{"product_id":"abb-1sfl527102r1411","title":"ABB 1SFL527102R1411","description":"\u003ch2 class=\"\"\u003eAdditional Information\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003ePart Number\u003c\/dt\u003e\n\u003cdd\u003e1SFL527102R1411\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUPC\u003c\/dt\u003e\n\u003cdd\u003e73205005036900\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eUNSPSC\u003c\/dt\u003e\n\u003cdd\u003e39121529\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\"grid items-center gap-x-4 px-4 \"\u003e\n\u003cdt\u003eETIM\u003c\/dt\u003e\n\u003cdd\u003e\u003cdl\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eGroup Code : EG000017\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eGroup Description : Low-voltage Industrial Components\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eClass Description : Power contactor, AC switching\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eClass Code : EC000066\u003c\/dd\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cdd\u003eVersion : 7\u003c\/dd\u003e\u003c\/div\u003e\n\u003c\/dl\u003e\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eDimensions\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Net Width\u003c\/dt\u003e\n\u003cdd\u003e140 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Net Depth \/ Length\u003c\/dt\u003e\n\u003cdd\u003e152.5 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Net Height\u003c\/dt\u003e\n\u003cdd\u003e195.6 mm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eProduct Net Weight\u003c\/dt\u003e\n\u003cdd\u003e3.3 kg\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eTechnical\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of Main Contacts NO\u003c\/dt\u003e\n\u003cdd\u003e4\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of Main Contacts NC\u003c\/dt\u003e\n\u003cdd\u003e0\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of Auxiliary Contacts NO\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eNumber of Auxiliary Contacts NC\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Operational Voltage\u003c\/dt\u003e\n\u003cdd\u003eMain Circuit 1000 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Frequency (f)\u003c\/dt\u003e\n\u003cdd\u003eMain Circuit 50 Hz\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConventional Free-air Thermal Current (Ith)\u003c\/dt\u003e\n\u003cdd\u003eacc. to IEC 60947-4-1, Open Contactors ˜ = 40°C 350 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Operational Current AC-1 (Ie)\u003c\/dt\u003e\n\u003cdd\u003e(1000 V) 40°C 275 A(1000 V) 60°C 250 A(1000 V) 70°C 200 A(690 V) 40°C 350 A(690 V) 60°C 300 A(690 V) 70°C 240 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Operational Current AC-3 (Ie)\u003c\/dt\u003e\n\u003cdd\u003e(415 V) 55°C 205 A(440 V) 55°C 205 A(380 \/ 400 V) 55°C 205 A(220 \/ 230 \/ 240 V) 55°C 205\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Operational Power AC-3 (Pe)\u003c\/dt\u003e\n\u003cdd\u003e(415 V) 110 kW(440 V) 132 kW(380 \/ 400 V) 110 kW(220 \/ 230 \/ 240 V) 55 kW\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Breaking Capacity AC-3\u003c\/dt\u003e\n\u003cdd\u003e8 x Ie AC-3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Making Capacity AC-3\u003c\/dt\u003e\n\u003cdd\u003e10 x Ie AC-3\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eShort-Circuit Protective Devices\u003c\/dt\u003e\n\u003cdd\u003egG Type Fuses 400 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Short-time Withstand Current Low Voltage (Icw)\u003c\/dt\u003e\n\u003cdd\u003eat 40°C Ambient Temp, in Free Air, from a Cold State 10 s 1640 Aat 40°C Ambient Temp, in Free Air, from a Cold State 15 min 350 Aat 40°C Ambient Temp, in Free Air, from a Cold State 1 min 670 Aat 40°C Ambient Temp, in Free Air, from a Cold State 1 s 2050 Aat 40°C Ambient Temp, in Free Air, from a Cold State 30 s 947 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Breaking Capacity\u003c\/dt\u003e\n\u003cdd\u003ecos phi=0.45 (cos phi=0.35 for Ie \u0026gt; 100 A) at 440 V 3500 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Electrical Switching Frequency\u003c\/dt\u003e\n\u003cdd\u003e(AC-1) 300 cycles per hour\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Insulation Voltage (Ui)\u003c\/dt\u003e\n\u003cdd\u003eacc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL\/CSA 600 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/dt\u003e\n\u003cdd\u003eMain Circuit 8 kV\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMechanical Durability\u003c\/dt\u003e\n\u003cdd\u003e5 million\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Mechanical Switching Frequency\u003c\/dt\u003e\n\u003cdd\u003e300 cycles per hour\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCoil Operating Limits\u003c\/dt\u003e\n\u003cdd\u003e(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ¸  ¤ 70°C)\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRated Control Circuit Voltage (Uc)\u003c\/dt\u003e\n\u003cdd\u003e50 Hz 250 ... 500 V60 Hz 250 ... 500 VDC Operation 250 ... 500 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCoil Consumption\u003c\/dt\u003e\n\u003cdd\u003eHolding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·AHolding at Max. Rated Control Circuit Voltage DC 3.9 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 260 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 260 V·APull-in at Max. Rated Control Circuit Voltage DC 230 W\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eOperate Time\u003c\/dt\u003e\n\u003cdd\u003eBetween Coil De-energization and NO Contact Opening 45 ... 80 msBetween Coil Energization and NO Contact Closing 25 ... 60 ms\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnecting Capacity Main Circuit\u003c\/dt\u003e\n\u003cdd\u003eFlexible 1 x 6 ... 120 mm²Rigid Al-Cable 1 x 95 ... 185 mm²Rigid Cu-Cable 1 x 6 ... 150 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eConnecting Capacity Auxiliary Circuit\u003c\/dt\u003e\n\u003cdd\u003eFlexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eDegree of Protection\u003c\/dt\u003e\n\u003cdd\u003eacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eTerminal Type\u003c\/dt\u003e\n\u003cdd\u003eMain Circuit: Bars\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEco Transparency\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEnvironmental Product Declaration - EPD\u003c\/dt\u003e\n\u003cdd\u003e1SFC100095D0201\u003c\/dd\u003e\n\u003c\/div\u003e\u003c\/dl\u003e \u003ch2 class=\"\"\u003eClassifications\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eObject Classification Code\u003c\/dt\u003e\n\u003cdd\u003eQ\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eETIM 4\u003c\/dt\u003e\n\u003cdd\u003eEC000066 - Magnet contactor, AC-switching\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eETIM 5\u003c\/dt\u003e\n\u003cdd\u003eEC000066 - Magnet contactor, AC-switching\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEClass\u003c\/dt\u003e\n\u003cdd\u003eV11.0 : 27371003\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eIDEA Granular Category Code (IGCC)\u003c\/dt\u003e\n\u003cdd\u003e4758 \u0026gt;\u0026gt; Iec Contactors\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eE-Number (Finland)\u003c\/dt\u003e\n\u003cdd\u003e3707217\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eE-Number (Norway)\u003c\/dt\u003e\n\u003cdd\u003e3210337\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eE-Number (Sweden)\u003c\/dt\u003e\n\u003cdd\u003e3210337\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eEnvironmental\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eAmbient Air Temperature\u003c\/dt\u003e\n\u003cdd\u003eClose to Contactor Fitted with Thermal O\/L Relay (0.85 ... 1.1 Uc) -25 ... 50°CClose to Contactor without Thermal O\/L Relay (0.85 ... 1.1 Uc) -40 ... 70°CClose to Contactor for Storage -40 ... 70°C\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Operating Altitude Permissible\u003c\/dt\u003e\n\u003cdd\u003eWithout Derating 3000 m\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eRoHS Status\u003c\/dt\u003e\n\u003cdd\u003eFollowing EU Directive 2011\/65\/EU and Amendment 2015\/863 July 22, 2019\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eCircular Value\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eABB EcoSolutions\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCircular Design Principles Recyclability Rate\u003c\/dt\u003e\n\u003cdd\u003eDesign for Closing Resource Loops - Standard EN45555 - 79.2 %\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eEnd of Life Instructions\u003c\/dt\u003e\n\u003cdd\u003e1SFC100112M0001\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eGroup Waste to Landfill Target\u003c\/dt\u003e\n\u003cdd\u003eNon-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eImproved Resource Efficiency for Customers\u003c\/dt\u003e\n\u003cdd\u003eProduct Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eSustainable Material Content\u003c\/dt\u003e\n\u003cdd\u003eRecycled Metal - 35 %\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eTechnical UL\/CSA\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMaximum Operating Voltage UL\/CSA\u003c\/dt\u003e\n\u003cdd\u003eMain Circuit 1000 V\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eGeneral Use Rating UL\/CSA\u003c\/dt\u003e\n\u003cdd\u003e(600 V AC) 250 A\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eHorsepower Rating UL\/CSA\u003c\/dt\u003e\n\u003cdd\u003e(200 ... 208 V AC) Three Phase 30 Hp(200 V AC) Three Phase 60 hp(208 V AC) Three Phase 60 hp(220 ... 240 V AC) Three Phase 30 Hp(220 ... 240 V AC) Three Phase 75 hp(440 ... 480 V AC) Three Phase 75 Hp(440 ... 480 V AC) Three Phase 150 hp(550 ... 600 V AC) Three Phase 100 Hp(550 ... 600 V AC) Three Phase 200 hp\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e \u003ch2 class=\"\"\u003eOrdering\u003c\/h2\u003e\u003cdl class=\"text-sm\"\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eMinimum Order Quantity\u003c\/dt\u003e\n\u003cdd\u003e1 piece\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" \"\u003e\n\u003cdt\u003eCustoms Tariff Number\u003c\/dt\u003e\n\u003cdd\u003e85364900\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e ","brand":"Dropship Automation","offers":[{"title":"Default Title","offer_id":49151084560669,"sku":"DA-655306","price":999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/1056\/1565\/files\/dropship-automation_811a10ad-732d-473b-9490-00c334e66e93.webp?v=1732791518","url":"https:\/\/dropshipautomation.com\/products\/abb-1sfl527102r1411","provider":"Dropship Automation","version":"1.0","type":"link"}