{"product_id":"carlo-gavazzi-sh2dug24","title":"CARLO-GAVAZZI SH2DUG24","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003eSH2DUG24\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eDupline Specifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eVoltage\u003c\/dt\u003e\n\u003cdd\u003e8.2 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Dupline® voltage\u003c\/dt\u003e\n\u003cdd\u003e10 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMinimum Dupline® voltage\u003c\/dt\u003e\n\u003cdd\u003e4.5 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Dupline® current\u003c\/dt\u003e\n\u003cdd\u003e450 mA @ 25° 350 mA @ 40°\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminal\u003c\/dt\u003e\n\u003cdd\u003eD+ and D (Note: The Dupline® bus is located on the upper connector and also on the local bus connector on the right side of the module.)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eYellow LEDs Dupline bus\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eON\u003c\/dt\u003e\n\u003cdd\u003eThe Dupline® bus is working properly\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFlashing\u003c\/dt\u003e\n\u003cdd\u003eThere is a fault on the Dupline® bus\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOFF\u003c\/dt\u003e\n\u003cdd\u003eThe Dupline® bus is OFF or not connected.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eLEDs Indication\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eON\u003c\/dt\u003e\n\u003cdd\u003eSupply ON\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOFF\u003c\/dt\u003e\n\u003cdd\u003eSupply OFF\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOFF\u003c\/dt\u003e\n\u003cdd\u003eNo communication is present on the HS bus\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eON\u003c\/dt\u003e\n\u003cdd\u003eCommunication error on HS bus\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eFlashing\u003c\/dt\u003e\n\u003cdd\u003eCommunication OK on HS bus\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eHS Bus Specifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eBus type\u003c\/dt\u003e\n\u003cdd\u003eRS485 high speed bus\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtocol\u003c\/dt\u003e\n\u003cdd\u003eInternal proprietary protocol\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of slave\u003c\/dt\u003e\n\u003cdd\u003eMax 7\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection\u003c\/dt\u003e\n\u003cdd\u003eBy local bus (left and right connectors) or terminals GND, A(-), B(+). T1, T2: termination inputs. They have to be short-circuited on the last module of the network. See wiring diagrams.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAddressing method\u003c\/dt\u003e\n\u003cdd\u003eThe address of the SH2DUG24 is defined in the Sx tool, and then assigned to it by the Sx2WEB24 according to the SIN.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eSupply Specifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower supply\u003c\/dt\u003e\n\u003cdd\u003eOvervoltage cat. II (IEC 60664-1, par. 4.3.3.2)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational voltage\u003c\/dt\u003e\n\u003cdd\u003e15 to 24 VDC ± 20%\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperational voltage range\u003c\/dt\u003e\n\u003cdd\u003e10 to 30 VDC (ripple included)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated operational power\u003c\/dt\u003e\n\u003cdd\u003e6.5 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProtection for reverse polarity\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnection\u003c\/dt\u003e\n\u003cdd\u003e2xA1 (+) and 2xA2 (-)- (2 pairs of terminals internally connected)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower on delay\u003c\/dt\u003e\n\u003cdd\u003eTyp. 4 s\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePower off delay\u003c\/dt\u003e\n\u003cdd\u003e1 s\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49040567435549,"sku":"DA-285383","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/carlo-gavazzi-sh2dug24-dropship-automation.webp?v=1752901768","url":"https:\/\/dropshipautomation.com\/products\/carlo-gavazzi-sh2dug24","provider":"Dropship Automation","version":"1.0","type":"link"}