{"product_id":"eaton-236217","title":"EATON 236217","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e236217\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSpecifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational current for specified heat dissipation (In)\u003c\/dt\u003e\n\u003cdd\u003e16 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.11 Short-circuit rating\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility. The specifications for the switchgear must be observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated switching capacity (IEC\/EN 61009)\u003c\/dt\u003e\n\u003cdd\u003e10 kA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.4 Clearances and creepage distances\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.12 Electromagnetic compatibility\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility. The specifications for the switchgear must be observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCurrent limiting class\u003c\/dt\u003e\n\u003cdd\u003e3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmperage Rating\u003c\/dt\u003e\n\u003cdd\u003e16 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.5 Lifting\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.1 Verification of thermal stability of enclosures\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated short-circuit breaking capacity (EN 60947-2)\u003c\/dt\u003e\n\u003cdd\u003e0 kA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFrequency rating\u003c\/dt\u003e\n\u003cdd\u003e50 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.8 Connections for external conductors\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of poles (total)\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFault current rating\u003c\/dt\u003e\n\u003cdd\u003e.03 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSensitivity type\u003c\/dt\u003e\n\u003cdd\u003eType A, pulse-current sensitive\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeat dissipation per pole, current-dependent\u003c\/dt\u003e\n\u003cdd\u003e0 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eBuilt-in depth\u003c\/dt\u003e\n\u003cdd\u003e70 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFeatures\u003c\/dt\u003e\n\u003cdd\u003eConcurrently switching N-neutral\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnectable conductor cross section (solid-core) - min\u003c\/dt\u003e\n\u003cdd\u003e1 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.3 Impulse withstand voltage\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of poles\u003c\/dt\u003e\n\u003cdd\u003eSingle-pole + N\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.6 Incorporation of switching devices and components\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.5 Protection against electric shock\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated switching capacity\u003c\/dt\u003e\n\u003cdd\u003e10 kA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEquipment heat dissipation, current-dependent\u003c\/dt\u003e\n\u003cdd\u003e3.2 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTripping characteristic\u003c\/dt\u003e\n\u003cdd\u003eC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eClass\u003c\/dt\u003e\n\u003cdd\u003eClass 3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.13 Mechanical function\u003c\/dt\u003e\n\u003cdd\u003eThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.6 Mechanical impact\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.4 Testing of enclosures made of insulating material\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eStatic heat dissipation, non-current-dependent\u003c\/dt\u003e\n\u003cdd\u003e0 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eApplication\u003c\/dt\u003e\n\u003cdd\u003eSwitchgear for residential and commercial applications\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.3 Degree of protection of assemblies\u003c\/dt\u003e\n\u003cdd\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage type\u003c\/dt\u003e\n\u003cdd\u003eAC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of poles (protected)\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eLeakage current type\u003c\/dt\u003e\n\u003cdd\u003eA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTripping\u003c\/dt\u003e\n\u003cdd\u003eNon-delayed\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating ambient temperature - min\u003c\/dt\u003e\n\u003cdd\u003e-25°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHeat dissipation capacity\u003c\/dt\u003e\n\u003cdd\u003e0 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRelease characteristic\u003c\/dt\u003e\n\u003cdd\u003eC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eImpulse withstand current\u003c\/dt\u003e\n\u003cdd\u003ePartly surge-proof, 250 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct range\u003c\/dt\u003e\n\u003cdd\u003ePKNM\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWidth in number of modular spacings\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.2 Verification of resistance of insulating materials to normal heat\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.3.3 Resist. of insul. mat. to abnormal heat\/fire by internal elect. effects\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated short-circuit breaking capacity (EN 61009)\u003c\/dt\u003e\n\u003cdd\u003e10 kA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperating ambient temperature - max\u003c\/dt\u003e\n\u003cdd\u003e40°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage rating\u003c\/dt\u003e\n\u003cdd\u003e230 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.9.2 Power-frequency electric strength\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnectable conductor cross section (solid-core) - max\u003c\/dt\u003e\n\u003cdd\u003e25 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDegree of protection\u003c\/dt\u003e\n\u003cdd\u003eIP20\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOvervoltage category\u003c\/dt\u003e\n\u003cdd\u003eIII\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePollution degree\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.7 Internal electrical circuits and connections\u003c\/dt\u003e\n\u003cdd\u003eIs the panel builder's responsibility.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnectable conductor cross section (multi-wired) - min\u003c\/dt\u003e\n\u003cdd\u003e1 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated impulse withstand voltage (Uimp)\u003c\/dt\u003e\n\u003cdd\u003e4 kV\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.10 Temperature rise\u003c\/dt\u003e\n\u003cdd\u003eThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eBasic function\u003c\/dt\u003e\n\u003cdd\u003eCombined RCD\/MCB devices\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated current\u003c\/dt\u003e\n\u003cdd\u003e16 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnectable conductor cross section (multi-wired) - max\u003c\/dt\u003e\n\u003cdd\u003e25 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eType\u003c\/dt\u003e\n\u003cdd\u003eRCBO\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.2 Corrosion resistance\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSurge current capacity\u003c\/dt\u003e\n\u003cdd\u003e.25 kA\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.4 Resistance to ultra-violet (UV) radiation\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003e10.2.7 Inscriptions\u003c\/dt\u003e\n\u003cdd\u003eMeets the product standard's requirements.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated insulation voltage (Ui)\u003c\/dt\u003e\n\u003cdd\u003e440 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eGeneral\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eModel Code\u003c\/dt\u003e\n\u003cdd\u003ePKNM-16\/1N\/C\/003-A-MW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEAN\u003c\/dt\u003e\n\u003cdd\u003e4015082362171\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Length\/Depth\u003c\/dt\u003e\n\u003cdd\u003e80 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Height\u003c\/dt\u003e\n\u003cdd\u003e75 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Width\u003c\/dt\u003e\n\u003cdd\u003e35 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Weight\u003c\/dt\u003e\n\u003cdd\u003e.193 kg\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eWarranty\u003c\/dt\u003e\n\u003cdd\u003e1 year\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCompliances\u003c\/dt\u003e\n\u003cdd\u003eNOM-NYCE Marked\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCertifications\u003c\/dt\u003e\n\u003cdd\u003eUL Listed\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49087572246813,"sku":"DA-413075","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/eaton-236217-dropship-automation.webp?v=1753926516","url":"https:\/\/dropshipautomation.com\/products\/eaton-236217","provider":"Dropship Automation","version":"1.0","type":"link"}