u003cdd\u003e100 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.6 Mechanical impact\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.3 Degree of protection of assemblies\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating frequency\u003c\/dt\u003e\n\u003cdd\u003e1200 Operations\/h\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Category\u003c\/dt\u003e\n\u003cdd\u003eMain switch\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of contacts in series at DC-23A, 48 V\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at DC-23A, 48 V\u003c\/dt\u003e\n\u003cdd\u003e50 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminal capacity\u003c\/dt\u003e\n\u003cdd\u003e1 x (1.5 - 25) mm², flexible with ferrules to DIN 46228\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of contacts in series at DC-23A, 24 V\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeat dissipation capacity Pdiss\u003c\/dt\u003e\n\u003cdd\u003e0 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 460\/480 V, 60 Hz, 3-phase\u003c\/dt\u003e\n\u003cdd\u003e60 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 200\/208 V, 60 Hz, 1-phase\u003c\/dt\u003e\n\u003cdd\u003e10 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-23A, 400 V, 415 V\u003c\/dt\u003e\n\u003cdd\u003e100 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.2 Power-frequency electric strength\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOvervoltage category\u003c\/dt\u003e\n\u003cdd\u003eIII\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDegree of protection\u003c\/dt\u003e\n\u003cdd\u003eIP65\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eActuator color\u003c\/dt\u003e\n\u003cdd\u003eRed\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-23A, 230 V\u003c\/dt\u003e\n\u003cdd\u003e100 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePollution degree\u003c\/dt\u003e\n\u003cdd\u003e3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-23A, 500 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e55 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated impulse withstand voltage (Uimp)\u003c\/dt\u003e\n\u003cdd\u003e6000 V AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching power at 400 V\u003c\/dt\u003e\n\u003cdd\u003e55 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage per contact pair in series\u003c\/dt\u003e\n\u003cdd\u003e60 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFunctions\u003c\/dt\u003e\n\u003cdd\u003eInterlockable\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTightening torque\u003c\/dt\u003e\n\u003cdd\u003e3 Nm, Screw terminals\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-3, 690 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e37 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-3, 660 V, 690 V\u003c\/dt\u003e\n\u003cdd\u003e23.8 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eType\u003c\/dt\u003e\n\u003cdd\u003eMain switch\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.2 Corrosion resistance\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.4 Resistance to ultra-violet (UV) radiation\u003c\/dt\u003e\n\u003cdd\u003eUV resistance only in connection with protective shield.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.7 Inscriptions\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-3, 380 V, 400 V, 415 V\u003c\/dt\u003e\n\u003cdd\u003e71 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of auxiliary contacts (normally open contacts)\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShock resistance\u003c\/dt\u003e\n\u003cdd\u003e15 g, Mechanical, According to IEC\/EN 60068-2-27, Half-sinusoidal shock 20 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 230\/240 V, 60 Hz, 3-phase\u003c\/dt\u003e\n\u003cdd\u003e25 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient operating temperature (enclosed) - min\u003c\/dt\u003e\n\u003cdd\u003e-25°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-23A, 400 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e55 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-23A, 500 V\u003c\/dt\u003e\n\u003cdd\u003e96 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at DC-23A, 60 V\u003c\/dt\u003e\n\u003cdd\u003e50 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-23A, 220\/230 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e30 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.12 Electromagnetic compatibility\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility. The specifications for the switchgear must be observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.5 Lifting\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient operating temperature (enclosed) - max\u003c\/dt\u003e\n\u003cdd\u003e40°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-21, 440 V\u003c\/dt\u003e\n\u003cdd\u003e100 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational voltage (Ue) at AC - min\u003c\/dt\u003e\n\u003cdd\u003e690 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.8 Connections for external conductors\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eScrew size\u003c\/dt\u003e\n\u003cdd\u003eM5, Terminal screw\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 575\/600 V, 60 Hz, 3-phase\u003c\/dt\u003e\n\u003cdd\u003e75 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLoad rating\u003c\/dt\u003e\n\u003cdd\u003e1.3 x I‚‘ (with intermittent operation class 12, 60 % duty factor)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-23A, 690 V\u003c\/dt\u003e\n\u003cdd\u003e68 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated permanent current at AC-21, 400 V\u003c\/dt\u003e\n\u003cdd\u003e100 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-3, 415 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e37 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eClimatic proofing\u003c\/dt\u003e\n\u003cdd\u003eDamp heat, cyclic, to IEC 60068-2-30\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDevice construction\u003c\/dt\u003e\n\u003cdd\u003eComplete device in housing\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated breaking capacity at 400\/415 V (cos phi to IEC 60947-3)\u003c\/dt\u003e\n\u003cdd\u003e740 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStatic heat dissipation, non-current-dependent Pvs\u003c\/dt\u003e\n\u003cdd\u003e0 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.3 Impulse withstand voltage\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.5 Protection against electric shock\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSafe isolation\u003c\/dt\u003e\n\u003cdd\u003e440 V AC, Between the contacts, According to EN 61140\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMounting position\u003c\/dt\u003e\n\u003cdd\u003eAs required\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSafety parameter (EN ISO 13849-1)\u003c\/dt\u003e\n\u003cdd\u003eB10d values as per EN ISO 13849-1, table C.1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.13 Mechanical function\u003c\/dt\u003e\n\u003cdd\u003eThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power at AC-23A, 690 V, 50 Hz\u003c\/dt\u003e\n\u003cdd\u003e55 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.4 Testing of enclosures made of insulating material\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeat dissipation per pole, current-dependent Pvid\u003c\/dt\u003e\n\u003cdd\u003e7.5 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching capacity (auxiliary contacts, general use)\u003c\/dt\u003e\n\u003cdd\u003e10A, IU, (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUninterrupted current\u003c\/dt\u003e\n\u003cdd\u003eRated uninterrupted current Iu is specified for max. cross-section.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEquipment heat dissipation, current-dependent Pvid\u003c\/dt\u003e\n\u003cdd\u003e0 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 200\/208 V, 60 Hz, 3-phase\u003c\/dt\u003e\n\u003cdd\u003e20 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSuitable for\u003c\/dt\u003e\n\u003cdd\u003eGround mounting\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated breaking capacity at 660\/690 V (cos phi to IEC 60947-3)\u003c\/dt\u003e\n\u003cdd\u003e520 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAccessories\u003c\/dt\u003e\n\u003cdd\u003eAuxiliary contact or neutral conductor fitted by user.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of auxiliary contacts (normally closed contacts)\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at DC-1, load-break switches l\/r = 1 ms\u003c\/dt\u003e\n\u003cdd\u003e100 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.2 Verification of resistance of insulating materials to normal heat\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.3 Resist. of insul. mat. to abnormal heat\/fire by internal elect. effects\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLifespan, mechanical\u003c\/dt\u003e\n\u003cdd\u003e100,000 Operations\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of contacts in series at DC-23A, 60 V\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eControl circuit reliability\u003c\/dt\u003e\n\u003cdd\u003e1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated short-time withstand current (Icw)\u003c\/dt\u003e\n\u003cdd\u003e2 kA, Contacts, 1 second\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of auxiliary contacts (change-over contacts)\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational voltage (Ue) at AC - max\u003c\/dt\u003e\n\u003cdd\u003e690 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.7 Internal electrical circuits and connections\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.10 Temperature rise\u003c\/dt\u003e\n\u003cdd\u003eThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching capacity (main contacts, general use)\u003c\/dt\u003e\n\u003cdd\u003e100 A, If used with neutral conductor IU = max. 90 A, Rated uninterrupted current max. (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of contacts in series at DC-23A, 120 V\u003c\/dt\u003e\n\u003cdd\u003e3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-3, 500 V\u003c\/dt\u003e\n\u003cdd\u003e65 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAssigned motor power at 230\/240 V, 60 Hz, 1-phase\u003c\/dt\u003e\n\u003cdd\u003e15 HP\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current (Ie) at AC-3, 220 V, 230 V, 240 V\u003c\/dt\u003e\n\u003cdd\u003e71 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-circuit protection rating\u003c\/dt\u003e\n\u003cdd\u003e100 A gG\/gL, Fuse, Contacts\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSwitching capacity (auxiliary contacts, pilot duty)\u003c\/dt\u003e\n\u003cdd\u003eA600 (UL\/CSA)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eGeneral\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eModel Code\u003c\/dt\u003e\n\u003cdd\u003eP3-100\/I5\/SVB\/HI11-NA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEAN\u003c\/dt\u003e\n\u003cdd\u003e4015082559076\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Length\/Depth\u003c\/dt\u003e\n\u003cdd\u003e169 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Height\u003c\/dt\u003e\n\u003cdd\u003e280 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Width\u003c\/dt\u003e\n\u003cdd\u003e200 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Weight\u003c\/dt\u003e\n\u003cdd\u003e1.54 kg\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWarranty\u003c\/dt\u003e\n\u003cdd\u003eEaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCertifications\u003c\/dt\u003e\n\u003cdd\u003eUL Listed\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCatalog Notes\u003c\/dt\u003e\n\u003cdd\u003eRated Short-time Withstand Current (Icw) for a time of 1 second|UL\/CSA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49131979604253,"sku":"DA-609033","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/dropship-automation_bb2dc103-953f-49e7-b4ea-2cc3e99fa547.webp?v=1732611990","url":"https:\/\/dropshipautomation.com\/products\/eaton-255907","provider":"Dropship Automation","version":"1.0","type":"link"}