{"product_id":"abb-1sfl637001r6911","title":"ABB 1SFL637001R6911","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e1SFL637001R6911\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUPC\u003c\/dt\u003e\n\u003cdd\u003e73205002204050\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUNSPSC\u003c\/dt\u003e\n\u003cdd\u003e39121529\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\"grid items-center gap-x-4 px-4 \"\u003e\n\u003cdt\u003eETIM\u003c\/dt\u003e\n\u003cdd\u003e\u003cdl\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eGroup Code : EG000017\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eGroup Description : Low-voltage Industrial Components\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eClass Description : Power contactor, AC switching\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eClass Code : EC000066\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eVersion : 7\u003c\/dd\u003e\u003c\/div\u003e\n\u003c\/dl\u003e\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eDimensions\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Net Width\u003c\/dt\u003e\n\u003cdd\u003e210 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Net Depth \/ Length\u003c\/dt\u003e\n\u003cdd\u003e242 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Net Height\u003c\/dt\u003e\n\u003cdd\u003e283 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Net Weight\u003c\/dt\u003e\n\u003cdd\u003e13.6 kg\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eTechnical\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of Main Contacts NO\u003c\/dt\u003e\n\u003cdd\u003e3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of Main Contacts NC\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of Auxiliary Contacts NO\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of Auxiliary Contacts NC\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Operational Voltage\u003c\/dt\u003e\n\u003cdd\u003eMain Circuit 1000 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Frequency (f)\u003c\/dt\u003e\n\u003cdd\u003eMain Circuit 50 \/ 60 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConventional Free-air Thermal Current (Ith)\u003c\/dt\u003e\n\u003cdd\u003eacc. to IEC 60947-4-1, Open Contactors ˜ = 40°C 1050 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Operational Current AC-1 (Ie)\u003c\/dt\u003e\n\u003cdd\u003e(1000 V) 40°C 1000 A(1000 V) 55°C 875 A(1000 V) 70°C 720 A(690 V) 40°C 1050 A(690 V) 55°C 875 A(690 V) 70°C 720 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Operational Current AC-3 (Ie)\u003c\/dt\u003e\n\u003cdd\u003e(415 V) 55°C 750 A(440 V) 55°C 750 A(500 V) 55°C 750 A(690 V) 55°C 650 A(1000 V) 55°C 300 A(380 \/ 400 V) 55°C 750 A(220 \/ 230 \/ 240 V) 55°C 750\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Operational Power AC-3 (Pe)\u003c\/dt\u003e\n\u003cdd\u003e(415 V) 425 kW(440 V) 450 kW(500 V) 520 kW(690 V) 600 kW(1000 V) 400 kW(380 \/ 400 V) 400 kW(220 \/ 230 \/ 240 V) 220 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Breaking Capacity AC-3\u003c\/dt\u003e\n\u003cdd\u003e8 x Ie AC-3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Making Capacity AC-3\u003c\/dt\u003e\n\u003cdd\u003e10 x Ie AC-3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-Circuit Protective Devices\u003c\/dt\u003e\n\u003cdd\u003egG Type Fuses 1000 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Short-time Withstand Current Low Voltage (Icw)\u003c\/dt\u003e\n\u003cdd\u003eat 40°C Ambient Temp, in Free Air, from a Cold State 10 s 6400 Aat 40°C Ambient Temp, in Free Air, from a Cold State 15 min 1300 Aat 40°C Ambient Temp, in Free Air, from a Cold State 1 min 3500 Aat 40°C Ambient Temp, in Free Air, from a Cold State 1 s 7000 Aat 40°C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Breaking Capacity\u003c\/dt\u003e\n\u003cdd\u003ecos phi=0.45 (cos phi=0.35 for Ie \u0026gt; 100 A) at 440 V 7500 Acos phi=0.45 (cos phi=0.35 for Ie \u0026gt; 100 A) at 690 V 7000 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Electrical Switching Frequency\u003c\/dt\u003e\n\u003cdd\u003e(AC-1) 300 cycles per hour(AC-2 \/ AC-4) 60 cycles per hour(AC-3) 300 cycles per hour\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Operational Current DC-1 (Ie)\u003c\/dt\u003e\n\u003cdd\u003e(110 V) 1-Pole, 40°C 1050 A(110 V) 2 Poles in Series, 40°C 1050 A(220 V) 3 Poles in Series, 40°C 1050 A(600 V) 3 Poles in Series, 40°C 1050 A(850 V) 3 Poles in Series, 40°C 1050 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Operational Current DC-3 (Ie)\u003c\/dt\u003e\n\u003cdd\u003e(110 V) 1-Pole, 40°C 1050 A(110 V) 2 Poles in Series, 40°C 1050 A(220 V) 3 Poles in Series, 40°C 1050 A(600 V) 3 Poles in Series, 40°C 1050 A(850 V) 3 Poles in Series, 40°C 1050 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Operational Current DC-5 (Ie)\u003c\/dt\u003e\n\u003cdd\u003e(110 V) 1-Pole, 40°C 1050 A(110 V) 2 Poles in Series, 40°C 1050 A(220 V) 3 Poles in Series, 40°C 1050 A(600 V) 3 Poles in Series, 40°C 1050 A(850 V) 3 Poles in Series, 40°C 1050 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Insulation Voltage (Ui)\u003c\/dt\u003e\n\u003cdd\u003eacc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL\/CSA 600 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/dt\u003e\n\u003cdd\u003eMain Circuit 8 kV\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMechanical Durability\u003c\/dt\u003e\n\u003cdd\u003e3 million\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Mechanical Switching Frequency\u003c\/dt\u003e\n\u003cdd\u003e300 cycles per hour\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCoil Operating Limits\u003c\/dt\u003e\n\u003cdd\u003e(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ¸  ¤ 70°C)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Control Circuit Voltage (Uc)\u003c\/dt\u003e\n\u003cdd\u003e50 Hz 48 ... 130 V60 Hz 48 ... 130 VDC Operation 48 ... 130 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCoil Consumption\u003c\/dt\u003e\n\u003cdd\u003eHolding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 5 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 1100 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 1100 V·APull-in at Max. Rated Control Circuit Voltage DC 1020 V·A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperate Time\u003c\/dt\u003e\n\u003cdd\u003eBetween Coil De-energization and NC Contact Closing 50 ... 70 msBetween Coil De-energization and NO Contact Opening 53 ... 73 msBetween Coil Energization and NC Contact Opening 45 ... 115 msBetween Coil Energization and NO Contact Closing 50 ... 120 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnecting Capacity Main Circuit\u003c\/dt\u003e\n\u003cdd\u003eBar 52 mm²Rigid Al-Cable 3x185 mm²Rigid Cu-Cable 300 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnecting Capacity Auxiliary Circuit\u003c\/dt\u003e\n\u003cdd\u003eFlexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 1 x 1 .... 4 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDegree of Protection\u003c\/dt\u003e\n\u003cdd\u003eacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminal Type\u003c\/dt\u003e\n\u003cdd\u003eMain Circuit: Bars\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eClassifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eObject Classification Code\u003c\/dt\u003e\n\u003cdd\u003eQ\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eETIM 4\u003c\/dt\u003e\n\u003cdd\u003eEC000066 - Magnet contactor, AC-switching\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eETIM 5\u003c\/dt\u003e\n\u003cdd\u003eEC000066 - Magnet contactor, AC-switching\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEClass\u003c\/dt\u003e\n\u003cdd\u003eV11.0 : 27371003\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIDEA Granular Category Code (IGCC)\u003c\/dt\u003e\n\u003cdd\u003e4758 \u0026gt;\u0026gt; Iec Contactors\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eE-Number (Norway)\u003c\/dt\u003e\n\u003cdd\u003e4115299\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eE-Number (Sweden)\u003c\/dt\u003e\n\u003cdd\u003e3228364\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironmental\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature\u003c\/dt\u003e\n\u003cdd\u003eClose to Contactor Fitted with Thermal O\/L Relay (0.85 ... 1.1 Uc) -25 ... 50°CClose to Contactor without Thermal O\/L Relay (0.85 ... 1.1 Uc) -40 ... 70°CClose to Contactor for Storage -40 ... 70°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Operating Altitude Permissible\u003c\/dt\u003e\n\u003cdd\u003eWithout Derating 3000 m\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eResistance to Shock acc. to IEC 60068-2-27\u003c\/dt\u003e\n\u003cdd\u003eShock Direction: A 5 gShock Direction: B1 5 gShock Direction: B2 5 gShock Direction: C1 5 gShock Direction: C2 5 g\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRoHS Status\u003c\/dt\u003e\n\u003cdd\u003eFollowing EU Directive 2011\/65\/EU and Amendment 2015\/863 July 22, 2019\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eTechnical UL\/CSA\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNEMA Size\u003c\/dt\u003e\n\u003cdd\u003e7\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHorsepower Rating NEMA\u003c\/dt\u003e\n\u003cdd\u003e(230 V AC) Three Phase 300 Hp(460 V AC) Three Phase 600 Hp(575 V AC) Three Phase 600 Hp\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Operating Voltage UL\/CSA\u003c\/dt\u003e\n\u003cdd\u003eMain Circuit 1000 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eGeneral Use Rating UL\/CSA\u003c\/dt\u003e\n\u003cdd\u003e(1000 V AC) 900 A(600 V AC) 900 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHorsepower Rating UL\/CSA\u003c\/dt\u003e\n\u003cdd\u003e(200 V AC) Three Phase 250 hp(208 V AC) Three Phase 250 hp(220 ... 240 V AC) Three Phase 300 hp(440 ... 480 V AC) Three Phase 600 hp(550 ... 600 V AC) Three Phase 700 hp\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eOrdering\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMinimum Order Quantity\u003c\/dt\u003e\n\u003cdd\u003e1 piece\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCustoms Tariff Number\u003c\/dt\u003e\n\u003cdd\u003e85364900\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49131256316189,"sku":"DA-603145","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/dropship-automation_d9cd9958-6034-4f03-a49f-ef7db4868c84.webp?v=1732596359","url":"https:\/\/dropshipautomation.com\/products\/abb-1sfl637001r6911","provider":"Dropship Automation","version":"1.0","type":"link"}